Rishabh Rish Xmer 140-100H (45) 2000/5 Class 1 Series Current Transformer
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 140-100H (45) 2000/5 Class 1
Technology
AC Current Transformer
Ratio
2000/5
Aperture Size
⌀ 65mm or 85 x 12mm Busbar
VA Rating
45VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2000Amp x 1.2
Termination Style
Screw
Unit Weight
1.2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh CT 100/5 Class 0.5 2.5VA 50/21 (50), Current Transformer, ⌀ 21mm or 20x10mm Busbar
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 100/5 Class 0.5 2.5VA 50/21 (50)
Technology
AC Current Transformer
Ratio
100/5
Aperture Size
⌀ 21mm or 20x10mm Busbar
VA Rating
2.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh Shunt 5A/75mV DC Current Shunt, 75mV output, Form B Class 0.5
Features
Low Cost
Instantaneous measurement
Applications
Industrial Electrical Installatons
Feedback Control
DC Current Measurement
Specification
Rishabh Part Number
Shunt 5A/75mV
Nominal Current Ipn (DC)
up to 10 Amp
Overload Capacity
1.2 x Ipn continuous (5 x Ipn 5 seconds)
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 65°C
Standards
DIN EN 60 051, DIN EN 50 022-35
Unit Weight
up to 7kg
Factory Pack Qty
1
Datasheet
Product Datasheet
HVBD4AXR Rev J, Hermetic Battery Switch with Red Handle, SPST 1 x 400 Amp 1000VDC, Flange Mount 70mm Wide, M10 Terminations, OHSA (LOTO)
DC battery switches are designed to be placed in between the battery and load. Suitable for any medium voltage DC application which requires up to 400Amp Continuous or 2000 Amp Overload for 1 minute.
Features :
1 Pole Disconnect
Suitable for 1000VDC Battery/Solar Isolation
Standards :
OSHA
IP65 (Front) IP20 (Terminals)
CE Approved
Specification
Rincon Power Part Number
HVBD4AXR Rev J (1000VDC only)
Functions
1 Pole DC SPST Disconnect Switch, ON/OFF Red Handle
Nominal Voltage
1000VDC (5000VDC 1 min)
Nominal Current
1 x 400 Amp DC
Rated Impulse Voltage
5kV (1 min)
Rated Insulation Voltage
1000VDC
Short Circuit Current
2kA (1 min)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
120 x 84.3mm
Termination
M10 Stud
Mounting
100mm
Standards
OSHA, CE
Weight
425g
Enclosure Material
PA GF
Factory Pack Qty
15
Datasheet
Product Datasheet
Rincon Power Product Portfolio
Rishabh Shunt 300A/75mV DC Current Shunt, 75mV output, Form B Class 0.5
Features
Low Cost
Instantaneous measurement
Applications
Industrial Electrical Installatons
Feedback Control
DC Current Measurement
Specification
Rishabh Part Number
Shunt 300A/75mV
Nominal Current Ipn (DC)
up to 300 Amp
Overload Capacity
1.2 x Ipn continuous (5 x Ipn 5 seconds)
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 65°C
Standards
DIN EN 60 051, DIN EN 50 022-35
Unit Weight
up to 7kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
40mA Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-400-40mA
Technology
Split Core AC Current Transformer
Ratio
400/040 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
.40 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
400Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Rishabh CT 200/5 Class 1 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA HIGH BURDEN, Class 0.5, 36mm Aperture or 11x41mm Busbar
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 200/5 Class 1 15VA 86/40 (45)
Technology
AC Current Transformer
Ratio
200/5
Aperture Size
36mm or 11x41mm Busbar
VA Rating
15VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics FESCT-6000-4000-0.333V, 4000Amp 0.333V Class 1 Measurement Split Core CT's, w/terminals, 153x157mm Aperture
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
FESCT-6000-4000-0.333V
Technology
Split Core AC Current Transformer
Ratio
4000/0.333V
Aperture Size
153x157mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
4000Amp x 1.2
Termination Style
Terminals
Unit Weight
3000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Rish Xmer 74-20 (45) 100/5 Class 0.2S, 1.5VA, 21mm Aperture
Features
High Accuravcy Class 0.2S
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 74-20 (45) 100/5 Class 0.2S
Technology
AC Current Transformer
Ratio
800/5
Aperture Size
21x11mm
VA Rating
1.5VA
Accuracy Class
Class 0.2S
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
9
Datasheet
Product Datasheet
FP040080P, 400/5 Amp Split Core CT, Class 0.5 1.5VA Series Clip On Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP040080P
Technology
Split Core AC Clip On Current Transformer
Ratio
400/5
Aperture Size
50 x 80mm
VA Rating
1.5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
400Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Fastron Electronics SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F50-200-5A
Technology
Split Core AC Current Transformer
Ratio
200/5 Amp
Aperture Size
ø 50 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Rishabh 3PH105-21(40) 200, Class 1 1.5VA, 200 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
3PH105-21(40) 200
Technology
AC Current Transformer
Ratio
200/5
Aperture Size
20 x 24mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet