Iskra Doo MI 454, Potentiometer and Tap Position Programmable Transducer, Class 0.5, Universal 20 - 300VDC/40 to 276VAC 40 to 70Hz, Aux Voltage 57.74V,100V,230V,400V,500VAC
Class 0.5 (EN 60688)
Programable DC Voltage Output 0-1V to 0-10V @ 20mA
Programmable DC Current Output 0-1mA to 0-5mA, 0-5mA to 0-20mA @ 15V
Features :
Measurement of up to 500VAC
Universal Supply 20 - 300VDC/40 to 276VAC 40 to 70Hz
Accuracy class 0.5
Input frequency 40-70Hz
Specification
Iskra Doo Part Number
MI454
Functions
Single Phase AC Voltage Transducer
Supply Voltage
Self Powered
Nominal Measurement Range
0-500VAC
Maximum Measurement Range
0-600VAC
Output
0-20mA/0-5mA
Tariff Input
N/A
Accuracy
Class 0.5
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Comms
N/
Weight
340g
Enclosure Material
UL94
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Iskra Doo MT406-54 Series Single Phase AC Voltage Transducer, Fixed zero and span
Class 0.5 (EN 60688)
0-20mA analogue Output
Average RMS values of voltage
Features :
Measurement of up to 132VAC
Self Powered
Accuracy class 0.5
Input frequency 50/60Hz
Specification
Iskra Doo Part Number
MT406-54
Functions
Single Phase AC Voltage Transducer
Supply Voltage
Self Powered
Nominal Measurement Range
0-110VAC
Maximum Measurement Range
0-132VAC
Output
0-20mA
Tariff Input
N/A
Accuracy
Class 0.5
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Comms
N/
Weight
340g
Enclosure Material
UL94
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Iskra Doo MT406-24 Series Single Phase AC Voltage Transducer, Fixed zero and span
Class 0.5 (EN 60688)
0-20mA analogue Output
Average RMS values of voltage
Features :
Measurement of up to 76.2VAC
Self Powered
Accuracy class 0.5
Input frequency 50/60Hz
Specification
Iskra Doo Part Number
MT406-24
Functions
Single Phase AC Voltage Transducer
Supply Voltage
Self Powered
Nominal Measurement Range
0-63.5VAC
Maximum Measurement Range
0-76.2VAC
Output
0-20mA
Tariff Input
N/A
Accuracy
Class 0.5
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Comms
N/
Weight
340g
Enclosure Material
UL94
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Oztherm F940-A-60VAC-C1, AC Average RMS Voltage Transducer, 9-36VDC Supply, 0-60Volt, 4-20mA Measurement Output
Made to order, Delivery typically within 2 weeks
Fastron Electronics GTD-D-C-SP03, 0-300VDC Voltage Transducer/Transmitter, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-D-C-SP03
Control Output
4-20mA
Input
0 - 300VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rishabh Rish Con-V(500)-F-H-O1A1-O200-D-Z-Z, AC Voltage Transducer, Input Programmable True RMS 50Hz 57-500VAC Full Scale, 0-20mA, 60-300VAC Supply, with Display
Digital output setting 0-20mA/4-20mA/0-10V
Dual output version available
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con-V(500)-F-H-O1A1-O200-D-Z-Z
Measurement Output
4-20mA/0-20mA/0-10V User Selectable
Input
57 - 500VAC 50/60Hz
Overlaod (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Technical Support
Rish Con P setup procedure blog
Iskra Doo MT406-11 Series Single Phase AC Voltage Transducer, Fixed zero and span
Class 0.5 (EN 60688)
0-1mA analogue output for Moving Coil Voltmeter
Average RMS values of voltage
Features :
Measurement of up to 69.25VAC
Self powered
Accuracy class 0.5
Input frequency 50/60Hz
Specification
Iskra Doo Part Number
MT406-11
Functions
Single Phase AC Voltage Transducer
Supply Voltage
Self Powered
Nominal Measurement Range
57.7VAC
Maximum Measurement Range
69.25VAC
Output
0-1mA
Tariff Input
N/A
Accuracy
Class 0.5
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Comms
N/
Weight
340g
Enclosure Material
UL94
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
MiQen Setting Software
Fastron FDV-24-420-24, DC Voltage Transducer, Din Rail Mount, 0-24VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-24-420-24
Analogue Output
4-20mA
Input
0 - 24VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-150-V05-12, DC Voltage Transducer, Din Rail Mount, 0-150VDC, 0-5V output, 12VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-V05-12
Analogue Output
0-5V
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
12VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-50-V10-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-V10-24
Analogue Output
0-10V
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-500-V10-24, DC Voltage Transducer, Din Rail Mount, 0-500VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-500-V10-24
Analogue Output
0-10V
Input
0 - 500VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-50-V05-12, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 0-5V output, 12VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-V05-12
Analogue Output
0-5V
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
12VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet