Electronicon

111 products

  • 1301A.C09-12.5 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 6, 12, 15 kVar, 200,000 Operations, AC-6B

    1301A.C09-12.5 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 6, 12, 15 kVar, 200,000 Operations, AC-6B

    Out of stock

    Free Aus Post Shipping for $300 Spend

    1301A.C09-12.5 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 6, 12, 15 kVar, 200,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Electronicon Part Number 1301A.C09-12.5 + 1302A.C09-00.0 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 6kVar/Amp @230VAC, 12kVar/Amp@480VAC, 15kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 1 x NC Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 15,000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $73.00
    $86.14 inclGST

  • 1301A.C09-16.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 12, 16, 20 kVar, 200,000 Operations, AC-6B

    1301A.C09-16.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 12, 16, 20 kVar, 200,000 Operations, AC-6B

    Out of stock

    Free Aus Post Shipping for $300 Spend

    1301A.C09-16.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 12, 16, 20 kVar, 200,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Electronicon Part Number 1301A.C09-16.0 + 1302A.C09-00.0 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 12kVar/Amp @230VAC, 16kVar/Amp@480VAC, 20kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 1 x NC Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 15,000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $93.00
    $109.74 inclGST

  • 1301A.C09-20.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 15, 20, 25 kVar, 200,000 Operations, AC-6B

    1301A.C09-20.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 15, 20, 25 kVar, 200,000 Operations, AC-6B

    Out of stock

    Free Aus Post Shipping for $300 Spend

    1301A.C09-20.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 15, 20, 25 kVar, 200,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Electronicon Part Number 1301A.C09-20.0 + 1302A.C09-00.0 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 15kVar/Amp @230VAC, 20kVar/Amp@480VAC, 25kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 1 x NC Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 15,000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $119.00
    $140.42 inclGST

  • 1301A.C09-25.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 30 kVar, 200,000 Operations, AC-6B

    1301A.C09-25.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 30 kVar, 200,000 Operations, AC-6B

    Out of stock

    Free Aus Post Shipping for $300 Spend

    1301A.C09-25.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 30 kVar, 200,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Electronicon Part Number 1301A.C09-25.0 + 1302A.C09-00.0 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 12.5kVar/Amp @230VAC, 25kVar/Amp@480VAC, 30kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 1 x NC Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 15,000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $139.00
    $164.02 inclGST

  • 1301A.C09-50.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B

    1301A.C09-50.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B

    Out of stock

    Free Aus Post Shipping for $300 Spend

    1301A.C09-50.0 + 1302A.C09-00.0, Capacitor Duty Contactor 240/480/600VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Electronicon Part Number 1301A.C09-50.0 + 1302A.C09-00.0 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 27kVar/Amp @230VAC, 50kVar/Amp@480VAC, 50kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 1 x NC Trip Delay Time 2-10ms Electrical Life 100,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 15,000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $289.00
    $341.02 inclGST

  • 265.266-511100 / 221K02 24.1Kvar 480V 50Hz, 24.1kvar 480V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 111uF, Internal Discharge Resistors Included

    265.266-511100 / 221K02 24.1Kvar 480V 50Hz, 24.1kvar 480V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 111uF, Internal Discharge Resistors Included

    Out of stock

    Heavy Item - No Free Shipping

    Electronicon 265.266-511100 / 221K02 24.1Kvar 480V 50Hz, 24.1kvar 480V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 111uF, Internal Discharge Resistors Included Characteristics and utility 241kVar @ 480V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Gas Filled Lightweight Construction Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number 265.266-511100 / 221K02 24.1Kvar 480V 50Hz Technology Gas Filled, Low Loss, Self Healing Dimensions 75 x 230(+32)mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 480V @ 50Hz Kvar 20 Kvar Capacitance 3 x 111uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 3 x 52 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Approvals UL 810, CSA C22.2 No.90 Unit Weight 1.5kg Factory Pack Quantity 30   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog

    Out of stock

    Heavy Item - No Free Shipping

    $229.00
    $270.22 inclGST

  • 275.111-10181 - Discharge Resistor for 276 series Single Phase PFC Capacitors

    275.111-10181 - Discharge Resistor for 276 series Single Phase PFC Capacitors

    20 pcs in stock

    Electronicon 275.111-10181 - Discharge Resistor for 276 series Single Phase PFC Capacitors Datasheet Product Datasheet Application Notes Blog on Discharge Resistor Selection

    20 pcs in stock

    $3.50
    $4.13 inclGST

  • 275.156-803800, 10kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 85 x 230(+32 +5/-2)mm Gas Filled, 3 x 38.5uF 275.186-709600/221K02 25kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 116 x 245mm Dry Type-Power Factor Correction Capacitor-Electronicon-Fastron Electronics Store

    275.156-803800, 10kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 85 x 230(+32 +5/-2)mm Gas Filled, 3 x 38.5uF

    Out of stock

    Heavy Item - No Free Shipping

     Electronicon 275.156-803800, 10kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 85 x 230(+32 +5/-2)mm Gas Filled, 3 x 38.5uF Characteristics and utility 10kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Gas Filled Lightweight Construction Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number 275.156-803800 Technology Gas Filled, Low Loss, Self Healing Dimensions 85 x 230(+32)mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 10 Kvar Capacitance 3 x 38.5uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 3 x 11 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Approvals UL 810, CSA C22.2 No.90 Unit Weight 1.6kg Factory Pack Quantity 30   Datasheet Product Datasheet Application Notes & Brand Comparison Discharge Resistor Usage Power Factor Correction Blog 3 Phase Power Factor Correction Capacitor Comparison Chart

    Out of stock

    Heavy Item - No Free Shipping

    $209.00
    $246.62 inclGST

  • 275.166-607700 / 221K02 20Kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 77uF, FEED THROUGH TERMINALS, Requires Discharge Resistors

    275.166-607700 / 221K02 20Kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 77uF, FEED THROUGH TERMINALS, Requires Discharge Resistors

    Out of stock

    Heavy Item - No Free Shipping

    Electronicon 275.166-607700 / 221K02 20Kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 77uF, FEED THROUGH TERMINALS, Requires Discharge Resistors Characteristics and utility 20kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Gas Filled Lightweight Construction Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number 275.166-607700 / 221K02 20Kvar 525V 50Hz Technology Gas Filled, Low Loss, Self Healing Dimensions 95 x 230(+32)mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 20 Kvar Capacitance 3 x 77uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 3 x 22 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Approvals UL 810, CSA C22.2 No.90 Unit Weight 1.5kg Factory Pack Quantity 30   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog

    Out of stock

    Heavy Item - No Free Shipping

    $239.00
    $282.02 inclGST

  • 275.166-804800, 12.5kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 48.1uF 275.186-709600/221K02 25kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 116 x 245mm Dry Type-Power Factor Correction Capacitor-Electronicon-Fastron Electronics Store

    275.166-804800, 12.5kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 48.1uF

    Out of stock

    Heavy Item - No Free Shipping

    Electronicon 275.166-804800, 12.5kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 48.1uF Characteristics and utility 12.5kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Gas Filled Lightweight Construction Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number 275.166-804800 Technology Gas Filled, Low Loss, Self Healing Dimensions 95 x 230(+32)mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 12.5 Kvar Capacitance 3 x 48.1uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 3 x 13.7 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Approvals UL 810, CSA C22.2 No.90 Unit Weight 1.6kg Factory Pack Quantity 30   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog

    Out of stock

    Heavy Item - No Free Shipping

    $209.00
    $246.62 inclGST

  • 275.168-609600 / 221K02 25kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 245(+33 +/-2)mm Gas Filled, Requires Discharge Resistor, 3 x 96uF, Can Replace Epcos MKP525-D-25.0 [Double Sided Terminals] 275.168-609600 / 221K02 25kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 245(+33 +/-2)mm Gas Filled, Requires Discharge Resistor, 3 x 96uF, Can Replace Epcos MKP525-D-25.0 [Double Sided Terminals]

    275.168-609600 / 221K02 25kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 245(+33 +/-2)mm Gas Filled, Requires Discharge Resistor, 3 x 96uF, Can Replace Epcos MKP525-D-25.0 [Double Sided Terminals]

    188 pcs in stock

    Electronicon 275.168-609600 / 221K02 25kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 245(+33 +/-2)mm Gas Filled, Requires Discharge Resistor, 3 x 96uF, Can Replace Epcos MKP525-D-25.0 [Double Sided Terminals] Characteristics and utility 25kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Gas Filled Lightweight Construction Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number 275.168-609600 / 221K02 25kvar 525V 50Hz Technology Gas Filled, Low Loss, Self Healing Dimensions 95 x 245(+33 +/-2)mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 25 Kvar Capacitance 3 x 96.2uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 3 x 45 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Approvals UL 810, CSA C22.2 No.90 Unit Weight 2.3kg Factory Pack Quantity 25 Datasheet Product Datasheet Can Replace Epcos MKP525-D-25.0 Application Notes Discharge Resistor Usage Power Factor Correction Blog

    188 pcs in stock

    $244.00
    $287.92 inclGST

  • 275.186-516600/221K02 36kvar 480V 50Hz, Power Factor Correction Capacitor, 3 Phase, 116 x 230(+32)mm Gas Filled, 3 x 166uF, Requires Discharge Resistor 275.186-516600/221K02 36kvar 480V 50Hz, Power Factor Correction Capacitor, 3 Phase, 116 x 230(+32)mm Gas Filled, 3 x 166uF, Requires Discharge Resistor

    275.186-516600/221K02 36kvar 480V 50Hz, Power Factor Correction Capacitor, 3 Phase, 116 x 230(+32)mm Gas Filled, 3 x 166uF, Requires Discharge Resistor

    139 pcs in stock

    Electronicon 275.186-516600/221K02 36kvar 480V 50Hz, Power Factor Correction Capacitor, 3 Phase, 116 x 230(+32)mm Gas Filled, 3 x 166uF, Requires Discharge Resistor Characteristics and utility 36kVar @ 480V @ 50 Hz  (25kvar @ 415VAC)10. 0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Gas Filled Lightweight Construction Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number 275.186-516600/221K02 36kvar 480V 50Hz Technology Gas Filled, Low Loss, Self Healing Dimensions 116 x 230(+32)mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 480V @ 50Hz Kvar 36 Kvar @ 525V   25Kvar @ 480VAC Capacitance 3 x 166uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 3 x 45 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Approvals UL 810, CSA C22.2 No.90 Unit Weight 2.3kg Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog

    139 pcs in stock

    $297.00
    $350.46 inclGST

Login

Forgot your password?

Don't have an account yet?