Trent AV-FGM6S-160-230V 100A, Shunt Trip Release, Left Side Mount for Moulded Case Circuit Breaker (MCCB) Frame Size 160Â
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Shunt Trip Release, Left Side Mount
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
AV-FGM6S-160-230V 100A
Functions
MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent UV-FGM6S-250-400V, Undervoltage Release, Right Side Mount for Moulded Case Circuit Breaker (MCCB) Frame Size 250Â
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Undervoltage Release, Right Side Mount
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
UV-FGM6S-250-400V
Functions
MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent UV-FGM6S-160-400V 100A, Undervoltage Release, Right Side Mount for Moulded Case Circuit Breaker (MCCB) Frame Size 160Â
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Undervoltage Release, Right Side Mount
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
UV-FGM6S-160-400V 100A
Functions
MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent UV-FGM6S-250-230V, Undervoltage Release, Right Side Mount for Moulded Case Circuit Breaker (MCCB) Frame Size 250
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Undervoltage Release, Right Side Mount
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
UV-FGM6S-250-230V
Functions
MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent UV-FGM6S-160-230V 100A, Undervoltage Release, Right Side Mount for Moulded Case Circuit Breaker (MCCB) Frame Size 160Â
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Undervoltage Release, Right Side Mount
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
UV-FGM6S-160-230V 100A
Functions
MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6-630, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6-630
Functions
3 Pole MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6-3P-400, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6-3P-400
Functions
3 Pole MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6-3P-250, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6-3P-250
Functions
3 Pole MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6-3P-160, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 160, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6-3P-160
Functions
3 Pole MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
FK-3-150, aR Type Fuse Kit for 120-150 Amp F330, F430, F431 Three Phase Power Controller or VSD Drives
Contains:
3 x 150BF Trent Fuses
6 x M6x25mm Isolated Standoffs
Mounting HaRdwaRe
Datasheet
Product Datasheet
Cross Reference ChaRt
Insulated Standoffs
FK-3-100, aR Type Fuse Kit for 75-100 Amp F330, F430, F431 Three Phase Power Controller or VSD Drives
Contains:
3 x 100AF Trent Fuses
6 x M5x25mm Isolated Standoffs
Mounting HaRdwaRe
Datasheet
Product Datasheet
Cross Reference ChaRt
Insulated Standoffs
TRENT TGD-1PL C 20-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 20 Amp, 10kA, 250VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
BidirectionalÂ
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB,RCM (Pending)
Specification
TRENT Part Number
TGD-1PL C 20-10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
250VDC @ 50/60Hz
Nominal Current Range
20 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Â
Datasheet
Product Datasheet