Trent I^2t (aR) Blade Style Semiconductor Fuse, 500 Amp, 690VAC, Square Body, Size 1*/80, DIN 43 653, 200kA (78mm Hole Centers) F170M3014
Features
Square Body, Size 1*/80, DIN 43 653
Wide Range of I^2t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I^2t
Short Circuit Protection
DC or AC Motor I^2t Protection
Battery Fuse
Specification
Trent Part Number
F170M3021
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I^2t Rating (660V)
180000A^2/s
Nominal Current (RMS DC)
500 Amp
Tested Breaking Capacity
200kA (78mm Hole Centers) @ 690VAC
Dimensions
45 x 104 x 45mm
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
30W
Termination Style
M10
Unit Weight
350g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fastron Electronics FGC1-F400-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO, Nominal Current = 400 Amps(AC-3) @ 240/400/500/690V
Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
CE, CB Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Electronics Part Number
FGC1-F400-230VAC
Functions
3 Pole Contactor
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
400 Amp Continuous @ 55 Deg C
Main Contacts
3 x NO
Aux Contacts
None
Trip Delay Time
2-10ms
Electrical Life
1,000,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
6,000,000 Ops
Control Voltage
240VAC
Pole Resistance (avg)
0.35m Ohm
Approvals
CE, CB, TUV, LVD
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
TRB-BD21, 1 x NO, 2 Position Toggle Switch BLACK, 3 Amp @ 240VAC, 0.3 Amp @ 24VDC, Plastic/Metal, IEC60947-5-1
Toggle Switches are used to Toggle between 2 or 3 Digital or Analogue Input Signals or to simply turn off control signals. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe and reliable repetitive operation by the user.
Features :
600V Insulation Rating
240VAC @ 3 Amp
22mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRB-BD21-IP40
Functions
1 Pole, 2 Position Toggle Switch
Switch Type
Latching 2 x NO
Nominal Voltage
240VAC @ 50/60Hz, 24VDC
Rated Impulse Voltage
6kV
Nominal Current Range AC
3 Amp @240VAC, 0.3 Amp @ 24VDC
Rated Insulation Voltage
600VAC
Humidity
35-85%
Approvals
CE
Standards
IEC60947-5-1, IP20 (IP40 Installed)
Weight
65g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TRENT TGD-4PL C 63-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 63 Amp, 10kA, 1000VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
4 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-4PL C 50-10kA
Functions
4 Pole MCB - C Curve
Nominal Voltage
1000VDC @ 50/60Hz
Nominal Current Range
50 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TGD-4PL C 50-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 1000VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
4 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-4PL C 50-10kA
Functions
4 Pole MCB - C Curve
Nominal Voltage
1000VDC @ 50/60Hz
Nominal Current Range
50 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TGD-4PL C 40-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 1000VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
4 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-4PL C 40-10kA
Functions
4 Pole MCB - C Curve
Nominal Voltage
1000VDC @ 50/60Hz
Nominal Current Range
40 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TGD-4PL C 32-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 32 Amp, 10kA, 1000VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
4 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-4PL C 32-10kA
Functions
4 Pole MCB - C Curve
Nominal Voltage
1000VDC @ 50/60Hz
Nominal Current Range
32 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TGD-4PL C 25-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 1000VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
4 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-4PL C 25-10kA
Functions
4 Pole MCB - C Curve
Nominal Voltage
1000VDC @ 50/60Hz
Nominal Current Range
25 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TGD-4PL C 20-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 20 Amp, 10kA, 1000VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
4 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-4PL C 20-10kA
Functions
4 Pole MCB - C Curve
Nominal Voltage
1000VDC @ 50/60Hz
Nominal Current Range
20 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TGD-4PL C 16-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 16 Amp, 10kA, 1000VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
4 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB, RCM (Pending)
Specification
TRENT Part Number
TGD-4PL C 16-10kA
Functions
4 Pole MCB - C Curve
Nominal Voltage
1000VDC @ 50/60Hz
Nominal Current Range
16 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TGD-1PL C 40-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 250VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB,RCM (Pending)
Specification
TRENT Part Number
TGD-1PL C 32-10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
250VDC @ 50/60Hz
Nominal Current Range
40 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet
TRENT TGD-1PL C 25-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 250VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Bidirectional
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB,RCM (Pending)
Specification
TRENT Part Number
TGD-1PL C 25-10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
250VDC @ 50/60Hz
Nominal Current Range
25 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Datasheet
Product Datasheet