Trent OEM Pricing Collection

783 products

  • Last stock! Trent NH Blade Style Semiconductor Fuse F170M3014, Blade Style Semiconductor Fuse, 160 Amp, 690VAC, Square Body, Size 1, DIN 43 653,  200kA (78mm Hole Centers) FE-F170M3014 F170M3014, Blade Style Semiconductor Fuse, 160 Amp, 690VAC, Square Body, Size 1, DIN 43 653,  200kA (78mm Hole Centers)-NH Blade Style Semiconductor Fuse-Trent-Fastron Electronics Store

    F170M3021, Blade Style Semiconductor Fuse, 500 Amp, 690VAC, Square Body, Size 1*/80, 200kA (78mm Hole Centres)

    3 pcs in stock

    Trent I^2t (aR) Blade Style Semiconductor Fuse, 500 Amp, 690VAC, Square Body, Size 1*/80, DIN 43 653, 200kA (78mm Hole Centers) F170M3014 Features Square Body, Size 1*/80, DIN 43 653 Wide Range of I^2t Ratings up to 2000 Amp Busbar or Fuse Holder Mounted IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I^2t Short Circuit Protection DC or AC Motor I^2t Protection Battery Fuse Specification Trent Part Number F170M3021 Fuse Type I^2t AR Class Nominal Voltage 690VAC @ 50Hz I^2t Rating (660V) 180000A^2/s Nominal Current (RMS DC) 500 Amp Tested Breaking Capacity 200kA (78mm Hole Centers) @ 690VAC Dimensions 45 x 104 x 45mm Hole Centers 78mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40DegC / 125DegC Watt Loss 30W Termination Style M10 Unit Weight 350g Factory Pack Qty 10   Datasheet Product Datasheet

    3 pcs in stock

    $129.00
    $152.22 inclGST

  • FGC1-F400-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO, Nominal Current = 400 Amps(AC-3) @ 240/400/500/690V FGC1-F400-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO, Nominal Current = 400 Amps(AC-3) @ 240/400/500/690V

    FGC1-F400-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO, Nominal Current = 400 Amps(AC-3) @ 240/400/500/690V

    10 pcs in stock

    Fastron Electronics FGC1-F400-230VAC, AC Contactor, 240VAC Control Voltage, 3 Pole NO, Nominal Current = 400 Amps(AC-3) @ 240/400/500/690V Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp CE, CB Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Fastron Electronics Part Number FGC1-F400-230VAC Functions 3 Pole Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 400 Amp Continuous @ 55 Deg C Main Contacts 3 x NO  Aux Contacts None Trip Delay Time 2-10ms Electrical Life 1,000,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 6,000,000 Ops Control Voltage 240VAC Pole Resistance (avg) 0.35m Ohm Approvals CE, CB, TUV, LVD Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 2kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    10 pcs in stock

    $575.00
    $678.50 inclGST

  • TRB-BD21, 1 x NO, 2 Position Toggle Switch BLACK, 3 Amp @ 240VAC, 0.3 Amp @ 24VDC, Plastic/Metal, IEC60947-5-1 TRB-BD21, 1 x NO, 2 Position Toggle Switch BLACK, 3 Amp @ 240VAC, 0.3 Amp @ 24VDC, Plastic/Metal, IEC60947-5-1

    TRB-BD21, 1 x NO, 2 Position Toggle Switch BLACK, 3 Amp @ 240VAC, 0.3 Amp @ 24VDC, Plastic/Metal, IEC60947-5-1

    200 pcs in stock

    TRB-BD21, 1 x NO, 2 Position Toggle Switch BLACK, 3 Amp @ 240VAC, 0.3 Amp @ 24VDC, Plastic/Metal, IEC60947-5-1 Toggle Switches are used to Toggle between 2 or 3 Digital or Analogue Input Signals or to simply turn off control signals. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe and reliable repetitive operation by the user. Features : 600V Insulation Rating 240VAC @ 3 Amp 22mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TRB-BD21-IP40 Functions 1 Pole, 2 Position Toggle Switch Switch Type Latching 2 x NO Nominal Voltage 240VAC @ 50/60Hz, 24VDC  Rated Impulse Voltage 6kV Nominal Current Range AC 3 Amp @240VAC, 0.3 Amp @ 24VDC Rated Insulation Voltage 600VAC Humidity 35-85% Approvals CE Standards IEC60947-5-1, IP20 (IP40 Installed) Weight 65g Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia   Datasheet Product Datasheet

    200 pcs in stock

    $9.00
    $10.62 inclGST

  • TGD-4PL C 63-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 63 Amp, 10kA, 1000VDC TGD-4PL C 63-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 63 Amp, 10kA, 1000VDC

    TGD-4PL C 63-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 63 Amp, 10kA, 1000VDC

    28 pcs in stock

    TRENT TGD-4PL C 63-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 63 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 50-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 50 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    28 pcs in stock

    $59.50
    $70.21 inclGST

  • TGD-4PL C 50-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 1000VDC TGD-4PL C 50-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 1000VDC

    TGD-4PL C 50-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 1000VDC

    Out of stock

    TRENT TGD-4PL C 50-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 50-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 50 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    Out of stock

    $59.50
    $70.21 inclGST

  • TGD-4PL C 40-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 1000VDC TGD-4PL C 40-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 1000VDC

    TGD-4PL C 40-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 1000VDC

    Out of stock

    TRENT TGD-4PL C 40-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 40-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 40 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    Out of stock

    $59.50
    $70.21 inclGST

  • TGD-4PL C 32-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 32 Amp, 10kA, 1000VDC TGD-4PL C 32-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 32 Amp, 10kA, 1000VDC

    TGD-4PL C 32-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 32 Amp, 10kA, 1000VDC

    Out of stock

    TRENT TGD-4PL C 32-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 32 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 32-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 32 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    Out of stock

    $59.50
    $70.21 inclGST

  • TGD-4PL C 25-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 1000VDC TGD-4PL C 25-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 1000VDC

    TGD-4PL C 25-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 1000VDC

    Out of stock

    TRENT TGD-4PL C 25-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 25-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 25 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    Out of stock

    $59.50
    $70.21 inclGST

  • TGD-4PL C 20-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 20 Amp, 10kA, 1000VDC TGD-4PL C 20-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 20 Amp, 10kA, 1000VDC

    TGD-4PL C 20-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 20 Amp, 10kA, 1000VDC

    Out of stock

    TRENT TGD-4PL C 20-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 20 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 20-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 20 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    Out of stock

    $59.50
    $70.21 inclGST

  • TGD-4PL C 16-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 16 Amp, 10kA, 1000VDC TGD-4PL C 16-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 16 Amp, 10kA, 1000VDC

    TGD-4PL C 16-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 16 Amp, 10kA, 1000VDC

    Out of stock

    TRENT TGD-4PL C 16-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 16 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 16-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 16 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    Out of stock

    $59.50
    $70.21 inclGST

  • TGD-1PL C 40-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 250VDC TGD-1PL C 40-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 250VDC

    TGD-1PL C 40-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 250VDC

    120 pcs in stock

    TRENT TGD-1PL C 40-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 40 Amp, 10kA, 250VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB,RCM (Pending) Specification TRENT Part Number TGD-1PL C 32-10kA Functions 1 Pole MCB - C Curve Nominal Voltage 250VDC @ 50/60Hz Nominal Current Range 40 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    120 pcs in stock

    $19.95
    $23.54 inclGST

  • TGD-1PL C 25-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 250VDC TGD-1PL C 25-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 250VDC

    TGD-1PL C 25-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 250VDC

    120 pcs in stock

    TRENT TGD-1PL C 25-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 250VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Bidirectional  Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB,RCM (Pending) Specification TRENT Part Number TGD-1PL C 25-10kA Functions 1 Pole MCB - C Curve Nominal Voltage 250VDC @ 50/60Hz Nominal Current Range 25 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia   Datasheet Product Datasheet

    120 pcs in stock

    $19.95
    $23.54 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account