FP200160P G2, 2000/5 Amp Split Core CT, Class 0.5 15VA, 83 x 163.5mm Aperture, Dimensions 197 x 245 x 57mm
FP200160P G2, 2000/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP200160P G2 Technology Split Core AC Clip On Current Transformer Ratio 2000/5 Aperture Size 83 x 163.5mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2000Amp x 1.2 Certifications CE Termination Style Screw Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
FP150160P G2, 1500/5 Amp Split Core CT, Class 0.5, 15VA, 83 x 163.5mm Aperture, Dimensions 197 x 245 x 57mm
FP150160P G2, 1500/5 Amp Split Core CT, Class 0.5, 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP150160P G2 Technology Split Core AC Clip On Current Transformer Ratio 1500/5 Aperture Size 83 x 163.5mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Certfications CE Termination Style Screw Unit Weight 3.5kg Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
FP250160P G2, 2500/5 Amp Split Core CT, Class 0.5 15VA, 83 x 163.5mm Aperture, Dimensions 197 x 245 x 57mm
FP250160P G2, 2500/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP250160P G2 Technology Split Core AC Clip On Current Transformer Ratio 2500/5 Aperture Size 83 x 163.5mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2500Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
FP500160P G2, 5000/5 Amp Split Core CT, Class 0.5 15VA, 83 x 163.5mm Aperture, Dimensions 197 x 245 x 57mm
FP500160P G2, 5000/5 Amp Split Core CT, Class 1 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP500160P G2 Technology Split Core AC Clip On Current Transformer Ratio 5000/5 Aperture Size 83 x 163.5mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 4000Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
FP030030P G2, 300/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 25 x 36.5mm Aperture, Dimension 97 x 109 x 34mm
Fastron FP030030P G2, 300/5 Amp Split Core CT, Class 0.5 2.5VA AC Clip On Current Transformer, 25 x 36.5mm Aperture, Dimension 97 x 109 x 34mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP030030P G2 Technology Split Core AC Clip On Current Transformer Ratio 300/5 Aperture Size 25 x 36.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$85.00
$100.30 inclGST -
FP400160P G2, 4000/5 Amp Split Core CT, Class 0.5 15VA, 83 x 163.5mm Aperture, Dimensions 197 x 245 x 57mm
FP400160P G2, 4000/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP400160P G2 Technology Split Core AC Clip On Current Transformer Ratio 4000/5 Aperture Size 83 x 163.5mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 4000Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
FP300160P G2, 3000/5 Amp Split Core CT, Class 0.5 15VA, 83 x 163.5mm Aperture, Dimensions 197 x 245 x 57mm
FP300160P G2, 3000/5 Amp Split Core CT, Class 0.5 15VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP300160P G2 Technology Split Core AC Clip On Current Transformer Ratio 3000/5 Aperture Size 83 x 163.5mm VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2000Amp x 1.2 Certifications CE Termination Style Screw Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$265.00
$312.70 inclGST -
FP010030P/1a G2, 100/1 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 25 x 36.5mm Aperture, Dimension 97 x 109 x 34mm
FP010030P/1A, 100/1 Amp Split Core CT, Class 1, 1VA Clip On AC Current Transformer, 25 x 36.5mm Aperture, Dimension 97 x 109 x 34mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP010030P/1A Technology Split Core AC Clip On Current Transformer Ratio 100/1 Aperture Size 25 x 36.5mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$92.00
$108.56 inclGST -
FP060080P G2, 600/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP060080P G2, 600/5 Amp Split Core CT, Class 1 3VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP060080P G2 Technology Split Core AC Clip On Current Transformer Ratio 600/5 Aperture Size 53 x 83.5mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 600Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP063080P G2, 630/5 Amp Split Core CT, Class 0.5 3VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP063080P G2, 630/5 Amp Split Core CT, Class 1 3VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP063080P G2 Technology Split Core AC Clip On Current Transformer Ratio 630/5 Aperture Size 53 x 83.5mm VA Rating 3VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 630Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP020030P/1a G2, 200/1 Amp Split Core CT, Class 0.5 1.5VA Clip On AC Current Transformer, 25 x 36.5mm Aperture, Dimension 97 x 109 x 34mm
FP020030P/1A, 200/1 Amp Split Core CT, Class 0.5 1.5VA Clip On AC Current Transformer, 25 x 36.5mm Aperture, Dimension 97 x 109 x 34mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP020030P/1A Technology Split Core AC Clip On Current Transformer Ratio 200/1 Aperture Size 25 x 36.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$92.00
$108.56 inclGST -
FP025080P/1a G2, 250/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP025080P/1A, 250/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP025080P/1A Technology Split Core AC Clip On Current Transformer Ratio 250/1 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST