Split Core Current Transformers
-
SCT-F16-160-5A, 160/5 Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-160-5A, 150/5 Amp Measurement Split Core Current Transformer, 16mm Aperture Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-160-5A Technology Split Core AC Current Transformer Ratio 160/5 Amp Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
FP080125P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm
FP080125P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP080125P Technology Split Core AC Clip On Current Transformer Ratio 800/5 Aperture Size 85 x 120mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$137.00
$161.66 inclGST -
Xmer CT Split 105/50SC 100/5 Class 1 1.5VA, 43 x 55mm Aperture
Xmer CT Split 105/50SC 100/5 Class 1 1.5VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 100/5 Class 1 1.5VA Technology Split Core AC Current Transformer Ratio 150/5 Aperture Size 43 x 55mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 150Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
$89.00
$105.02 inclGST -
Xmer CT Split 105/50SC 150/5 Class 1, 1.75VA, 43 x 55mm Aperture
Xmer CT Split 105/50SC 150/5 Class 1, 1.75VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 150/5 Class 1 1.75VA Technology Split Core AC Current Transformer Ratio 150/5 Aperture Size 43 x 55mm VA Rating 1.75VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 150Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
$89.00
$105.02 inclGST -
SCT-F16-60-5A-CL2, 60/5 Amp Measurement, Class 2 Split Core CT's
Fastron Electronics SCT-F16-60-5A-CL2, 60/5 Amp Measurement, Class 2 Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-60-5A-CL2 Technology Split Core AC Current Transformer Ratio 60/5 Amp Aperture Size ø 16 mm VA Rating N/A Accuracy Class Class 2 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 60Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST -
SCT-F16-20-5A-CL5, 5 Amp, 20Amp Measurement, Class 5 Split Core CT's
Fastron Electronics SCT-F16-20-5A-CL5, 5 Amp, 20Amp measurement Split Core CT's CLASS 5 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-20-5A-CL5 Technology Split Core AC Current Transformer Ratio 20/5 Amp Aperture Size ø 16 mm VA Rating N/A Accuracy Class Class 2 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 20Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST -
FP063125P, 630/5 Amp Split Core CT, Class 0.5, 5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm
FP063125P, 630/5 Amp Split Core CT, Class 0.5, 5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP063125P Technology Split Core AC Clip On Current Transformer Ratio 630/5 Aperture Size 85 x 120mm VA Rating 5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 630Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$137.00
$161.66 inclGST -
Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA, 55 x 85mm Aperture
Xmer CT Split Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA, 55 x 85mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 125/50SC 300/5 Class 0.5 2.5VA Technology Split Core AC Current Transformer Ratio 300/5 Aperture Size 55 x 85mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9 Datasheet Product Datasheet
$155.00
$182.90 inclGST -
Xmer CT Split 125/50SC 250/5 Class 0.5, 1VA 55 x 85mm Aperture
Rishabh Xmer CT Split 125/50SC 250/5 Class 0.5, 1VA 55 x 85mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 125/50SC 250/5 Class 0.5 Technology Split Core AC Current Transformer Ratio 250/5 Aperture Size 55 x 85mm VA Rating 1VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9 Datasheet Product Datasheet
$155.00
$182.90 inclGST -
SCT-F24-5, 0.333v, 5Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F24-5, 0.333v, 5Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 0.333v Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F24-5 Technology Split Core AC Current Transformer Ratio 5/0.333v Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 0.333v (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 5Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$49.00
$57.82 inclGST -
SCT-F36-5, 0.333V, 5Amp Measurement, Class 1 Split Core CT's, 35mm Aperture
Fastron Electronics SCT-F36-5, 0.333V, 5Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-5 Technology Split Core AC Current Transformer Ratio 5/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 5Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$84.00
$99.12 inclGST -
FP040030P, 400/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm
Fastron FP040030P, 400/5 Amp Split Core CT, Class 0.5 2.5VA AC Clip On Current Transformer, 20 x 30mm Aperture, Dimension 90 x 40 x 110mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP040030P Technology Split Core AC Clip On Current Transformer Ratio 400/5 Aperture Size 20 x 30mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$85.00
$100.30 inclGST