SCT-F36-150, 0.333V, 150Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-150, 0.333V, 150Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-150 Technology Split Core AC Current Transformer Ratio 150/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-200, 0.333V, 200Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-200, 0.333V, 200Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-200 Technology Split Core AC Current Transformer Ratio 200/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-600-040A, 40mA, 600Amp Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendFastron Electronics SCT-F36-600-040A, 40mA, 600Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-600-040A Technology Split Core AC Current Transformer Ratio 600/40mA Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
Free Aus Post Shipping for $300 Spend$66.50
$78.47 inclGST -
SCT-F36-500-040A, 40mA, 500Amp Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendFastron Electronics SCT-F36-500-040A, 40mA, 500Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-500-040A Technology Split Core AC Current Transformer Ratio 500/40mA Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
Free Aus Post Shipping for $300 Spend$66.50
$78.47 inclGST -
SCT-F36-600, 0.333V, 600Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-600, 0.333V, 600Amp measurement Split Core CT's Class 1, 35mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-600 Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-300, 0.333V, 300Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-300, 0.333V, 300Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-300 Technology Split Core AC Current Transformer Ratio 300/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-400-0.4V, 400mV, 400Amp Measurement, Class 1 Split Core CT's for Power Quality Analysers 1mV/A
Free Aus Post Shipping for $300 SpendFastron Electronics SCT-F36-400-0.4V, 400mV, 400Amp measurement Split Core CT's for Power Quality Analysers 1mV/A Features Quick Release Split Core System Cable Mount 400mV Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-400-0.4V Technology Split Core AC Current Transformer Ratio 400/400mV Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 400mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
Free Aus Post Shipping for $300 Spend$75.00
$88.50 inclGST