Solid Core AC Current Transformers

56 products

  • CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA HIGH BURDEN, Class 1 CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA HIGH BURDEN, Class 1

    CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA HIGH BURDEN, Class 1

    Out of stock

    Rishabh CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA, Class 1 HIGH BURDEN Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 400/5 Class 1 20VA 86/40 (45) Technology AC Current Transformer Ratio 400/5 Aperture Size 36mm or 11x41mm Busbar VA Rating 20VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Moun Operating Temperature Range -30°C / 85°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet

    Out of stock

    $66.70
    $78.71 inclGST

  • CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA HIGH BURDEN, Class 0.5,  Aperture or 11x41mm Busbar CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA HIGH BURDEN, Class 0.5,  Aperture or 11x41mm Busbar

    CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA HIGH BURDEN, Class 0.5, Aperture or 11x41mm Busbar

    15 pcs in stock

    Rishabh CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA, Class 0.5 HIGH BURDEN Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number CT 300/5 Class 0.5 15VA 86/40 (45) Technology AC Current Transformer Ratio 300/5 Aperture Size 36mm or 11x41mm Busbar VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Moun Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet

    15 pcs in stock

    $66.70
    $78.71 inclGST

  • CT 200/5 Class 1 15VA 86/40 (45), Current Transformer 200/5Amp CT 15VA HIGH BURDEN, Class 0.5, 36mm Aperture or 11x41mm Busbar CT 200/5 Class 1 15VA 86/40 (45), Current Transformer 200/5Amp CT 15VA HIGH BURDEN, Class 0.5, 36mm Aperture or 11x41mm Busbar

    CT 200/5 Class 1 15VA 86/40 (45), Current Transformer 200/5Amp CT 15VA HIGH BURDEN, Class 0.5, 36mm Aperture or 11x41mm Busbar

    23 pcs in stock

    Rishabh CT 200/5 Class 1 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA HIGH BURDEN, Class 0.5, 36mm Aperture or 11x41mm Busbar Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number CT 200/5 Class 1 15VA 86/40 (45) Technology AC Current Transformer Ratio 200/5 Aperture Size 36mm or 11x41mm Busbar VA Rating 15VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9   Datasheet Product Datasheet  

    23 pcs in stock

    $66.70
    $78.71 inclGST

  • CT 50/5 Class 1 1.5VA 86/40 (45), Current Transformer 300/5Amp CT 1.5VA WIDE APERTURE, Class 0.5, 36mm Aperture or 11x45mm Busbar CT 50/5 Class 1 1.5VA 86/40 (45), Current Transformer 300/5Amp CT 1.5VA WIDE APERTURE, Class 0.5, 36mm Aperture or 11x45mm Busbar

    CT 50/5 Class 1 1.5VA 86/40 (45), Current Transformer 300/5Amp CT 1.5VA WIDE APERTURE, Class 0.5, 36mm Aperture or 11x45mm Busbar

    Out of stock

    Rishabh CT 50/5 Class 1 1.5VA 86/40 (45), Current Transformer 300/5Amp CT 1.5VA WIDE APERTURE, Class 0.5, 36mm Aperture or 11x45mm Busbar Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number CT 50/5 Class 1 1.5VA 86/40 (45) Technology AC Current Transformer Ratio 50/5 Aperture Size 36mm or 11x41mm Busbar VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 50Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9   Datasheet Product Datasheet  

    Out of stock

    $66.70
    $78.71 inclGST

  • CT 600/5 Class 0.5 15VA 86/60 (45), Current Transformer 600/5Amp CT 15VA, Class 0.5 CT 600/5 Class 0.5 15VA 86/60 (45), Current Transformer 600/5Amp CT 15VA, Class 0.5

    CT 600/5 Class 0.5 15VA 86/60 (45), Current Transformer 600/5Amp CT 15VA, Class 0.5

    Out of stock

    Rishabh CT 600/5 Class 0.5 15VA 86/60 (45), Current Transformer 600/5Amp CT 15VA, Class 0.5 Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number CT 600/5 Class 0.5 15VA 86/60 (45) Technology AC Current Transformer Ratio 600/5 Aperture Size 51mm or 12.5x61mm Busbar VA Rating 15VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Moun Operating Temperature Range -30°C / 85°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9   Datasheet Product Datasheet  

    Out of stock

    $66.70
    $78.71 inclGST

  • Rish Xmer 74-50 (45) 800/5 Class 1, 15VA, ⌀ 51mm or 51 x 12mm Busbar Rish Xmer 74-50 (45) 800/5 Class 1, 15VA, ⌀ 51mm or 51 x 12mm Busbar

    Rish Xmer 74-50 (45) 800/5 Class 1, 15VA, ⌀ 51mm or 51 x 12mm Busbar

    18 pcs in stock

    Rishabh Rish Xmer 74-50 (45) 800/5 Class 1 Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish Xmer 74-50 (45) 800/5 Class 1 Technology AC Current Transformer Ratio 800/5 Aperture Size ⌀ 41mm or 51 x 12mm Busbar VA Rating 15VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Unit Weight 0.6kg Factory Pack Qty 9   Datasheet Product Datasheet  

    18 pcs in stock

    $71.40
    $84.25 inclGST

  • Rish Xmer 86-60 (45) 1000/5 Class 1, 30VA ⌀ 51mm or 61 x 12mm Busbar Rish Xmer 86-60 (45) 1000/5 Class 1, 30VA ⌀ 51mm or 61 x 12mm Busbar

    Rish Xmer 86-60 (45) 1000/5 Class 1, 30VA ⌀ 51mm or 61 x 12mm Busbar

    27 pcs in stock

    Rishabh Rish Xmer 86-60 (45) 1000/5 Class 1 30VA Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 86-60 (45) 1000/5 Class 1 Technology AC Current Transformer Ratio 1000/5 Aperture Size ⌀ 51mm or 61 x 12mm Busbar VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1000Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9 Datasheet Product Datasheet

    27 pcs in stock

    $81.00
    $95.58 inclGST

  • Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA ⌀ 51mm or 61 x 12mm Busbar Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA ⌀ 51mm or 61 x 12mm Busbar

    Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA ⌀ 51mm or 61 x 12mm Busbar

    Out of stock

    Rishabh Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA ⌀ 51mm or 61 x 12mm Busbar, Currentr Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish Xmer 86-40 (45) 50/5 Class 1 1.5VA Technology AC Current Transformer Ratio 50/5 Aperture Size ⌀ 51mm or 61 x 12mm Busbar VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 50Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9   Datasheet Product Datasheet

    Out of stock

    $81.00
    $95.58 inclGST

  • Rish Xmer 86-40 (45) 200/5 Class 1 15VA ⌀ 51mm or 61 x 12mm Busbar Rish Xmer 86-40 (45) 200/5 Class 1 15VA ⌀ 51mm or 61 x 12mm Busbar

    Rish Xmer 86-40 (45) 200/5 Class 1 15VA ⌀ 51mm or 61 x 12mm Busbar

    Out of stock

    Rishabh Rish Xmer 86-40 (45) 200/5 Class 1 15VA ⌀ 51mm or 61 x 12mm Busbar Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish Xmer 86-40 (45) 200/5 Class 1 15VA Technology AC Current Transformer Ratio 200/5 Aperture Size ⌀ 51mm or 61 x 12mm Busbar VA Rating 15VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9   Datasheet Product Datasheet

    Out of stock

    $81.00
    $95.58 inclGST

  • Rish Xmer 86-50 (45) 1200/5 Class 1, 30VA ⌀ 46mm or 51 x 12mm Busbar Rish Xmer 86-50 (45) 1200/5 Class 1, 30VA ⌀ 46mm or 51 x 12mm Busbar

    Rish Xmer 86-50 (45) 1200/5 Class 1, 30VA ⌀ 46mm or 51 x 12mm Busbar

    15 pcs in stock

    Rishabh Rish Xmer 86-50 (45) 1200/5 Class 1 30VA Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 86-50 (45) 1200/5 Class 1 Technology AC Current Transformer Ratio 1200/5 Aperture Size ⌀ 46mm or 51 x 12mm Busbar VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1200Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9 Datasheet Product Datasheet

    15 pcs in stock

    $89.20
    $105.26 inclGST

  • Rish Xmer 86-60 (45) 1200/5 Class 1, 30VA ⌀ 51mm or 61 x 12mm Busbar Rish Xmer 86-60 (45) 1200/5 Class 1, 30VA ⌀ 51mm or 61 x 12mm Busbar

    Rish Xmer 86-60 (45) 1200/5 Class 1, 30VA ⌀ 51mm or 61 x 12mm Busbar

    Out of stock

    Rishabh Rish Xmer 86-60 (45) 1200/5 Class 1 30VA Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish Xmer 86-60 (45) 1200/5 Class 1 Technology AC Current Transformer Ratio 1200/5 Aperture Size ⌀ 46mm or 61 x 12mm Busbar VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1200Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9   Datasheet Product Datasheet

    Out of stock

    $89.20
    $105.26 inclGST

  • Rish Xmer 86-60 (45) 1250/5 Class 1 30VA, ⌀ 51mm or 61 x 12mm Busbar Rish Xmer 86-60 (45) 1250/5 Class 1 30VA, ⌀ 51mm or 61 x 12mm Busbar

    Rish Xmer 86-60 (45) 1250/5 Class 1 30VA, ⌀ 51mm or 61 x 12mm Busbar

    Out of stock

    Rishabh Rish Xmer 86-60 (45) 1250/5 Class 1 30VA, ⌀ 51mm or 61 x 12mm Busbar Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish Xmer 86-60 (45) 1250/5 Class 1 30VA Technology AC Current Transformer Ratio 1250/5 Aperture Size ⌀ 46mm or 61 x 12mm Busbar VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1250Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9   Datasheet Product Datasheet

    Out of stock

    $89.20
    $105.26 inclGST

Login

Forgot your password?

Don't have an account yet?