Timonta 5500-2001 (FPP2-25-1/A), 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter for PCB Mounting
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Specification
Schurter Part Number
5500-2001
Rated Voltage
250V
Rated Current
1A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Standard Attenuation
Leakage Current
0.25mA
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
Solder Pin
Weight
27g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter FMBD-B92D-8012, 2 Stage EMC (RFI) Line Filter for 3-phase 4 wire systems, 80 Amp, 520VAC
Features
3 phase 4 wire line filter with standard attenuation
Available as high voltage filter (up to 520 VAC)
Applications
Voltage rating 520 VAC for world wide acceptance
Protection against interference voltage from the mains
For industrial applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Schurter Part Number
FMBD-B92D-8012
Rated Voltage
520V
Rated Current
80A
Filter Stages
2 Stage (3 Phase)
Operating Temperature
-25°C to 100°C
Filter Type
Excellent Attenuation
Leakage Current
12.7mA
Mounting
Panel Mount
Material
Metal
Termination Style
Screw
Weight
2.8kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter FMBD-B92E-J212, 2 Stage EMC (RFI) Line Filter for 3-phase 4 wire systems, 120 Amp, 520VAC
Features
3 phase 4 wire line filter with standard attenuation
Available as high voltage filter (up to 520 VAC)
Applications
Voltage rating 520 VAC for world wide acceptance
Protection against interference voltage from the mains
For industrial applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Schurter Part Number
FMBD-B92E-J212
Rated Voltage
520V
Rated Current
120A
Filter Stages
2 Stage (3 Phase)
Operating Temperature
-25°C to 100°C
Filter Type
Excellent Attenuation
Leakage Current
13.6mA
Mounting
Panel Mount
Material
Metal
Termination Style
Screw
Weight
6.8kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter FMBD-B92B-3612, 2 Stage EMC (RFI) Line Filter for 3-phase 4 wire systems, 36 Amp, 520VAC
Features
3 phase 4 wire line filter with standard attenuation
Available as high voltage filter (up to 520 VAC)
Applications
Voltage rating 520 VAC for world wide acceptance
Protection against interference voltage from the mains
For industrial applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Schurter Part Number
FMBD-B92B-3612
Rated Voltage
520V
Rated Current
36A
Filter Stages
2 Stage (3 Phase)
Operating Temperature
-25°C to 100°C
Filter Type
Excellent Attenuation
Leakage Current
12.7mA
Mounting
Panel Mount
Material
Metal
Termination Style
Screw
Weight
1.9kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter FMBD-B92B-2512, 2 Stage EMC (RFI) Line Filter for 3-phase 4 wire systems, 25 Amp, 520VAC
Features
3 phase 4 wire line filter with standard attenuation
Available as high voltage filter (up to 520 VAC)
Applications
Voltage rating 520 VAC for world wide acceptance
Protection against interference voltage from the mains
For industrial applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Schurter Part Number
FMBD-B92B-2512
Rated Voltage
520V
Rated Current
25A
Filter Stages
2 Stage (3 Phase)
Operating Temperature
-25°C to 100°C
Filter Type
Excellent Attenuation
Leakage Current
12.7mA
Mounting
Panel Mount
Material
Metal
Termination Style
Screw
Weight
1.8kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter FMBD-B92A-1612, 2 Stage EMC (RFI) Line Filter for 3-phase 4 wire systems, 16 Amp, 520VAC
Features
3 phase 4 wire line filter with standard attenuation
Available as high voltage filter (up to 520 VAC)
Applications
Voltage rating 520 VAC for world wide acceptance
Protection against interference voltage from the mains
For industrial applications
Suitable for use in equipment according to IEC/UL 60950
Medical Version Available
Specification
Schurter Part Number
FMBD-B92A-1612
Rated Voltage
520V
Rated Current
16A
Filter Stages
2 Stage (3 Phase)
Operating Temperature
-25°C to 100°C
Filter Type
Excellent Attenuation
Leakage Current
11.1mA
Mounting
Panel Mount
Material
Metal
Termination Style
Screw
Weight
1.2kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2070 (FMBB-0131-1610), 2 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for high current applications
Protection against interference voltage from the mains
Possible interferences generated in the equipment are strongly attenuated
Especially designed for industrial applications such as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Standard Version
Specification
Schurter Part Number
5500-2070
Rated Voltage
250V
Rated Current
16A
Filter Stages
2 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Broad Band Attenuation - Industrial Version
Leakage Current
3.5mA
Mounting
Panel Mount - Case 31-2
Material
Metal
Termination Style
Screw
Weight
2.4kg
Factory Pack Qty
4
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2219, 2 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2219
Rated Voltage
250V
Rated Current
20A
Filter Stages
2 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.5mA
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
840g
Factory Pack Qty
4
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2063, 2 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2063
Rated Voltage
250V
Rated Current
10A
Filter Stages
2 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
2.5mA
Mounting
Panel Mount - Case 48
Material
Metal
Termination Style
Screw
Weight
275g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Â
Datasheet
Product Datasheet
Â
Schurter 5500-2062, 2 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2062
Rated Voltage
250V
Rated Current
10A
Filter Stages
2 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.25mA
Mounting
Panel Mount - Case 48
Material
Metal
Termination Style
Screw
Weight
275g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2056, 2 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2056
Rated Voltage
250V
Rated Current
10A
Filter Stages
2 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
1.4mA
Mounting
Panel Mount - Case 48
Material
Metal
Termination Style
Screw
Weight
275g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2053, 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2053
Rated Voltage
250V
Rated Current
3A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.25mA
Mounting
Panel Mount - Case 48
Material
Metal
Termination Style
Screw
Weight
275g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet