Rocker & Pushbutton Switches with Thermal Overload Protection
-
4430.4007 TA45-ABTWM200C0-AZM01, 2 Pole Rocker Switch, Non Latched, 20 AMP, 240VAC, 1 Pole Thermal Overload Protection, Faston Connection, No Illumination, Collar with Cover Narrow IP54
Schurter, 4430.4007 TA45-ABTWM200C0-AZM01, 2 Pole Rocker Switch, Non Latched, 20 AMP, 240VAC, 1 Pole Thermal Overload Protection, Faston Connection, No Illumination, Collar with Cover Narrow IP54 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 44430.4007 (TA45-ABTWM200C0-AZM01) Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 20 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Illumination Transparent Green Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$59.00
$69.62 inclGST -
4430.0582, IP54 Cover for TA45 Pole Rocker Switch #AZM10
Schurter, 4430.0582, IP54 Cover for TA45 Pole Rocker Switch #AZM10 Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description IP54 Cover for TA45 Series Rocker Switches Specification Schurter Part Number 4430.0582 (AZM10) Functions IP54 Cover Material PVC,PA6 Datasheet Product Datasheet
$3.75
$4.43 inclGST -
4430.0558 TA45-A126F160C0, 2 Pole Rocker Switch, 16 AMP, 240VAC, 1 Pole Thermal Overload Protection, Quick Connection, Embossed Orange Transparent Illumination
Schurter, 4430.1693 TA45-A126F160E3, 2 Pole Rocker Switch, 16 AMP, 240VAC, 1 Pole Thermal Overload Protection, 230VAC Undervoltage Release, Quick Connection, Embossed Orange Transparent Illumination Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4430.0558 (TA45-A126F160C0) Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC (230VAC Undervoltage Release) Nominal Current Range 16 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Illumination Transparent Orange Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$31.00
$36.58 inclGST -
4435.0395 TA35-CBDBF100C0-000, 2 Pole Rocker Switch, 10 AMP, 240VAC, 60VDC, Faston Connection, Black with I/O Embossed
Schurter 4435.0395 TA35-CBDBF100C0-000, 2 Pole Rocker Switch, 10 AMP, 240VAC, 60VDC, Faston Connection, Black with I/O Embossed Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 2 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4435.0395 TA35-CBDBF100C0-000 Functions 2 Pole Rocker Switch, with 2 Bimetal Thermal Overload Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 60VDC Nominal Current Range 10 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Insulation Resistance 500VDC Illumination None Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$45.00
$53.10 inclGST -
4430.1693 TA45-A126F160E3, 2 Pole Rocker Switch, 16 AMP, 240VAC, 1 Pole Thermal Overload Protection, 230VAC Undervoltage Release, Quick Connection, Embossed Orange Transparent Illumination
Schurter, 4430.1693 TA45-A126F160E3, 2 Pole Rocker Switch, 16 AMP, 240VAC, 1 Pole Thermal Overload Protection, 230VAC Undervoltage Release, Quick Connection, Embossed Orange Transparent Illumination Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4430.1693 (TA45-A126F160E3) Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC (230VAC Undervoltage Release) Nominal Current Range 16 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Illumination Transparent Green Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$75.00
$88.50 inclGST -
4430.2050 TA45-A624F160C0, 2 Pole Rocker Switch, Non Latched, 16 AMP, 240VAC, 1 Pole Thermal Overload Protection, Screw Connection, Embossed Green Transparent Illumination
Schurter, 4430.2050 TA45-A624F160C0, 2 Pole Thermal Circuit Breaker Rocker Switch for Electrical Appliance, 240VAC/28VDC, 16 Amp Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4430.2050 TA45-A624F160C0 Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 16 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Illumination Transparent Green Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$50.21
$59.25 inclGST -
4430.0031 ABTWF150C0, 2 Pole Rocker Switch, Non Latched, 15 AMP, 240VAC, 1 Pole Thermal Overload Protection, Screw Connection, Embossed White
Schurter, 4430.0031 ABTWF150C0, 2 Pole Rocker Switch, Non Latched, 15 AMP, 240VAC, 1 Pole Thermal Overload Protection, Screw Connection, Embossed White Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4430.0031 ABTWF150C0 Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 15 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Illumination Transparent Green Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$35.00
$41.30 inclGST -
4430.0024 ABTWF120C0, 2 Pole Rocker Switch, Non Latched, 12 AMP, 240VAC, 1 Pole Thermal Overload Protection, Screw Connection, Embossed White
Schurter, 4430.0024 ABTWF120C0, 2 Pole Rocker Switch, Non Latched, 12 AMP, 240VAC, 1 Pole Thermal Overload Protection, Screw Connection, Embossed White Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4430.2050 TA45-A624F160C0 Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 16 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Illumination Transparent Green Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$35.00
$41.30 inclGST -
4430.2985 TA45-A126F180C0, 2 Pole Rocker Switch, 18 AMP, 240VAC, 1 Pole Thermal Overload Protection, Quick Connection, Embossed Orange Transparent Illumination
Schurter, 4430.2985 TA45-A126F180C0, 2 Pole Rocker Switch, 18 AMP, 240VAC, 1 Pole Thermal Overload Protection, Quick Connection, Embossed Orange Transparent Illumination Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4430.2985 (TA45-A126F180C0) Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC (230VAC Undervoltage Release) Nominal Current Range 18 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Insulation Resistance 500VDC Illumination Transparent Orange Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$65.00
$76.70 inclGST -
4435.0077 TA35-CBTBL150C0, 2 Pole Rocker Switch, Non Latched, 15 AMP, 240VAC, 60VDC with 1 Pole Thermal Overload Protection, Faston Connection, Black with White I/O
Schurter 4435.0077 TA35-CBTBL150C0, 2 Pole Rocker Switch, Non Latched, 15 AMP, 240VAC, 60VDC with 1 Pole Thermal Overload Protection, Faston Connection, Black with White I/O Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4435.0077 TA35-CBTBL150C0 Functions 2 Pole Rocker Switch with 1 Bimetal Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 60VDC Nominal Current Range 16 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Insulation Resistance 500VDC Illumination None Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$40.00
$47.20 inclGST -
4435.0173 TA35-CFTBF050C0, 1 Pole Rocker Switch, Non Latched, 5 AMP, 240VAC, 60VDC, Thermal Overload Protection, Faston Connection, Black with White I/O Embossed
Schurter 4435.0173 TA35-CFTBF050C0, 1 Pole Rocker Switch, Non Latched, 5 AMP, 240VAC, 60VDC, Thermal Overload Protection, Faston Connection, Black with White I/O Embossed Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch 1-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4435.0173 TA35-CFTBF050C0 Functions 1 Pole Rocker Switch, with 1 Bimetal Thermal Overload Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 60VDC Nominal Current Range 5 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Insulation Resistance 500VDC Illumination None Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 10g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$23.25
$27.44 inclGST -
4430.0035 ABTWF200C0, 2 Pole Rocker Switch, Non Latched, 20 AMP, 240VAC, 1 Pole Thermal Overload Protection, Screw Connection, Embossed White
Schurter, 4430.0035 ABTWF200C0, 2 Pole Rocker Switch, Non Latched, 20 AMP, 240VAC, 1 Pole Thermal Overload Protection, Screw Connection, Embossed White Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction Description Rocker Switch Thermal circuit breaker 2-pole - Power tools Manual ON/OFF type Quick connect terminals 6.3 x 0.8 mm Features : < 3mS Trip Delay Time 1 Pole Disconnect 1kA Short Circuit Rating Suitable for 500VDC Isolation Applications: Power Tools Household Equipment Power Supplies and Chargers Industrial Appliances Standards : IEC 60934 2 x Ir: 5000 Cycles 500VDC Insulation Resistance 1.5kV (50Hz) Dielectric Strength Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips Specification Schurter Part Number 4430.0035 ABTWF200C0 Functions 2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker Nominal Voltage 240VAC @ 50Hz or 28VDC Nominal Current Range 20 Amp RMS Trip Delay Time < 3ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Illumination Transparent Green Insulation Resistance 500VDC Dielectric Strength 1.5kV (50Hz) Short Circuit Current 1kA Approvals UL, CSA Standards IEC 6094 Weight 100g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
$35.00
$41.30 inclGST