Crydom D1D20, Solid State Relay, DC 3-32VDC control, 20A, 100VDC Load
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D1D20
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
20 Amp DC
Surge Capability (10ms)
42 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
0 - 100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See alternative D1D40 D1D40K with raised Gen 3 terminals or D1D80 for higher current alternative
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Schurter 0034.3119, FST 5x20mm Time Lag Fuse 1.6Amp, 250VAC, 10 x In, IEC 60127-2
Features
Meets UL and IEC standards
UL Recognized for 250VAC
High breaking capacity of 10 x In @ 250VAC
Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation
Applications
Electrical Appliances
Power Supply Adapters
Switch Mode Power Supplies
Avionics
In-line protection
Specification
Schurter Part Number
0034.3119
Fuse Type
I²t Time lag
Nominal Voltage
250VAC
I²t Rating (Pre-Arcing)
3.3 A²/s
Nominal Current (AC rms)
1 Amp
Tested Breaking Capacity
10 x In @250VAC
Dimensions
5 x 20mm
Fuse Holder
0031-2203 Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-55°C / 125°C
Watt Loss
0.2W
Unit Weight
1.2g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
0031-2203 Shock Proof Fuse Holders
Schurter 0034.3121, FST Glass 5x20mm Time Lag Fuse 2.5Amp, 250VAC, 10 x In, IEC 60127-2
Features
Meets UL and IEC standards
UL Recognized for 250VAC
High breaking capacity of 10 x In @ 250VAC
Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation
Applications
Electrical Appliances
POwer Supply Adaptors
Switch Mode Power Supplies
Avionics
In-line protection
Specification
Schurter Part Number
0034.3121
Fuse Type
I²t Time lag
Nominal Voltage
250VAC
I²t Rating (Pre-Arcing)
21.9 A²/s
Nominal Current (AC rms)
2.5 Amp
Tested Breaking Capacity
10 x In @250VAC
Dimensions
5 x 20mm
Fuse Holder
0031-2203 Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-55°C / 125°C
Watt Loss
0.4W
Unit Weight
1.2g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
0031-2203 Shock Proof Fuse Holders
Crydom EZ240D18R, Solid State Relay, 4-15VDC control, 18A, 24-280VAC Load, Random Crossing, Faston
Features
Ratings from 5A to 18 Amp @ 600 VAC
Faston terminals for easy installation
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
EZ240D18R
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-15VDC
Load Current
18 Amp (rms)
Surge Capability
200 Amp (peak)
Special Feature
Faston terminals
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Faston
Unit Weight
43g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron F157FT 2PL 8A 24VDC + F157F-2Z-C3, Relay, DPDT 8 Amp Form C, 250VAC/30VDC Load, 24VDC Coil
Features
2 x SPDT 8 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Slim package
Compatible with Omron G2R-1-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Suits F157F-1Z-C3 socket
Specification
Fastron Part Number
F157FT 2PL 8A 24VDC + F157F-1Z-C3
Switching Type
DPDT 30VDC/250VAC C/OÂ Form C
Approvals
UL, CE
Coil Voltage
230VAC
Load Current
2 x 8 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
60g
Factory Pack Qty
20
Â
Datasheet
Relay Datasheet
Socket Replacement
F157F-1Z-C3
Relay Replacement
F157FT1PL 12A 24VDC
RTR Energia REG12DPR1400000 PR-14D.12 8/10/12 Step Automatic Reactive Power Controller, 3 Phase
Isolated Switching of Power Factor Correction Contactors
Cos Ï• Setting 0.80 to 0.95 CAP
Single CT Sensing
1A/5A Programmable Primary and secondary CT Ratio
Backlit LCD Display
Various Program Combinations
IP40
Up to 12 steps
Measurement System - Automatic/Manual
230VAC Aux Supply
Overvoltage and Under/Overcompensation management
Overtemperature alarm
Â
Specification
RTR Energia Part Number
PR-14D.12
Function
Reactive Power Correction
Nominal Voltage (Un)
90-550V L to L, 11-300V L-N
Supply Voltage
90-550V L to L, 15VA (max) 45-65Hz
Relay Rating
250VAC/6Amp NO
Switch Delay Time
1s - 999s User Adjustable
Fan Alarm
1 x 250VAC/6Amp NO
Temperature Alarm
1 x 250VAC/6Amp NO
Re-connection Delay Time
1s - 999s User Adjustable
Desired Power Factor
0.85 IND - 0.95 CAP
Number of Output Relays
14 (12 steps, fan and temperature alarm)
Smallest Capacitor Current
50mA
CT Input Range
0.05 - 5.5 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 Target PFC (Optional)
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP40 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
0...60 °C
Â
Datasheet
Product Datasheet/User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Gigavac GV242CAB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 24VDC Coil
Features
Hermetically Sealed
Side Mounting
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV242CAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
N/A
Mounting Style
Panel Mount (M5), Side Mounted
Load Voltage Range
100 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet