Recommended products

4102 products

  • D2475T-10, SSR Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Random Crossing, Gen 3 Photo Transistor Isolation

    D2475T-10, SSR Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Random Crossing, Gen 3 Photo Transistor Isolation

    191 pcs in stock

    Crydom D2475T-10, SSR Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Random Crossing, Gen 3 Photo Transistor Isolation Features • Ratings from 25A to 125 Amp @ 24-280 VAC • SCR output for heavy industrial loads • Zero voltage or instantaneous turn-on outputs • UL/CSA/VDE Approved, CE Compliant to EN60950-1 • Improved SEMS screw and washer • Redesigned housing with anti-rotation barriers • AC & DC control types • Direct bond copper substrate • EMC compliant to Level 3 • Direct power lead frame • Epoxy free design Spec Crydom Part Number D2475T-10 Switching Type Random Crossing ROHS Yes (Details) Control Voltage 3-32VDC Load Current 40 Amp (rms) Surge Capability 954 Amp (peak) Special Feature Gen 3 Photo Isolator Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Please note Changes from Gen 3 to Gen 4 (current) package design here Alternatives See HD48125-10 or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies

    191 pcs in stock

    $138.52
    $163.45 inclGST

  • BKA400AA10, Schottky Diode Rectifier Module, 400 Amp, 100V, Isolated TO-244 Package

    BKA400AA10, Schottky Diode Rectifier Module, 400 Amp, 100V, Isolated TO-244 Package

    12 pcs in stock

    Sanrex BKA400AA10, Schottky Diode Rectifier Module, 400 Amp, 100V, Isolated TO-244 Package Features Pressure Contact Technology Electrically insulated base plate Very low forward voltage drop Very low leakage current Planar passivated chips International standard package 2500V Isolation 20mm Base Width Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Filed Supply for DC Motors DC supply for PWM inverter Specification Sanrex Part Number BKA400AA10 Vrrm 100V Diode Configuration Schottky Diode Rectifier - Common Cathode IF(av) @ 125 Deg C (50% Duty) 400 Amp per device, 200 Amp per leg Package Size W:20mm L:93mm D:16.5mm Itsm 3.62 kA VF(to) 0.78 -> 0.93V Tj(max) 150°C rF Not Published Terminals 1/4"-20UNC Hole Centres 80mm (M6) Gate Terminals N/A R th(j-c) R th(c-h) 0.20°C/W Weight 68g Mounting Torque 40 Nm (40 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Sanrex Headquarters Japan Datasheet Product datasheet  

    12 pcs in stock

    $128.00
    $151.04 inclGST

  • DWF100A40 Three Phase Half Wave Diode Rectifier Bridge, Common Cathode 100 Amp @ Tc = 122 Deg C

    DWF100A40 Three Phase Half Wave Diode Rectifier Bridge, Common Cathode 100 Amp @ Tc = 122 Deg C

    6 pcs in stock

    IXYS DWF100A40 Three Phase Half Wave Diode Rectifier Bridge, Common Cathode 100 Amp @ Tc = 122 Deg C Features Package with DCB ceramic base plate Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL registered, E 148688 Applications Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Sanrex Part Number DWF100A40 AC Line voltage 400VAC Device Configuration Three Phase Half Wave Diode Rectifier Bridge Common Cathode DC Output @ Tc = 122 Deg C 100 Amp Package Size W:25mm L:92mm D:31mm Itsm 2000 A Tj(max) 150°C Terminals M5 (1.5Nm) Hole Centres 20mm (M4) Gate Terminals N/A R th(j-c) 0.25°C/W Weight 170g Isolation 3kV Factory Pack Qty 10 Certification UL Listed Sanrex Headquarters Japan   Datasheet Product Datasheet Alternatives See Powersem PSYD120/16 for for alternative  

    6 pcs in stock

    $90.00
    $106.20 inclGST

  • Crydom - Sensata SSR DC Load DC60S3, Solid State Relay, DC 3-32VDC control, 3A, 60VDC Load FE-DC60S3

    DC60S5-B, NORMALLY CLOSED Solid State Relay, DC 3-32VDC control, 5A, 60VDC Load

    18 pcs in stock

    Crydom DC60S5-B, NORMALLY CLOSED Solid State Relay, DC 3-32VDC control, 5A, 60VDC Load Features Ratings from 3A to 40 Amp @ 3-60VDC Transistor output UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number DC60S5-B Switching Type DC Load ROHS Yes (Details) Control Voltage 3-32VDC Load Current 5 Amp DC Surge Capability (10ms) 10 Amp DC Special Feature Normally Closed Mounting Style Panel Mount Load Voltage Range 3 - 60VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent See D1D40K with raised terminals (Gen 3) for alternative or DC60S7, D1D20, D1D40, D1D80 for higher current alternatives App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies

    18 pcs in stock

    $75.73
    $89.36 inclGST

  • KS32/12-48D3N, Slimline Relay, 12VDC Coil, 48VDC 3 Amp Load

    KS32/12-48D3N, Slimline Relay, 12VDC Coil, 48VDC 3 Amp Load

    198 pcs in stock

    Keysolu KS32/12-48D3N, Slimline Relay, 12VDC Coil, 48VDC 3 Amp Load Features Output 3.5Amp @ 24VDC 15-30VDC Control input DIN Rail Mount Ultra slim package CE Compliant to IEC 60664 IP67 Specification Crydom Part Number KS32/12-48D3N Switching Type 48VDC 3 Amp Load SSR Approvals UL, CE ROHS Yes (Details) Control Voltage 12VDC Load Current 3 Amp (rms) Special Feature LED Status Indicator Mounting Style Socket Mount (F41F-1Z-C2-5 12-14VAC/DC) Load Voltage Range 48VDC Load EMC Compliant Level 3 Termination Style PCB or Socket Mount Unit Weight 6g Factory Pack Qty 20   Datasheet Relay Datasheet F41F-1Z-C2-5 12-14VAC/DC Socket

    198 pcs in stock

    $25.00
    $29.50 inclGST

  • IL-20-0001 (IL5-20-2), Pulse Transformer IL-20-0001, 1:1:1, Iz = 250mA, Ub(V) = 380V

    IL-20-0001 (IL5-20-2), Pulse Transformer IL-20-0001, 1:1:1, Iz = 250mA, Ub(V) = 380V

    410 pcs in stock

    Schurter IL-20-0001 (IL5-20-2), Pulse Transformer Features High insulation rating (>2.2 kVAC) between the primary and the secondary windings Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics Cost optimized design The defined partial discharge voltage guarantees an effectively unlimited serviceable live Applications   Galvanic separation of drive and power-circuit Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's DC/DC converters Line coupling transformers in high speed data transmission   Specification Schurter Part Number IL-20-0001 (IL5-20-2) Rated Voltage 380V Rated Current (Iz) 250mA Inductance 3mH Transformer Ratio 1:1:1 Rated Power (Pm) 1.1W Resistance (RL) 2 x 40Ω Rise Time (Tr) 1.5uS Operating Temperature -25°C to 125°C Mounting PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 14g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 3.5kV VDE/UL/CSA/ROHS Yes   Datasheet Product Datasheet Application Notes  

    410 pcs in stock

    $8.63
    $10.18 inclGST

  • HSNBV-D05,Automotive Open Loop Current Sensor for up to 48VDC Battery, +/-50 Amp and +/-400Amp Dual Outputs, Battery Drive, Vref = 2.5V output

    HSNBV-D05,Automotive Open Loop Current Sensor for up to 48VDC Battery, +/-50 Amp and +/-400Amp Dual Outputs, Battery Drive, Vref = 2.5V output

    383 pcs in stock

    Automotive Open Loop Current Sensor for up to 48VDC Battery, +/-50 Amp and +/-400Amp Dual Outputs, Battery Drive, Vref = 2.5V output Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range, +/-50 Amp and +/-400Amp Dual Outputs Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number HSNBV-D05 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-50 Amp Load Current Channel 2 (RMS) +/-400 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Mounting Style Panel Mount/Cable Mount Termination Style Fuse Mounting Style Unit Weight 25g Factory Pack Qty 6 Datasheet Product Datasheet

    383 pcs in stock

    $59.00
    $69.62 inclGST

  • DHR 600 C420, Hall Effect Current Sensor, 600Amp RMS , 4-20mA output, 32mm aperture

    DHR 600 C420, Hall Effect Current Sensor, 600Amp RMS , 4-20mA output, 32mm aperture

    52 pcs in stock

    LEM DHR 600 C420, Hall Effect Current Sensor, 600Amp RMS , 4-20mA output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ?32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 600 C420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 600 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6   Datasheet Product Datasheet

    52 pcs in stock

    $394.00
    $464.92 inclGST

  • MCT-0016-050, 50 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)

    MCT-0016-050, 50 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)

    7 pcs in stock

    Magnelab MCT-0016-050, 50 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple) Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 20-30VDC Loop Powered Isolated plastic case recognised according to UL94-V0 UL, CE, ROHS Approved Advantages Large aperture for cable up to ⌀ 24mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification Magnelab Part Number MCT-0016-050 Technology AC Current Transducer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 50 Amp Output 4-20mA (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy +/-2% Ripple on output Termination Style Screw Aperture 16mm Approvals UL, CE, ROHS Unit Weight 170g Factory Pack Qty 6 Datasheet Product Datasheet

    7 pcs in stock

    $171.00
    $201.78 inclGST

  • Last stock! AM5H-A-D-V5-A-R4-AN, 96x48mm Digital Voltmeter 0-36VDC with 4-20mA output, 100-240VAC/DC supply, 4 x Relay Alarms, 5 Digit

    AM5H-A-D-V5-A-R4-AN, 96x48mm Digital Voltmeter 0-36VDC with 4-20mA output, 100-240VAC/DC supply, 4 x Relay Alarms, 5 Digit

    1 pcs in stock

    Fastron Electronics AM5H-A-D-V5-A-R4-AN, 96x48mm Digital Voltmeter 0-36VDC with 4-20mA output, 100-240VAC/DC supply, 4 x Relay Alarms, Digital Panel Meter & Transmitter, 5 Digit Adjustable Zero and Span Setting Adjustable Display Scaling Large 5 Digit 20.3mm (8 Inch) LED Display 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 96 x 48mm Panel Space 90mm Depth Specification Fastron Electronics Part Number AM5H-A-D-V5-A-R4-AN Conditioner Output 4-20mA Input 0 - 36VDC Alarms 4 x Hi/Low, 7 Amp @ 277VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Display Type 5 Digit RED LED Termination Style Screw Mounting Style 96 x 48mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1   Datasheet Product Datasheet User Manual Application Notes Panel Meters Blog Articles

    1 pcs in stock

    $345.00
    $407.10 inclGST

  • HTFS 600-P, O/L Hall Effect Current Sensor, 600 Amp, 5VDC Supply, PCB Mount, X = 1%

    HTFS 600-P, O/L Hall Effect Current Sensor, 600 Amp, 5VDC Supply, PCB Mount, X = 1%

    165 pcs in stock

    LEM HTFS 600-P, Open Loop Hall Effect Current Sensor, 600 Amp, 5VDC Supply, PCB Mount, X = 1% Features Bandwidth DC to 240kHz Open loop transducer using Hall effect Compact and versatile Uinique PCB Mounting Insulated plastic case recognized according to UL 94-V0 Advantages Fixed offset Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTFS 600-P Technology Open Loop Hall Effect Aperture ø 22mm ROHS Yes Supply Voltage 5 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/-900 Amp Output 1.65Vref Isolation 2.5 kV Bandwidth DC-240 kHz Mounting Style PCB Mount (fixation with 4 pins 1mm) Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet

    165 pcs in stock

    $46.60
    $54.99 inclGST

  • H12D4840DE, Dual Solid State Relay, Two Pole 15-32VDC Control, 2 x 40A, 48-530VAC Load

    H12D4840DE, Dual Solid State Relay, Two Pole 15-32VDC Control, 2 x 40A, 48-530VAC Load

    30 pcs in stock

    Crydom H12D4840DE, Dual Solid State Relay, Two Pole 15-32VDC Control, 2 x 40A, 48-530VAC Load Features Ratings from 2 x 25A to 2 x 40 Amp @ 48-480VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number H12D4840DE Switching Type Zero Crossing (Dual) ROHS Yes (Details) Control Voltage 15-32VDC Load Current 2 x 40 Amp (rms) Surge Capability 597 Amp (peak) Special Feature Dual SSR, 1200V Transient Withstand Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style faston Unit Weight 89g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent See CC4850W3VH App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies

    30 pcs in stock

    $225.41
    $265.98 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account