Trent NBR-20 001 13-160A-500V-120kA-NH00, Semiconductor Type gG/gL Fuse, 160 Amp, 120kA, 500VAC, NH00, 78 x 46 x 29.5mm
Square Body Size NH00
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500Â V Voltage Rating
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-20 001 13-160A-500V-120kA-NH00
Fuse Type
I²t gG/gL Class
Nominal Voltage
500VAC @ 50Hz
Nominal Current (RMS + DC)
160 Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
78 x 46 x 29.5mm
Hole Centers
N/A Blade Style
Mounting
Fuse Holder Mounting
Operating Temperature Range
-40°C / 125°C
Termination
Blade
Unit Weight
900g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Crouzet 87622061, Totalizer/Counter with orange Backlit Display CTR24 4-30VDC, Lithium Battery Powered 8 year battery Life
Counter with two totalizers with Common Input
IP65
4-30VDC, 10-260VAC Aux Supply
6 Digit Display (8mm)
7.5kHz Maximum Frequency
50. x 24mm Cutout
Scaling Factor
Rest On Panel or External Inhibit
Suitable to replace 87622062 & 87610040
Datasheet
Product Datasheet
E62.R17-124C60, 120uF, AC Film Capacitor ø116 x 176mm, M6x12 terminals with Bushing. C6 Design. Optimized For High RMS Currents, Voltage: 2000VDC/1200VAC
Characteristics and utility
120uF 1200VAC/1680VDC
Metalized Polypropylene Film
Connector type - M6 x 12mm Studs
M12 Stud mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
E62.R17-124C60
Technology
Metalized Polypropylene Film Capacitor
Dimensions
ø116 x 176mm
Mounting
M12 Stud
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
1075VAC/1680VDC
Operating Temperature Range
-40 to 85 °C
Capacitance
120uF
Tolerance On Capacitance
+10 / -10%
Lifetime
200,000 Hours @ 85 °C (Statistical Life)
Termination Style
M6 x 12 studs
Unit Weight
2kg
Factory Pack Quantity
21 (MOQ = 105)
Â
Datasheet
Product Datasheet
Gigavac PNC113BDA, Contactor SPST-NC, 50 AMP, 1200VDC, 12VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals
Features
Perfect for Capacitor Discharge or Dump Switch Applications
Hermetically Sealed (Patented) rated to 175 Deg C
High Efficiency Dual DC Coils - 12,24,48VDC options
Ideal for battery powered systems or where low power is needed
Built in Coils suppression for all DC Coils
Small and lightweight
Flexible package for installation
CE Approved
Specification
Gigavac Part Number
PNC113BDA
Main Contact Type
SPST-NC
Auxiliary Contact Type
N/A
Coil Voltage
12VDC
Load Current
50 Amp
Mechanical Life @ 0 Amp
50,000 Operations
Impulse Withstand
6kV rms
Control Input Terminals
M3 Screw
Special Feature
N/A
Mounting Style
Panel Mount (M4)
Load Voltage Range
1500VDC
Standards
CE Approved
Termination Style
M4 Screw
Unit Weight
135g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FC5-L-W-2-G-2 PID Controller, 100-240VAC with 2 Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm, Dual Relay and SSR Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-L-W-2-G-2
Control Output
Relay and SSR (Dual Ouptut)
Input
Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 Alarms
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Â
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Infineon FF75R12RT4 IGBT Dual Module
Features
IGBT for Low Frequency Inverter
Pressure Contact Technology
Electrically insulated base plate
Wide Temperature Range
Medium Switching Speed
4000V Isolation
34mm Base Width
Applications
Frequency Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
Low Frequency Inverter
Drives
Specification
Infineon Part Number
FF75R12RT4
Vces
1200V
Transistor Configuration
Dual IGBT Module (Half Bridge)
Ic(nom) @ 100 Deg C
75 Amp
Package Size
W:34mm L:94mm D:308mm
V(isol)
4.0 kV
Vf @ 25 Deg C
1.7 - 2.15V
Tj(max)
175°C
Td(on) @ 25 Deg C
0.13uS
Td(off) @ 25 Deg C
0.3uS
I(ces) @ 25 Deg C
1mA
Rcc
0.65mOhm
Terminals
M5 Screw
Hole Centres
80mm(M6)
Gate Terminals
Spade (A 2.8 - 0.5mm)
R th(j-c)
0.58°C/W
R th(c-h)
0.125°C/W
Weight
160g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See FF75R12RT4, BSM100GB120DLCK or Contact Us for Possible Replacement for alternative
Eastron Europe SDM72CT-D, DIN Rail Mount kWh Meter, 3 Phase, with Resettable Energy Register, 500VAC L-L, Class 1, 1/5 Amp CT Connect input, w/ 1 x fixed pulse output and RS485 Comms, MID Approved. Built for EV Chargers
Â
Features
Â
3 x 1/5 Amp CT Input
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages. Note only kWH is shown on display
1Â x Pulse Outputs (fixed)
Â
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM72CT-D
Functions
Three Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
415V L-L 230V L-N, 5000 Amp
Maximum Measurement Range
500V L-L 230V L-N, 5000 Amp
Nominal Current Input
CT Connect 3 x 5/1 Amp
Pulse Output
1Â x Passive (fixed)
Tariff Input
N/A
Accuracy
Class 1 (kWh Only)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
Alternatives
SDM630MCT
SDM72CT-M (with additional measurement parameters)
Modbus Utility
EEM Meter Setting Software Utility
Â
TRBM-22D-G-240, 22mm Pushbutton Momentary GREEN 240VAC, Metal, IEC60947-5-1
Pushbutton Switches will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24VAC/DC (400VAC Special Orders)
1 Pole Momentary
Rated for 6 Amp @ 230VAC, or 0.3 Amp @ 230VDC
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRBM-22D-G-240
Functions
Momentary
Colour
Black Body, Green Button
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Nominal Current Range AC
6 Amp @240VAC
Nominal Current Range DC
0.3 Amp @ 230VDC
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP40, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Â
Datasheet
Product Datasheet
Eastron SDM630MCT-1L 3 Phase DIN Rail Mount kWh Meter with Easyclick, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms
100mA RJ12 CT 4 x 3 Phase Connect
100mA RJ12 12 x Single Phase RJ12 CT with adapter
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
Easyclick CT system reduces installation costs
Dual Metering System Reduces Cost and saves space
Â
The meter is intended for measuring, and monitoring 1 x three phase or 3 x single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Â
Features :
System Accuracy Class B/Class1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM630MCT-1L
Functions
Quad Three Phase Energy Meter/ 12 x Single Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
415V L-L 230V L-N, 1/5 Amp +/-15%
Maximum Measurement Range
480V L-L 230V L-N, 1/5 Amp
Nominal CT Current Input
100mA via RJ12 Easyclick CT's
Pulse Output
N/A
Tariff Input
N/A
System Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
700g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Â
Documents
Product Datasheet
User Manual
Modbus Protocol
Suitable RJ12 CT's
Three Phase J12 Connected CT's
Split Core Single Phase CT's for RJ12 Connected Meters
Modbus Utility
EEM Meter Setting Software Utility