Fastron TC5-S-1A-2-T/R-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-S-1A-2-T/R-2
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Vishay VSKT105/16, Dual Thyristor Module, 105 Amp, 1600V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKT105/14
Vrrm
1600V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
105 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
1.785 kA
VF(to)
0.85V
Tj(max)
130°C
rF
2.25mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Faston A2.8 x 0.8mm
R th(j-c)
0.135°C/W
R th(c-h)
0.1°C/W
Weight
110g
Mounting Torque
5 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
OLD Product Datasheet
2018 Product Datasheet
Alternatives
See TT92N16K or TT104N14K for Infineon Pressure Contact Alternative, or for IXYS solder bonded Alternative MCC95-16
Fastron Electronics SCT-F16-175-5A, 175/5 Amp Measurement Split Core Current Transformer, 16mm Aperture
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-175-5A
Technology
Split Core AC Current Transformer
Ratio
175/5 Amp
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
175Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics SCT-F16-150-1A, 150/1 Amp Measurement Split Core Current Transformer, 16mm Aperture
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-150-1A
Technology
Split Core AC Current Transformer
Ratio
150/1 Amp
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
150Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
LEM ART-B22-D175-SP3, AC Measurement Rogowski Coil (coil only). 17.5cm Diameter, Class 0.5, 3M Shielded Cable Connection
Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). The patented Perfect Loop Technology dramatically reduces both the error due to the position of the measured conductor within the aperture, and the error due to the proximity of external conductors.
The ART series single phase flexible rope CT from LEM. In conjunction with AI-PMUL combined integrator & signal conditioner LEM offer True RMS 0-5V, 0-10V, 0-20mA, 4-20mA outputs, or direct linear outputs 0.333V or 0.166V
Included is a 17.5cm diameter rope CT, and 1.5M of twisted pair (1000V) output leads for connection to an integrator, or meter/logger with integration function.
LEM coils come with 5 year warranty
Features
Rated insulation voltage 1000 V Cat III PD2
Accuracy Class 0.5 (IEC 61869-2)
Protection degree IP67
? 70, ? 125, ? 175, ? 300 mm sensing aperture
3 m output cable (other lengths available see page 8)
Ambient temperature ?40 °C … +80 °C
Very flexible and thin coil: 6.1 mm
Slot for attaching the loop on the primary with a cable tie
? 2 mm hole to pass a security seal tampering
An innovative patented clasp drastically reduces the positioning error near the closing
Internal shield for enhanced measurement accuracy at low primary currents.
Advantages
Thin, flexible, and light weight solution
Very low positioning error
Quick, non-intrusive and easy setup
A single sensor for a large current range without overload
Less influenced by external fields
Adaptable for a large range of cable diameters
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012
1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012
1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016
UL
Specification
LEM Part Number
ART-B22-D175-SP3
Function
AC Current Measurement
Measuring Range
0 - 5,000 Amp RMS (Contact Us for Possible Replacement for wider range)
Secondary Voltage (Sensitivity)
22.5mV
Frequency Measuring Range
50-300kHz
Operating Voltage
Self Powered
Accuracy
0.5% from 25 to 5000 Amp
Phase Angle
< 0.004
Coil Diameter (?)
17.5cm
Coil Circumference
55cm
Integrator to Coil Cable
3M Twisted Pair
Maximum Voltage
1000V Reinforced insulation according to EN 61010-1
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
7.4kV
Overload
350,000 Amp
Termination Style
2 Stripped Wires
Weight
138g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
Product Datasheet
Application Notes
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modeling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
SI4P22242045080 Electrolytic Capacitor, Snap In, ø45 x 80mm 420V 2200uF +/-20% 105°C
Characteristics and utility
2200uF, 450V0.0kvar 20kvar
Electrolytic
Connector type - 4 Pin snap in
Indoor mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
LeClanche Part Number
SI4P22242045080
Technology
Electrolytic
Dimensions
ø45 x 80mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
420V
Operating Temperature Range
-40 to 105 °C
Capacitance
2200uF
Tolerance On Capacitance
+/- 20%
Lifetime
5000 Hours @ 105 °C
Termination Style
4 Pin Snap In Version
Unit Weight
0.25kg
Factory Pack Quantity
200
Datasheet
Product Datasheet
Alternative
SI4P22245045080 450V Version
Fastron Electronics SCT-F36-150-5A, 5 Amp, 150Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-150-5A
Technology
Split Core AC Current Transformer
Ratio
150/5 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
150Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
MS Power MSD83R16MB Series Stud Mount Rectifier Diode
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD83R16MB
Vrrm
1600V
Diode Configuration
Anode Stud
IF(av) @ 140 Deg C
85 Amp
Itsm
1.15 kA
VF(to)
0.85V
Tj(max)
180°C
rF
3mΩ
Termination Style (Tail)
8.2mm Round Lug
Termination Style (Stud)
M8 x 1
Tail Length to Stud
158mm
R th(j-c)
0.55°C/W
R th(c-h)
0.20°C/W
Weight
40g
Mounting Torque
4 Nm
Factory Pack Qty
10
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
Fastron FES2151-FP-V5, Split Core AC Current Transducer, Multirange 100A, 150A, 200A, Average RMS 0-5V Output. 1% Accuracy (FCS2151-FP-V5)
Compact and versatile current switches for detection of AC Currents, Multirange 0-100Amp, 0-150Amp, 0-200Amp via jumper, 0-5V True RMS output
Features
True RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FP-V5
Technology
Split Core AC Current Transducer
Range
Selectable 0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
0-5V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Iskra Doo K07MG-10/SP4-220/250VDC, AC Miniature Contactor 240/400/500/690V, with 220/250VDC Control Voltage, 4 Pole 4 x NO, Nominal Current = 11.3 Amps. SP4 = Version with 4 Main Contacts
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
K07MG-10/SP4-220/250VDC
Functions
4 Pole Contactor 4 x NO
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
15.5 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
220/250VDC
Power Dissipation
0.36W
Approvals
UL, CSA, CE
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
Trent NBR-CH14/UQ/20A/690V + RT18-63L Series 20 Amp 690V Semiconductor I²t gR Fuse & Din Rail Fuse Holder Cartridge Style 51 x 14mm
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 63 Amp
Quick Release with RT18-63L fuse holder
DIN Rail Mount with RT18-63L fuse holder
Compatible with all 51 x 14mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-CH14/UQ/20A/690V + RT18-63L
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
180 A²/s
Nominal Current (RMS + DC)
20 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
108mm x 77mm x 22mm
Fuse Holder
RT18-63L
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
13.8W
DC Breaking Capacity
50kA
Unit Weight
42g
Factory Pack Qty
10
Datasheet
Product Datasheet
RT18-63L
Schurter, 4430.2050 TA45-A624F160C0, 2 Pole Thermal Circuit Breaker Rocker Switch for Electrical Appliance, 240VAC/28VDC, 16 Amp
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Rocker Switch
Thermal circuit breaker
2-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4430.2050 TA45-A624F160C0
Functions
2 Pole Rocker Switch with 1 Pole Thermal Circuit Breaker
Nominal Voltage
240VAC @ 50Hz or 28VDC
Nominal Current Range
16 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Illumination
Transparent Green
Insulation Resistance
500VDC
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
100g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet