Fastron FDH12048RD3, Solid State Relay, 480VAC, 120 Amp, 3-32VDC Control, Random Crossing, Panel Mount, w/plastic Cover
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Specification
Fastron Part Number
FDH12048ZD3
Switching Type
Zero Crossing
CE
Yes
Control Voltage
3-32VDC
Load Current
120Amp (rms)
Surge Capability
1100 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
90-480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
250g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
RODN504015, Steel Enclosure, 500mmH x400mmW x 150mmD, IP66, RAL 7035 Gray 1.5mm Galvanised Steel
Features
Injected Polyurethane Sealing gasket
3 x M20 cable glands
4pcs Wall Mounts and dynabolts included
Lockable Door via Key
RAL7035 GREY AS3000/AS3100 Compliant
IP66
Â
Specification
Fastron Part Number
RODN504015
Function
Steel Water Proof Enclosure
Configuration
Enclosure with Hinged Door, Key Lock, 4 Mounting Clips, DYnabolts, and Cable Glands
Termination Style
Screw Mount to gear tray
Dimensions
H:500 x W:400 x D:150mm
Weight
12.4kg
Certification
AS 3000
AS 3100
Factory Pack Qty
1
Material of housing
1.5mm Galvanised Steel Painted RAL 7035
Enclosure protection
IP66
Operating Temperature
-20...55 °C
Datasheet
Datasheet
Fastron Electronics SCT-F24-300-40mA, 40mA, 300Amp measurement Split Core CT's, Class 1 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
40mA Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F24-300-40mA
Technology
Split Core AC Current Transformer
Ratio
300/40mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
40mAmp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics GTD-D-C-SP01, 0-60VDC Voltage Transducer/Transmitter, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-D-C-SP01
Control Output
4-20mA
Input
0 - 60VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
RCS-1200-0400, 0.333V 3 Phase 400Amp AC Measurement 4 Inch Rogowski Coils with Integrator, Class 1:
The RCS-1200 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Â
Specification
Magnelab Part Number
RCS-1200-0400
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
400 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 500 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
4 Inch
Coil Circumference
12 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
LEM HO 50-S-0100 Series Open Loop AC/DC Hall Effect Sensor
Features
Open loop current transducer
Voltage output
Single power supply +5 V
Overcurrent detect 2.93 × IP N (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
Factory calibrated
Compact design for panel mounting
Aperture: 15 × 8 mm
Factory calibrated
Repositionabel mounting foot
Dedicated parameter settings available on request
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 8 mm
Fast response
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-1: 1997
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007
IEC 62109-1: 2010
UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HO 50-S-0100
Technology
Open Loop Hall Effect
Aperture
15 x 8mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
50 Amp
Measurement Range
+/-125 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B5B-PH type
Unit Weight
32g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HAZ 6000-SB, Hall Effect Current Transducer, 6000A, +/-10V Instant Output, +/-15V supply
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
Features
Instantaneous output version +/-10V, +/-20mA
True RMS output versions 4-20mA, 0-10V putput
Hall effect measuring principle
Galvanic isolation between primary and secondary circuit
Instantaneous voltage output
Isolation voltage 17kV Rms /50 Hz /1min
Low power consumption
Package in PBT meeting UL 94-V0
Instantaneous voltage output
Advantages
Easy installation
Small size and space savings
Only one design for wide Ratings range
High immunity against external interference
Applications
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding and telecom applications
Application domain
Industrial
Traction
Specification
LEM Part Number
HAZ 6000-SB
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
+/- 15VDC
Load Current (RMS + DC)
6000 Amp
Overload Rating
30000 At
Output
+/-10 V Instantaneous
Isolation
17kV (AC, 50Hz, 1 min)
Bandwidth
DC-3kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
F2023A (FUJICON)
Unit Weight
6kg
Factory Pack Qty
2
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
DT9-216/AD240001, Dual Digital Time Switch with 2 independant Daily Weekly, Monthly, Yearly, Astro, Random program, Universal 24-240VAC/DC Power Supply/Control, 2 x 16 Amp SPST CO Relay
DT9-216/AD240001 UNI 24-240 V AC/DC - 2 Relay 16A :
Dual Timer
Multi-range (1 min - yearly)
Astro Timer Function
Random Timer Function
Multi-voltage 24 →240 V AC/DC
LED status indicator
Possibility of external load connection in parallel to the control input
Specification
Assudum Part Number
DT9-216/AD240001
Function
Daily, Monthly, Yearly, Astronomical, Random Time Switch
Nominal Voltage
24 → 240 V AC/DC
Digital Output
2 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Minutes, Hours, Days, Weeks, Months, Years, Astronomical, Sunset, Random
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
80g
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Â
Datasheet
Product Datasheet
Â
LEM HTR 50-SB, Open Loop Hall Effect Current Sensor, 50 Amp, +/-4V Output, Split Core 21mm Aperture, X = 2%
Features
Bandwidth DC to 10kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, 50 to 500 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
HTR 50-SB
Technology
Split Core Open Loop Hall Effect
Aperture
ø21mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
50 Amp
Measurement Range
+/-100 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 70°C
Accuracy
2%
Termination Style
Molex 5046-04A/AG
Unit Weight
80g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
SSPA-RED-4mm (2pcs), RED 4mm Fully Sheathed Piggy Back Safety/Banana Plugs For Test Equipment/Leads
32 Amp / 1000V AC (rms) or DC Maximum Rating
Fully Sheathed
4mm Piggy Back Plug Type
Suitable For Laboratory Test Equipment