Recommended products

4101 products

  • RJ12Cable-1SW, RJ12 Cable 1 Meter RJ12Cable-1SW, RJ12 Cable 1 Meter

    RJ12Cable-1SW, RJ12 Cable 1 Meter

    94 pcs in stock

    Eastron Europe RJ12Cable-1SW, RJ12 Cable 1 Meter Features Quick Release Split Core System Cable Mount 100mAmp or 100mV input and Output Applications Eastron Modular Metering Equipment   Specification Fastron Part Number RJ12Cable-1SW Technology Split Core AC Current Transformer Rating 100mV/100mA Bandwidth 50-60Hz Operating Temperature Range -15°C / 45°C Termination Style 1M Cable with RJ12 Connector Unit Weight 50g Factory Pack Qty 10   Application Notes Installation Guide CRJ-31 Connector User Guide

    94 pcs in stock

    $7.00
    $8.26 inclGST

  • Last stock! SCT-Y24-20A/100mA, 20A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter SCT-Y24-20A/100mA, 20A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter

    SCT-Y24-20A/100mA, 20A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter

    3 pcs in stock

    Fastron Electronics SCT-Y24-20A/100mA, 20A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter Features Quick Release Split Core System Cable Mount 100mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements   Specification Fastron Part Number SCT-Y24-20A/100mA Technology Split Core AC Current Transformer Ratio 20/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 20Hz, 1 min) Bandwidth 20-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 20Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide

    3 pcs in stock

    $52.00
    $61.36 inclGST

  • SDM630MCT-4L-TCP, Quad 3 Phase DIN Rail Mount kWh Meter with Easyclick, 4 x 3 Phase or 12 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms SDM630MCT-4L-TCP, Quad 3 Phase DIN Rail Mount kWh Meter with Easyclick, 4 x 3 Phase or 12 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms

    SDM630MCT-4L-TCP, Quad 3 Phase DIN Rail Mount kWh Meter with Easyclick, 4 x 3 Phase or 12 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms

    9 pcs in stock

    Eastron SDM630MCT-4L-TCP, Quad 3 Phase DIN Rail Mount kWh Meter with Easyclick, 4 x 3 Phase or 12 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms 100mA RJ12 CT 4 x 3 Phase Connect 100mA RJ12 12 x Single Phase RJ12 CT with adapter RS 485 communication up to 38,400 bit/s as standard True RMS values of currents and voltages Easyclick CT system reduces installation costs Dual Metering System Reduces Cost and saves space   The meter is intended for measuring, and monitoring 4 x three phase or 12 x single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.   Features : System Accuracy Class B/Class1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Graphic LCD with illumination Specification Eastron Part Number SDM630MCT-4L Functions Quad Three Phase Energy Meter/ 12 x Single Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 100mA via RJ12 Easyclick CT's Pulse Output N/A Tariff Input N/A System Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV RS485 2400-38400 b/s (400ms Response Time) Weight 700g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C   Documents Product Datasheet User Manual Modbus Protocol Suitable RJ12 CT's Three Phase J12 Connected CT's Split Core Single Phase CT's for RJ12 Connected Meters Modbus Utility EEM Meter Setting Software Utility

    9 pcs in stock

    $489.00
    $577.02 inclGST

  • 275.398-715401/221602 40KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 136 x 245(+47)mm Gas Filled (275.396-715401 +  Discharge Resistor), 3 x 154uF 275.396-715401/221K02 40KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 136 x 285mm Gas Filled-Power Factor Correction Capacitor-Electronicon-Fastron Electronics Store

    275.398-715401/221602 40KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 136 x 245(+47)mm Gas Filled (275.396-715401 + Discharge Resistor), 3 x 154uF

    152 pcs in stock

    Electronicon 275.398-715401/221602 40KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 136 x 245(+47)mm Gas Filled (This package includes Model#275.396-715401 +  Discharge Resistor) Characteristics and utility 25kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Gas Filled Lightweight Construction Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number 275.396-715401/221602 40KVAR 525V 50HZ, + 275.105.10120  Technology Gas Filled, Low Loss, Self Healing Dimensions 136 x 245(+47)mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 40 Kvar Capacitance 3 x 154uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 3 x 72 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal (Feed Through) Approvals UL 810, CSA C22.2 No.90 Unit Weight 3.2kg Factory Pack Quantity 25   Datasheet Product Datasheet Note we will supply 275.396-715401/221K02 with 275.105-10120 Discharge resistor. These are drop in replacements with 15mm lower height Application Notes Discharge Resistor Usage Power Factor Correction Blog

    152 pcs in stock

    $659.00
    $777.62 inclGST

  • FRTD-6-250-500 (ST5898), RTD Pt100 Class B, 150mm x 6mm Probe with 500mm of 3 wire cable, -50 to 350 Deg C-Temperature Sensor-Fastron Electronics-Fastron Electronics Store FRTD-6-250-500 (ST5898), RTD Pt100 Class B, 150mm x 6mm Probe with 500mm of 3 wire cable, -50 to 350 Deg C-Temperature Sensor-Fastron Electronics-Fastron Electronics Store

    FRTD-6-250-500 (ST5898), RTD Pt100 Class B, 150mm x 6mm Probe with 500mm of 3 wire cable, -50 to 350 Deg C

    18 pcs in stock

    Fastron FRTD-6-250-500 Resistance Temperature Detectors (RTD's) Class B Accuracy Pt100 output Teflon Screened Cable Low Long Term Drift Rated for -50 to 350 Deg C Max 250 x 6mm MIMS Recommended to use BSP Fitting for mounting Specification Fastron Part Number FRTD-6-250-500 Sensor Type RTD - Resistance Temperature Detectors No of Wires 3 Shaft Length 250mm Shaft Thickness 6mm Accuracy Class B Cable length 500cm Cable Type Teflon/Teflon Terminal Head Type N/A Maximum Temperature -50 to 350 Deg C Special Feature N/A Mounting Style BSP Bayonet or Flange Fitting Recommended Weight 300g Factory Pack Qty 1 Datasheet Datasheet

    18 pcs in stock

    $91.00
    $107.38 inclGST

  • SSPA-BLACK-4mm (2pcs), BLACK 4mm Fully Sheathed Piggy Back Safety/Banana Plugs, 32 Amp, 1000V Rated. For Test Equipment/Leads

    SSPA-BLACK-4mm (2pcs), BLACK 4mm Fully Sheathed Piggy Back Safety/Banana Plugs, 32 Amp, 1000V Rated. For Test Equipment/Leads

    25 pcs in stock

    SSPA-BLACK-4mm (2pcs), BLACK 4mm Fully Sheathed Piggy Back Safety/Banana Plugs, 32 Amp, 1000V Rated. For Test Equipment/Leads 32 Amp / 1000V AC (rms) or DC Maximum Rating Fully Sheathed 4mm Piggy Back Plug Type Suitable For Laboratory Test Equipment

    25 pcs in stock

    $7.90
    $9.32 inclGST

  • AI-PMUL + ART-B22-D175, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter-Rogowski Coil-LEM International SA-Fastron Electronics Store ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter

    ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter

    41 pcs in stock

    LEM ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number AI-PMUL + ART-B22-D125-SP3 Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

    41 pcs in stock

    $540.00
    $637.20 inclGST

  • Last stock! 88974161, Millenium 3 Essential XD26-16I/10O R, 16 x On/Off inputs, Incl 6 analogue inputs, 10 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Blue Display-Programmable Logic Controller-Crouzet Automation-Fastron Electronics Store

    88974161, Millenium 3 Essential XD26-16I/10O R, 16 x On/Off inputs, Incl 6 analogue inputs, 10 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Blue Display

    1 pcs in stock

    Crouzet 88974161, Millenium 3 Essential XD26-16I/10O R Programmable Logic Controllers, Blue Display Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Allow the use of the entire library of specific functions blocs of the software workshop Extended temperature range (-20 °C →+70 °C) Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters) Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions HMI Screens Available Specification Crouzet Part Number 88974161 (XD26-16I/10O R) Analogue Inputs 0-10VDC (x6) Digital Inputs 12/24VDC (4.4mA @ 12VDC) (x16) Digital Outputs Relay, 5-30VDC,24-250VAC @ 10mA minimum (x10) PWM SSR Output 12-24VDC @ 500mA (x4) Expandable Yes LCD Display Blue Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VDC (21.6 - 28.8VDC) Termination Style Screw Weight 350g Certification CE, UL, CSA, GL Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22   Datasheet Product Datasheet Selection Chart Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14

    1 pcs in stock

    $695.25
    $820.40 inclGST

  • KC50-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B KC50-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B

    KC50-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B

    15 pcs in stock

    Iskra Doo KC50-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KC50-12-230-50 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 27kVar/Amp @230VAC, 50kVar/Amp@480VAC, 50kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 2 x NC Trip Delay Time 2-10ms Electrical Life 100,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 1,000,000 Ops Control Voltage 230VAC Power Dissipation 5.1W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog

    15 pcs in stock

    $186.23
    $219.75 inclGST

  • KC25-11-230-50, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 33.3 kVar, 100,000 Operations, AC-6B KC25-11-230-50, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 33.3 kVar, 100,000 Operations, AC-6B

    KC25-11-230-50, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 33.3 kVar, 100,000 Operations, AC-6B

    16 pcs in stock

    Iskra Doo KC25-11-230-50, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 33.3 kVar, 100,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KC25-11-230-50 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 12.5kVar/Amp @230VAC, 25kVar/Amp@480VAC, 33.33kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 1 x NC Trip Delay Time 2-10ms Electrical Life 100,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 1,000,000 Ops Control Voltage 230VAC Power Dissipation 2W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog  

    16 pcs in stock

    $95.76
    $113.00 inclGST

  • SM-25-M6, Isolated Standoff 25mm x M6

    SM-25-M6, Isolated Standoff 25mm x M6

    75 pcs in stock

    Isolated Standoff 25mm x M6 Product Datasheet

    75 pcs in stock

    $7.00
    $8.26 inclGST

  • Last stock! SQ0214 L230V RC S6SS Synchroscope (Synchronoscope)

    SQ0214 L230V RC S6SS Synchroscope (Synchronoscope)

    1 pcs in stock

    Iskra Doo SQ0214 L230V RC S6SS Synchroscope (Synchronoscope) Measurement of phase difference between bus bar and generator Five instruments in one (SQ 0x14) Circular display of ∆ phase difference Magnifield display of phase difference ∆ = ±20 Microprocessor processing Simple synchronization conditions setting Output relay for synchronisation (pulse or continuous) ''Dead busbar or generator'' functionality Power supply from bus bar or generator Standard 96x96 mm or 144x144 mm din housing LCD with backlight for voltage, frequency and/or ∆ monitoring (SQ 0x14 only) High immunity to EMC disturbances Special functions set with three jumpers inside the instruments Status output Green led for indication of both voltages Ship version (Bureau veritas certificate - SQ 02x4)   Specification Iskra Doo Part Number SQ0214 L230V RC S6SS Function Phase Difference (∆ϕ) Measurement Nominal Voltage (Un) 230VAC ± 20 % Line to Line (UL-N = 400 VMAX) @ 40-70Hz Digital Output Relay 250 V, 1 A, 50 Hz, 250 VA Status Output Open-Collector 24 Vdc + 20% @30mA Switch On Delay Time Range 0,1 ... 1 s +/-10% Phase Difference Setting Range 2 ... 20 °el ± 3 °el Voltage Difference Setting Range 1 ... 10 % +/-2.5% Dead Busbar Noise Rejection Range 10%, 20%, 30% or 40% Power Consumption < 4VA Short Term Overload 2 x Un for 3 seconds LCD Display Accuracy Voltage 1.5%, Frequency 0.5%, Phase Difference +/-3 °el Synchronisation Accuracy +/- 10% Termination Style Screw Weight 530g Certification CE Factory Pack Qty 1 Enclosure Version Ship Version Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP52 for case, IP20 for terminals with protective cover Safety According to EN 61 010-1 400 V, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet User Manual Application Notes & Software Downloads The following parameters can be set via internal jumper see User Manual for more details. Dead Busbar Generator Function Over and Under Frequency Synchronising Adjustable Lenght of a Sync Pulse The following parameters Can be set via MIPack Comms Module & SQset Setting Software Relay - 300mS/Continuous/Programmable Dead Busbar - Active DB/Active DB + DG & % Threshold MIPack User Manual Download SQSet Settign Software

    1 pcs in stock

    $845.00
    $997.10 inclGST

Login

Forgot your password?

Don't have an account yet?