Eastron Europe RJ12Cable-1SW, RJ12 Cable 1 Meter
Features
Quick Release Split Core System
Cable Mount
100mAmp or 100mV input and Output
Applications
Eastron Modular Metering Equipment
Specification
Fastron Part Number
RJ12Cable-1SW
Technology
Split Core AC Current Transformer
Rating
100mV/100mA
Bandwidth
50-60Hz
Operating Temperature Range
-15°C / 45°C
Termination Style
1M Cable with RJ12 Connector
Unit Weight
50g
Factory Pack Qty
10
Application Notes
Installation Guide
CRJ-31 Connector User Guide
Fastron Electronics SCT-Y24-20A/100mA, 20A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter
Features
Quick Release Split Core System
Cable Mount
100mA Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads with HY-2.0 Connector
Applications
Eastron Modular Metering Equipment
Energy Monitoring
Load Balancing
Power Quality Measurements
Specification
Fastron Part Number
SCT-Y24-20A/100mA
Technology
Split Core AC Current Transformer
Ratio
20/100mA
Aperture Size
ø 24 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
100mA (+20%)
Isolation
3kV (AC, 20Hz, 1 min)
Bandwidth
20-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
20Amp x 1.2
Termination Style
0.9M Flying leads with HY-2.0 Connector
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
CRJ-31 Connector User Guide
Eastron SDM630MCT-4L-TCP, Quad 3 Phase DIN Rail Mount kWh Meter with Easyclick, 4 x 3 Phase or 12 x Single Phase, 240VAC aux, Class 1, 100mA RJ12 CT Connect, w/RS485 Modbus RTU Comms
100mA RJ12 CT 4 x 3 Phase Connect
100mA RJ12 12 x Single Phase RJ12 CT with adapter
RS 485 communication up to 38,400 bit/s as standard
True RMS values of currents and voltages
Easyclick CT system reduces installation costs
Dual Metering System Reduces Cost and saves space
The meter is intended for measuring, and monitoring 4 x three phase or 12 x single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
System Accuracy Class B/Class1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Graphic LCD with illumination
Specification
Eastron Part Number
SDM630MCT-4L
Functions
Quad Three Phase Energy Meter/ 12 x Single Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
415V L-L 230V L-N, 1/5 Amp +/-15%
Maximum Measurement Range
480V L-L 230V L-N, 1/5 Amp
Nominal CT Current Input
100mA via RJ12 Easyclick CT's
Pulse Output
N/A
Tariff Input
N/A
System Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
700g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Suitable RJ12 CT's
Three Phase J12 Connected CT's
Split Core Single Phase CT's for RJ12 Connected Meters
Modbus Utility
EEM Meter Setting Software Utility
Electronicon 275.398-715401/221602 40KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 136 x 245(+47)mm Gas Filled (This package includes Model#275.396-715401 + Discharge Resistor)
Characteristics and utility
25kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.396-715401/221602 40KVAR 525V 50HZ, + 275.105.10120
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
136 x 245(+47)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
40 Kvar
Capacitance
3 x 154uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 72 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal (Feed Through)
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
3.2kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Note we will supply 275.396-715401/221K02 with 275.105-10120 Discharge resistor. These are drop in replacements with 15mm lower height
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Fastron FRTD-6-250-500 Resistance Temperature Detectors (RTD's)
Class B Accuracy
Pt100 output
Teflon Screened Cable
Low Long Term Drift
Rated for -50 to 350 Deg C Max
250 x 6mm
MIMS
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FRTD-6-250-500
Sensor Type
RTD - Resistance Temperature Detectors
No of Wires
3
Shaft Length
250mm
Shaft Thickness
6mm
Accuracy
Class B
Cable length
500cm
Cable Type
Teflon/Teflon
Terminal Head Type
N/A
Maximum Temperature
-50 to 350 Deg C
Special Feature
N/A
Mounting Style
BSP Bayonet or Flange Fitting Recommended
Weight
300g
Factory Pack Qty
1
Datasheet
Datasheet
SSPA-BLACK-4mm (2pcs), BLACK 4mm Fully Sheathed Piggy Back Safety/Banana Plugs, 32 Amp, 1000V Rated. For Test Equipment/Leads
32 Amp / 1000V AC (rms) or DC Maximum Rating
Fully Sheathed
4mm Piggy Back Plug Type
Suitable For Laboratory Test Equipment
LEM ART-B22-D125-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 12.5cm Diameter
The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V.
2 selectable instantaneous output signals: 225 mV, 333 mV.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
AI-PMUL + ART-B22-D125-SP3
Function
Single Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon)
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-PMUL Datasheet
ART Series Datasheet
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Crouzet 88974161, Millenium 3 Essential XD26-16I/10O R Programmable Logic Controllers, Blue Display
Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting
More cost effective solution
Allow the use of the entire library of specific functions blocs of the software workshop
Extended temperature range (-20 °C →+70 °C)
Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters)
Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions
HMI Screens Available
Specification
Crouzet Part Number
88974161 (XD26-16I/10O R)
Analogue Inputs
0-10VDC (x6)
Digital Inputs
12/24VDC (4.4mA @ 12VDC) (x16)
Digital Outputs
Relay, 5-30VDC,24-250VAC @ 10mA minimum (x10)
PWM SSR Output
12-24VDC @ 500mA (x4)
Expandable
Yes
LCD Display
Blue
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VDC (21.6 - 28.8VDC)
Termination Style
Screw
Weight
350g
Certification
CE, UL, CSA, GL
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Selection Chart
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Iskra Doo KC50-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 27, 50, 50 kVar, 100,000 Operations, AC-6B
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
Capacitor Duty
Discharge Resistors
Three-pole contactors
Seven ratings from 12,5 kVAr to 60 kVAr
IEC 60947-4-1 for AC-6b utilization category
UL Approved
Advantages :
Conforms to utilization category AC-6b
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Switching of capacitor bank in parallel without de-rating
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KC50-12-230-50
Functions
3 Pole Capacitor Duty Contactor
Nominal Voltage
230/480/600VAC @ 50Hz
Current Carrying Capacity as per UL
27kVar/Amp @230VAC, 50kVar/Amp@480VAC, 50kVar/Amp@600VAC, AC-6B
Auxiliary Contacts
1 x NO and 2 x NC
Trip Delay Time
2-10ms
Electrical Life
100,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
1,000,000 Ops
Control Voltage
230VAC
Power Dissipation
5.1W
Approvals
UL
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Iskra Doo KC25-11-230-50, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 33.3 kVar, 100,000 Operations, AC-6B
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
Capacitor Duty
Discharge Resistors
Three-pole contactors
Seven ratings from 12,5 kVAr to 60 kVAr
IEC 60947-4-1 for AC-6b utilization category
UL Approved
Advantages :
Conforms to utilization category AC-6b
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Switching of capacitor bank in parallel without de-rating
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KC25-11-230-50
Functions
3 Pole Capacitor Duty Contactor
Nominal Voltage
230/480/600VAC @ 50Hz
Current Carrying Capacity as per UL
12.5kVar/Amp @230VAC, 25kVar/Amp@480VAC, 33.33kVar/Amp@600VAC, AC-6B
Auxiliary Contacts
1 x NO and 1 x NC
Trip Delay Time
2-10ms
Electrical Life
100,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
1,000,000 Ops
Control Voltage
230VAC
Power Dissipation
2W
Approvals
UL
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Iskra Doo SQ0214 L230V RC S6SS Synchroscope (Synchronoscope)
Measurement of phase difference between bus bar and generator
Five instruments in one (SQ 0x14)
Circular display of ∆ phase difference
Magnifield display of phase difference ∆ = ±20
Microprocessor processing
Simple synchronization conditions setting
Output relay for synchronisation (pulse or continuous)
''Dead busbar or generator'' functionality
Power supply from bus bar or generator
Standard 96x96 mm or 144x144 mm din housing
LCD with backlight for voltage, frequency and/or ∆ monitoring (SQ 0x14 only)
High immunity to EMC disturbances
Special functions set with three jumpers inside the instruments Status output
Green led for indication of both voltages
Ship version (Bureau veritas certificate - SQ 02x4)
Specification
Iskra Doo Part Number
SQ0214 L230V RC S6SS
Function
Phase Difference (∆ϕ) Measurement
Nominal Voltage (Un)
230VAC ± 20 % Line to Line (UL-N = 400 VMAX) @ 40-70Hz
Digital Output
Relay 250 V, 1 A, 50 Hz, 250 VA
Status Output
Open-Collector 24 Vdc + 20% @30mA
Switch On Delay Time Range
0,1 ... 1 s +/-10%
Phase Difference Setting Range
2 ... 20 °el ± 3 °el
Voltage Difference Setting Range
1 ... 10 % +/-2.5%
Dead Busbar Noise Rejection Range
10%, 20%, 30% or 40%
Power Consumption
< 4VA
Short Term Overload
2 x Un for 3 seconds
LCD Display Accuracy
Voltage 1.5%, Frequency 0.5%, Phase Difference +/-3 °el
Synchronisation Accuracy
+/- 10%
Termination Style
Screw
Weight
530g
Certification
CE
Factory Pack Qty
1
Enclosure Version
Ship Version
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP52 for case, IP20 for terminals with protective cover
Safety
According to EN 61 010-1 400 V, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Product Datasheet
User Manual
Application Notes & Software Downloads
The following parameters can be set via internal jumper see User Manual for more details.
Dead Busbar Generator Function
Over and Under Frequency Synchronising
Adjustable Lenght of a Sync Pulse
The following parameters Can be set via MIPack Comms Module & SQset Setting Software
Relay - 300mS/Continuous/Programmable
Dead Busbar - Active DB/Active DB + DG & % Threshold
MIPack User Manual
Download SQSet Settign Software