Fastron Electronics SCT-F16-20-5A-CL5, 5 Amp, 20Amp measurement Split Core CT's CLASS 5 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F16-20-5A-CL5
Technology
Split Core AC Current Transformer
Ratio
20/5 Amp
Aperture Size
ø 16 mm
VA Rating
N/A
Accuracy Class
Class 2
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
20Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Trent FGM6S-3P-250H 250A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal, Adjustable Type 50kA 250 Amp, 400/690VAC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Disconnect
50kA Short Circuit Rating @400VAC
Suitable for Main Incoming Breaker
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Trent Part Number
FGM6S-3P-250H 250A
Functions
MCCB
Nominal Voltage
400/690VAC @ 50/60Hz
Nominal Current Range
250 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
8kV
Operating Temperature
-25 to 50 Deg C
Mechanical Operations
20,000 Ops
Insulation Voltage
800V
Short Circuit Current
50kA
Approvals
KEMA EUR, CE
Standards
IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
1.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics SCT-F10-5, 5 Amp, 0.333v Class 1 Series Current Transformer, Equivalent to SCT-0400-10 (CE Approval, No UL approval)
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F10-5
Technology
Split Core AC Current Transformer
Ratio
5/0.333v
Aperture Size
ø 8 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
UL Approved Version
SCT-0400-05
Trent FGM6DC-2PL-320 125A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 125 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 125A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
125 Amps
Trip Delay Time
< 50ms
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu Ics=Icu
20kA @Â 1000VDC
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
CE Declaration
Fastron FRTD-Transmitter-0-400-420-24, Pt100 , 4-20mA Transmitter, 0 to 400 Deg C, 24VDC Supply
Class A Accuracy
Steel Insulated Cable
Low Long Term Drift
Rated for 0 to 220 Deg C Max
Spring Cable Connection
60mm Jaw Clip
Specification
Fastron Part Number
FRTD-Transmitter-0-400-420-24
Sensor Type
Pt100Â to 4-20mA Transmitter
No of Wires
3
Shaft Length
N/A
Shaft Thickness
N/A
Accuracy
Class B
Temperature Range
0 to 400 Deg C
Span/ Zero Adjustment
YES
Weight
50g
Factory Pack Qty
1
Fastron FGIR-32-C-24VDC, One Pole 1 x SPDT CO Bistable Relay with Manual Override 240VAC, 32 Amp, 24VDC Control Voltage, 50/60Hz
Features
32 Amp (rms) @ 240VAC
DIN Rail Mount
Slim package
CCC Compliant
IP20
Specification
Fastron Part Number
FGIR-32-C-24VDC
Switching Type
1 x SPDT CO
Approvals
CE
Coil Voltage
24VDC
Load Rating
32 Amp
Special Feature
Mounting Style
DIN Rail Mount
Load Voltage Range
240VAC 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Â
Datasheet
Datasheet
Crydom ED06C5, EMR plug in Solid State Relay, 18-32VDC control, 5 Amp 1-48V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED06C5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
18-32VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 48VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
TGLW30-3D25, 3 Pole Rotary/CAM Switch RED, 400VAC, Plastic, Direct Type, IEC60947-5-1
Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
400VAC in various Ratings
3 Pole 2 Position
64mm x 64mm Cutout
Standards :
IP40 Front, IP20 Terminals
IEC 60947-1,-3
IEC 60204
Specification
TRENT Part Number
TGLW30-3D25
Functions
3 Pole AC Disconnect CAM Switch
Nominal Voltage
400VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
25 Amp @400VAC
Rated Insulation Voltage
690VAC
Humidity
10-85%
Approvals
CE
Standards
IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed)
Weight
200g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Â
Datasheet
Datasheet
HS212F, Fan Cooled Heatsink 110mm, Milled, Drilled and Tapped for 3 Phase & Single Phase SSR, 0.35°C/W, 36 Amp per phase @ 40 Deg C for 3 Phase SSR
Datasheet
Product Datasheet