Fastron Electronics SCT-F16-100-33.3mA, 100/33.3mA Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-F16-100-33.3mA
Technology
Split Core AC Current Transformer
Ratio
100/33.3mAV
Aperture Size
ø 16 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
33.33mAÂ (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Trent FGM6DC-2PL-500 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 630 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-630 500A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
500 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
CE Declaration
Fastron FRV 8-04/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits
FRV 8 Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase 4 wire mains
Features
Upper and lower level of monitoring voltage
Adjustable time delay eliminates short voltage peaks and failures in the main
Supply is done from monitored voltage
Faulty state is indicated by red LED and by opening of output relay contact
Output contact 1 x Changeover / SPDT 10 A /250 V AC1
In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay
FRV8-04/460 - supply from all phases which means that relay is functional also in case when one phase is faulty
Variant FRV 8-04/265 - supply L1-N, means that relay monitors also failure of neutral wire
1-MODULE, DIN rail mounting
Specification
Technical Data
FRV 8
Supply and measuring
L1, L2, L3 (127,132,138,220,230,240,254,265VAC)
Supply terminals
L1, L2, L3
Supply/measured voltage
3 x 127-265 V (L-N) / 50 Hz
Level Umax
105 - 125 % Un
Level Umin
75 - 95 % Un
Burden
max. 2 VA
Hysteresis
2 %
Max. permanent overload
AC 3 x 265 V
Peak overload <1ms
AC 3 x 265 V
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
Â
Number of contacts
1 x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
Â
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE, CE
Datasheet
Product Datasheet
Fastron Monitoring/Time Relays Catalogue
For items in our catalogue which are not listed online please Contact Us for Possible Replacement
Application Notes
Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.
In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.
Rishabh Xmer CT Split 155/80 2000/5 Class 0.5 20VA Series Current Transformer
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
Rish Xmer 155/80 2000/5 SCCT Class 0.5 20VA
Technology
Split Core AC Current Transformer
Ratio
2000/5
Aperture Size
85 x 125mm
Burden
45VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
2000Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Rishabh Rish SIGMA 75 CTR5+5/5.CL1.15VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
Rish SIGMA 75 CTR5+5/5.CL1.10VA
Technology
AC Current Transformer
Ratio
5+5/5
VA Rating
10VA Class 1
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Â
Datasheet
Product Datasheet
Â
Northern Design Cube 400-M2-C Series 3 Phase Power Meter
Optional 2 Pulse Input or Outputs
Nominal current up to 6 A (For 5A CT Input) and nominal voltage up to 240V L-N
Three Line Display
Optional RS 232/RS 485 communication up to 19,200 bit/s
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Optional THD up to 15th Harmonic
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 1
Simple Menu
Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication
MODBUS and Ethernet communication protocol
240V AC power supply
Specification
Northern Design Part Number
Cube 400-M2-C
Functions
kWh Meter, Energy Meter
Supply Voltage
240VAC < 5VA
Nominal Measurement Range
415V L-L 240V L-N, 5 Amp
Maximum Measurement Range
415V L-L 280V L-N, 6 Amp
Display
Three Line LCD
Pulse Output
2 (input or output)
Accuracy
Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Ethernet
Modbus RTU Over TCP/IP 2400-19200 b/s
Weight
350g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Product Manual
Product Comms Manual
Application Notes
Dual Tariff Guide
CT Cable Losses
Meter Accuracy at Low Current
Current Input Isolation
Trent TC-FGM6DC-2P-400, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6DC-2P-400
Functions
Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker Frame Size 400
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent RT18-125L Series 690V Semiconductor I²t Fuse Holder 22 x 58mm, Fuse Ratings up to 125 Amp, Maximum Load Current = 90 Amp Continuous for gR, or aR type Fuses
Features
Cylindrical Standard Fuses Sizes
Finger Safe
IP 20 Protection
Optional Fuse Indicator
DIN Rail Mount
Modular
Lockable
IEC Standard 60269.2 AND 3
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
RT18-125L
Fuse Holder Type
IEC Fuse Holder
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
N/A
Nominal Current (RMS + DC)
125 Amp (90 continuous)
Tested Breaking Capacity
160kA @ 690VAC
Dimensions
123 x 76 x 35.5mm
Fuse Compatibility
To suit 22 x 58mm cylindrical fuse
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
N/A
DC Breaking Capacity
50kA
Unit Weight
70g
Factory Pack Qty
10
Â
Datasheet
Original Mersen Datasheet
Compatible Fuses
Equivalent to Mersen T331079
nbr-fr22aR69v25t
nbr-fr22aR69v40t
nbr-fr22aR69v63t
nbr-fr22aR69v80t
nbr-fr22aR69v125t
Schurter 3-103-712, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 12Amp, 250VAC, Very High Broadband Attenuation
Features
Line filter in standard and medical version
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
3-103-712
Rated Voltage
250V
Rated Current
12A
Filter Stages
1 Stage
Operating Temperature
-40°C to 100°C
Filter Type
Very High Broadband Attenuation
Leakage Current
0.5mA
Mounting
DIn Rail Mount Mount - Case RI
Material
Metal
Termination Style
Screw
Weight
140g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV L-N
VDE/UL/CSA/ROHS
Yes
Â
Datasheet
Product Datasheet
LEM AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
20-30VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ? 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 5 B420L
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
5 Amp
Maximum Measurement Current (RMS)
6 Amp
Output
4-20mA (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
55 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
1.5%
Aperture
? 16mm
Termination Style
Screw
Approvals
CE,UL,ROHS
Unit Weight
90g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron Electronics SCT-10-75, 75 Amp, 0.333v Class 1 Series Current Transformer
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F10-75
Technology
Split Core AC Current Transformer
Ratio
75/0.333v
Aperture Size
ø 8 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
75Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide