Recommended products

4101 products

  • Last stock! 11.216.996 AMJ5884 (AMJ5701) MAHLE - Letrika Unidirectional Clockwise 12VDC Motor, 1.6kW, 2750rpm 11.216.996 AMJ5884 (AMJ5701) MAHLE - Letrika Unidirectional Clockwise 12VDC Motor, 1.6kW, 2750rpm-DC Motor-MAHLE-Fastron Electronics Store

    11.216.996 AMJ5884 (AMJ5701) MAHLE - Letrika Unidirectional Clockwise 12VDC Motor, 1.6kW, 2750rpm

    2 pcs in stock

    ISKRA LETRIKA (MAHLE) 11.216.996 AMJ5884 (AMJ5701) Clockwise IM0117 12VDC Motor, 1.6kW, 2750rpm Used in BROC (OIL SISTEM) MAHLE Part # MM 61 ISKRA(Letrika) 11216996 IM0117 SMOES Specification ISKRA (MAHLE) Part Number 11.216.996 AMJ5884 (AMJ5701) ISKRA/LETRIKA/MAHLE 11.216.996 IM0117, 11216996, AMJ5884, MM61, 11216077, AMJ5701, 11212684, AMJ5189 Voltage 12VDC Power 1.6kW Rotation Unidirectional Rotation Speed 2750 rpm Unit Weight 6.9kg Factory Pack Qty 1 Datasheet Product Datasheet Cross Reference Manufacturer Manufacturer P/N ARROWHEAD LIA0004 BROC (OIL SISTEM) c162 0S1 002 SMOES CC12V1600W WESTERN MOTORS W-7864A Superseeded Link to Letrika Page Spare Parts Link to Letrika page

    2 pcs in stock

    $995.00
    $1,174.10 inclGST

  • SCT-F16-100, 100/0.333V Measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F16-100, 100/0.333V Measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F16-100-33.3mA, 100/33.3mA Measurement, Class 1 Split Core CT's

    28 pcs in stock

    Fastron Electronics SCT-F16-100-33.3mA, 100/33.3mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F16-100-33.3mA Technology Split Core AC Current Transformer Ratio 100/33.3mAV Aperture Size ø 16 mm VA Rating N/A Accuracy Class Class 1 Output 33.33mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    28 pcs in stock

    $45.00
    $53.10 inclGST

  • Last stock! FGM6DC-2PL-630 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1000VDC FGM6DC-2PL-630 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1000VDC

    FGM6DC-2PL-630 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1000VDC

    4 pcs in stock

    Trent FGM6DC-2PL-500 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 630 Amp, 1000VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 2 Pole Disconnect 20kA Short Circuit Rating @1000VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-2PL-630 500A Functions 2 Pole DC MCCB Nominal Voltage 1000VDC Nominal Current Range 500 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 20kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet CE Declaration

    4 pcs in stock

    $495.00
    $584.10 inclGST

  • FRV 8-04/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits FRV 8-04/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits-Monitoring Relay-Iskra Doo-Fastron Electronics Store

    FRV 8-04/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits

    267 pcs in stock

    Fastron FRV 8-04/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits FRV 8 Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase 4 wire mains Features Upper and lower level of monitoring voltage Adjustable time delay eliminates short voltage peaks and failures in the main Supply is done from monitored voltage Faulty state is indicated by red LED and by opening of output relay contact Output contact 1 x Changeover / SPDT 10 A /250 V AC1 In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay FRV8-04/460 - supply from all phases which means that relay is functional also in case when one phase is faulty Variant FRV 8-04/265 - supply L1-N, means that relay monitors also failure of neutral wire 1-MODULE, DIN rail mounting Specification Technical Data FRV 8 Supply and measuring L1, L2, L3 (127,132,138,220,230,240,254,265VAC) Supply terminals L1, L2, L3 Supply/measured voltage 3 x 127-265 V (L-N) / 50 Hz Level Umax 105 - 125 % Un Level Umin 75 - 95 % Un Burden max. 2 VA Hysteresis 2 % Max. permanent overload AC 3 x 265 V Peak overload <1ms AC 3 x 265 V Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output   Number of contacts 1 x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information   Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE, CE Datasheet Product Datasheet Fastron Monitoring/Time Relays Catalogue For items in our catalogue which are not listed online please Contact Us for Possible Replacement Application Notes Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines. In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.

    267 pcs in stock

    $65.00
    $76.70 inclGST

  • Last stock! Rishabh Instruments Split Core AC Current Transformer Rish Xmer 155/80 2000/5 Split Core CT Class 0.5 20VA FE-Rish Xmer 155/80 2000/5 SCCT Class 0.5 20VA Rish Xmer 155/80 2000/5 Split Core CT Class 0.5 20VA, 85 x 125mm Aperture

    Rish Xmer 155/80 2000/5 Split Core CT Class 0.5 20VA, 85 x 125mm Aperture

    3 pcs in stock

    Rishabh Xmer CT Split 155/80 2000/5 Class 0.5 20VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish Xmer 155/80 2000/5 SCCT Class 0.5 20VA Technology Split Core AC Current Transformer Ratio 2000/5 Aperture Size 85 x 125mm Burden 45VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet  

    3 pcs in stock

    $295.00
    $348.10 inclGST

  • Rish SIGMA 75 CTR5+5/5.CL1.15VA Summation Current Transformer

    Rish SIGMA 75 CTR5+5/5.CL1.15VA Summation Current Transformer

    9 pcs in stock

    Rishabh Rish SIGMA 75 CTR5+5/5.CL1.15VA Summation Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (30mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish SIGMA 75 CTR5+5/5.CL1.10VA Technology AC Current Transformer Ratio 5+5/5 VA Rating 10VA Class 1 Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 8 Amp Termination Style Screw Unit Weight 500g Factory Pack Qty 5   Datasheet Product Datasheet  

    9 pcs in stock

    $104.00
    $122.72 inclGST

  • Northern Design Electronics Ltd kWh Meter Cube 400-M2-C, Panel Mount kWh Meter, Class 1, 5Amp input, 2 pulse inputs or alarm/pulse outputs, RS485 Comms, Three line LCD Display FE-CUBE400-M2-C

    Cube 400-M2-C, Panel Mount kWh Meter, Class 1, 5Amp input, 2 pulse inputs or alarm/pulse outputs, RS485 Comms, Three line LCD Display

    9 pcs in stock

    Northern Design Cube 400-M2-C Series 3 Phase Power Meter Optional 2 Pulse Input or Outputs Nominal current up to 6 A (For 5A CT Input) and nominal voltage up to 240V L-N Three Line Display Optional RS 232/RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Optional THD up to 15th Harmonic The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS and Ethernet communication protocol 240V AC power supply Specification Northern Design Part Number Cube 400-M2-C Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 415V L-L 240V L-N, 5 Amp Maximum Measurement Range 415V L-L 280V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Ethernet Modbus RTU Over TCP/IP 2400-19200 b/s Weight 350g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Product Manual Product Comms Manual Application Notes Dual Tariff Guide CT Cable Losses Meter Accuracy at Low Current Current Input Isolation

    9 pcs in stock

    $598.00
    $705.64 inclGST

  • TC-FGM6DC-2P-400, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLY

    TC-FGM6DC-2P-400, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLY

    14 pcs in stock

    Trent TC-FGM6DC-2P-400, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLY  Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6DC-2P-400 Functions Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker Frame Size 400 Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    14 pcs in stock

    $15.00
    $17.70 inclGST

  • Trent gR Semiconductor Fuse Holder RT18-125L, Quick Release Fuse Holder/Cartridge for 25 to 125 Amp 22x58mm Fuse Links FE-RT18-125L RT18-125L, Quick Release Fuse Holder/Cartridge for 25 to 125 Amp 22 x 58mm Fuse Links-gR Semiconductor Fuse Holder-Trent-Fastron Electronics Store

    RT18-125L, Quick Release Fuse Holder/Cartridge for 25 to 125 Amp 22 x 58mm Fuse Links

    38 pcs in stock

    Trent RT18-125L Series 690V Semiconductor I²t Fuse Holder 22 x 58mm, Fuse Ratings up to 125 Amp, Maximum Load Current = 90 Amp Continuous for gR, or aR type Fuses Features Cylindrical Standard Fuses Sizes Finger Safe IP 20 Protection Optional Fuse Indicator DIN Rail Mount Modular Lockable IEC Standard 60269.2 AND 3 Applications Solid State Relay Switchboards Bridge rectifier Fusing Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number RT18-125L Fuse Holder Type IEC Fuse Holder Nominal Voltage 690VAC @ 50Hz I²t Rating (Pre-Arcing) N/A Nominal Current (RMS + DC) 125 Amp (90 continuous) Tested Breaking Capacity 160kA @ 690VAC Dimensions 123 x 76 x 35.5mm Fuse Compatibility To suit 22 x 58mm cylindrical fuse Mounting Style Din Rail Mount Operating Temperature Range -40°C / 125°C Watt Loss N/A DC Breaking Capacity 50kA Unit Weight 70g Factory Pack Qty 10   Datasheet Original Mersen Datasheet Compatible Fuses Equivalent to Mersen T331079 nbr-fr22aR69v25t nbr-fr22aR69v40t nbr-fr22aR69v63t nbr-fr22aR69v80t nbr-fr22aR69v125t

    38 pcs in stock

    $18.50
    $21.83 inclGST

  • 3-103-678, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 16Amp, 250VAC, Very High Broadband Attenuation-EMC Filter-Schurter-Fastron Electronics Store

    3-103-712, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 12Amp, 250VAC, Very High Broadband Attenuation

    12 pcs in stock

    Schurter 3-103-712, Din Rail Mount 2 Stage EMC (RFI) Line Filter, 12Amp, 250VAC, Very High Broadband Attenuation Features Line filter in standard and medical version 1-stage - standard attenuation Characteristics Designed for standard applications Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated Universal line filter for standard applications Suitable for use in equipment according to IEC/UL 60950 Other Versions on Request Version with wire connection Version with varistor for overvoltage protection Specification Schurter Part Number 3-103-712 Rated Voltage 250V Rated Current 12A Filter Stages 1 Stage Operating Temperature -40°C to 100°C Filter Type Very High Broadband Attenuation Leakage Current 0.5mA Mounting DIn Rail Mount Mount - Case RI Material Metal Termination Style Screw Weight 140g Factory Pack Qty 10 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Isolation 1.7kV L-N VDE/UL/CSA/ROHS Yes   Datasheet Product Datasheet

    12 pcs in stock

    $67.00
    $79.06 inclGST

  • Last stock! AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output

    AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output

    1 pcs in stock

    LEM AT 5 B420L, AC Current Transformer, loop powered, 5 Amp Average RMS 4-20mA output Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 20-30VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ? 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 5 B420L Technology AC Current Transformer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 5 Amp Maximum Measurement Current (RMS) 6 Amp Output 4-20mA (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 1.5% Aperture ? 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet

    1 pcs in stock

    $237.50
    $280.25 inclGST

  • SCT-F10-75, 0.333v, 75Amp Measurement, Class 1 Split Core CT's Class 1 SCT-F10-75, 0.333v, 75Amp Measurement, Class 1 Split Core CT's Class 1

    SCT-F10-75, 0.333v, 75Amp Measurement, Class 1 Split Core CT's Class 1

    144 pcs in stock

    Fastron Electronics SCT-10-75, 75 Amp, 0.333v Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 0.333v Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F10-75 Technology Split Core AC Current Transformer Ratio 75/0.333v Aperture Size ø 8 mm VA Rating N/A Accuracy Class Class 1 Output 0.333v (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 75Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide

    144 pcs in stock

    $39.00
    $46.02 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account