Recommended products

4102 products

  • XLG-240-H-AB, LED Driver/Power Supply with built in PFC, 240W, 100-305VAC input, 56VDC, 4.9Amp, Constant Current/Power/Voltage , Built In POT for Dimming with 0-10V PWM. IP67, Used as LED Driver

    XLG-240-H-AB, LED Driver/Power Supply with built in PFC, 240W, 100-305VAC input, 56VDC, 4.9Amp, Constant Current/Power/Voltage , Built In POT for Dimming with 0-10V PWM. IP67, Used as LED Driver

    7 pcs in stock

    XLG-240-H-AB, LED Driver/Power Supply with built in PFC, 240W, 100-305VAC input, 56VDC, 4.9Amp, Constant Current/Power/Voltage , Built In POT for Dimming with 0-10V PWM. IP67, Used as LED Driver Wide Supply Voltage: 100-305VAC Output Voltage: 56V Output Current: 4.9A Power Rating: 240W Short Circuit, Overload, Overcurrent, Overvoltage Protected PFC Feature PF>0.93 (93% Efficiency) UL, CE, ROHS Approved Datasheet Product Datasheet

    7 pcs in stock

    $97.00
    $114.46 inclGST

  • RCR-V30-60VDC, Earth Leakage Relay 30mA to 30 Amp Range 10-60VDC Supply, Din Rail Mount, 1 x SPDT ,1 x SPNO Relay, Suitable Replacement to Schneider VigiPacT RH10M

    RCR-V30-60VDC, Earth Leakage Relay 30mA to 30 Amp Range 10-60VDC Supply, Din Rail Mount, 1 x SPDT ,1 x SPNO Relay, Suitable Replacement to Schneider VigiPacT RH10M

    19 pcs in stock

    Fastron RCR-V30-60VDC, Earth Leakage Relay 30mA to 30 Amp Range 10-60VDC Supply, Din Rail Mount, 1 x SPDT ,1 x SPNO Relay, Suitable Replacement to Schneider VigiPacT RH10M Features : Suitable for Core Balanced CT's CTB 35, CTB 50, CTB 70, CTB 120, CTB 160, CTB 210 Suitable Replacement to Schneider VigiPacT RH10M Applications : AC Earth Leakage Detection Specification Hobut Part Number RCR-V30-60VDC Supply Voltage 10-60VDC @ 6VA Dimensions L:85mm x W:44mm xD:63.5mm Trip Setting Ranges 0.03,0.1,0.2,0.3,0.5,1,10,20,30 Amp Application Earth Leakage Detection Relay 1 x SPNO, 1 x SPDT Protection IP20 Approvals IEC 60755, 60947, 62020, 62543 Operating Temperature -20 to 55 Deg C Weight 200g Mounting Style Din Rail   Datasheet Product Datasheet User Manual Application Notes RCR-V30 Installation Guide

    19 pcs in stock

    $319.00
    $376.42 inclGST

  • Last stock! Rish SIGMA 75 CTR5+5/5.CL0.5.10VA Summation Current Transformer

    Rish SIGMA 75 CTR5+5/5.CL0.5.10VA Summation Current Transformer

    4 pcs in stock

    Rishabh Rish SIGMA 75 CTR5+5/5.CL0.5.10VA Summation Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (30mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number Rish SIGMA 75 CTR5+5/5.CL0.5.10VA Technology AC Current Transformer Ratio 5+5/5 VA Rating 10VA Class 0.5 Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 8 Amp Termination Style Screw Unit Weight 500g Factory Pack Qty 5   Datasheet Product Datasheet  

    4 pcs in stock

    $109.00
    $128.62 inclGST

  • CT 100/5 Class 0.5 2.5VA 50/21 (50), Current Transformer, ⌀ 21mm or 20x10mm Busbar CT 100/5 Class 0.5 2.5VA 50/21 (50), Current Transformer, ⌀ 21mm or 20x10mm Busbar

    CT 100/5 Class 0.5 2.5VA 50/21 (50), Current Transformer, ⌀ 21mm or 20x10mm Busbar

    33 pcs in stock

    Rishabh CT 100/5 Class 0.5 2.5VA 50/21 (50), Current Transformer, ⌀ 21mm or 20x10mm Busbar Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Rishabh Part Number CT 100/5 Class 0.5 2.5VA 50/21 (50) Technology AC Current Transformer Ratio 100/5 Aperture Size ⌀ 21mm or 20x10mm Busbar VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9   Datasheet Product Datasheet  

    33 pcs in stock

    $34.00
    $40.12 inclGST

  • LEM International SA Rogowski Coil AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input and Output, up to 5000Amp Measurement, Din Rail Mount FE-Integrator AI-PMUL

    AI-PMUL Universal Integrator for Rogowski Coils, Input (100 to 5000 Amp) and Output (0.333V,0.225V), and True RMS outputs (4-20mA,0-20mA,0-5V,0-10V), Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount

    41 pcs in stock

    LEM AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input (100 to 5000 Amp) and Output (0.333V,0.225), and True RMS outputs (4-20mA,0-20mA,0-5V,0-10V), Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both True RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. optional Input signal Accuracy Class 0.5 (IEC 61869-2) [1]. Linearity error ? 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature ?25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 0.5 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross power plugin connector: side contacts to stack up to 3 Integrator modules and use only one power supply. 24VDC Power Supply Meanwell HDR-15-24 Specification LEM Part Number AI-PMUL Function Integrator and True RMS Conditioner for Rogowski Coils Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 0.5% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm Mounting Din Rail Mount Integrator to Meter cable User Supplied Shielded cable 6mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet Product Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    41 pcs in stock

    $389.20
    $459.26 inclGST

  • ART-B22-D175-SP3 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter ART-B22-D175-SP3 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter

    ART-B22-D175-SP3 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter

    13 pcs in stock

    LEM ART-B22-D175-SP3 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coils & Universal Multi Range Integrator with Signal Conditioner The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D175-SP3 + AI-PMUL - 3 Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    13 pcs in stock

    $1,343.00
    $1,584.74 inclGST

  • Cube 400-M2, Panel Mount kWh Meter, 3 Phase, Class 1, 5Amp input, 240VAC aux, w/ pulse output

    Cube 400-M2, Panel Mount kWh Meter, 3 Phase, Class 1, 5Amp input, 240VAC aux, w/ pulse output

    9 pcs in stock

    Northern Design Cube 400-M2 Series 3 Phase Power Meter Optional 2 Pulse Input or Outputs Nominal current up to 6 A (For 5A CT Input) and nominal voltage up to 240V L-N Three Line Display Optional RS 232/RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Optional THD up to 15th Harmonic The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS and Ethernet communication protocol 240V AC power supply Specification Northern Design Part Number Cube 400-M2 Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 415V L-L 240V L-N, 5 Amp Maximum Measurement Range 415V L-L 280V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A (Optional 2400-19200 b/s) Weight 350g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Product Manual Product Comms Manual Application Notes Dual Tariff Guide CT Cable Losses Meter Accuracy at Low Current Current Input Isolation

    9 pcs in stock

    $584.00
    $689.12 inclGST

  • Last stock! H31/110M & FCR-400-40R, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-10V,500K POT Input, 400VAC, 25 Amp Per Phase-Solid State Relay Single Phase Angle Power Controller AC Load-Fastron Electronics-Fastron Electronics Store H31/110M & FCR-400-40R, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-10V,500K POT Input, 400VAC, 25 Amp Per Phase-Solid State Relay Single Phase Angle Power Controller AC Load-Fastron Electronics-Fastron Electronics Store

    H31/110M & FCR-400-60R, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-10V,500K POT Input, 400VAC, 25 Amp Per Phase @ 50 Deg C

    2 pcs in stock

    Fastron H31/110M & FCR-400-60R, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-10V,500K POT Input, 400VAC, 25 Amp Per Phase @ 50 Deg C 4-20mA,0-10V, or 500K POT Proportional Phase Control Input Ratings from 25A to 80 Amp @ 180-280 VAC SCR output for heavy industrial loads Instantaneous turn-on output Direct bond copper substrate Direct power lead frame Epoxy free design Specification Trent part Number H31/110M & FCR-400-60R Switching Type Phase Angle (Random Crossing) Control Voltage 4-20mA,0-10V,500K POT Proportional Input Load Current 25 Amp (rms) @ 50 Deg C, 30 Amp Per phase @ 40 Deg C Surge Capability 500Amp (peak) Special Feature 3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator Mounting Style Panel Mount Load Voltage Range 180-400VAC +10% Max Non Repetitive Peak Voltage 600 Vp Termination Style Barrier Strip Screw Dimensions L:110 x W:125 x D:180mm Unit Weight 2kg Factory Pack Qty 20   Datasheet FCR-400-60R Product Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here

    2 pcs in stock

    $405.00
    $477.90 inclGST

  • HTA 200-S, O/L Hall Effect Current Sensor, 200 Amp, +/-4V Output

    HTA 200-S, O/L Hall Effect Current Sensor, 200 Amp, +/-4V Output

    50 pcs in stock

    LEM HTA 200-S Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 1000 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTA 200-S Technology Open Loop Hall Effect Aperture ø32mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/-600 Amp Output +/-4 V Isolation 4 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 230g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    50 pcs in stock

    $147.35
    $173.87 inclGST

  • DVL 2000, Digital Voltage Transducer 2000V, +/-15...24VDC Supply, 50mA Output, 8.5kV Isolation

    DVL 2000, Digital Voltage Transducer 2000V, +/-15...24VDC Supply, 50mA Output, 8.5kV Isolation

    36 pcs in stock

    LEM DVL 2000 Series Closed Loop AC/DC Digital Voltage Transducer 2000V Input, 50mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    36 pcs in stock

    $565.00
    $666.70 inclGST

  • LT 2005-S, C/L Current Transducer, Ipn = 2000A, +/-15/24VDC, 400mA Output, X = 0.3%

    LT 2005-S, C/L Current Transducer, Ipn = 2000A, +/-15/24VDC, 400mA Output, X = 0.3%

    13 pcs in stock

    LEM LT 2005-S, C/L Current Transducer, Ipn = 2000A, +/-15/24VDC, 400mA Output, X = 0.3% Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 2005-S Technology Closed Loop Hall Effect Aperture ø60.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/- 3000 Amp Output 400 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.3% Termination Style M5 theaded studs Unit Weight 0.55kg Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    13 pcs in stock

    $1,029.00
    $1,214.22 inclGST

  • 300UR120D M20, Rectifier Diode, 300 Amp, 1200V M20, Anode to stud

    300UR120D M20, Rectifier Diode, 300 Amp, 1200V M20, Anode to stud

    92 pcs in stock

    International Rectifier 300UR120D M20, Rectifier Diode, 300 Amp, 1200V M20, Anode to stud Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification International Rectifier Part Number 300UR120D M20 Vrrm 1200V Diode Configuration Cathode Stud IF(av) @ 100 Deg C 400 Amp IF(av) @ 150 Deg C 300 Amp Itsm 6.55 kA VF(to) 0.61V Tj(max) 200°C rF 0.751mΩ Termination Style (Tail) 8.3mm Round Lug Termination Style (Stud) M20 x 1.5P Tail Length to Stud 149mm R th(j-c) 0.18°C/W R th(c-h) 0.08°C/W Weight 250g Mounting Torque 26 Nm Factory Pack Qty 8 Datasheet Product Datasheet

    92 pcs in stock

    $48.00
    $56.64 inclGST

Login

Forgot your password?

Don't have an account yet?