300U120D M20, Rectifier Diode, 300 Amp, 1200V, M20, Cathode to stud
International Rectifier 300U120D M20, Rectifier Diode, 300 Amp, 1200V, M20, Cathode to stud Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification International Rectifier Part Number 300U120D M20 Vrrm 1200V Diode Configuration Cathode Stud IF(av) @ 100 Deg C 400 Amp IF(av) @ 150 Deg C 300 Amp Itsm 6.55 kA VF(to) 0.61V Tj(max) 200°C rF 0.751mΩ Termination Style (Tail) 8.3mm Round Lug Termination Style (Stud) M20 x 1.5P Tail Length to Stud 149mm R th(j-c) 0.18°C/W R th(c-h) 0.08°C/W Weight 250g Mounting Torque 26 Nm Factory Pack Qty 8 Datasheet Product Datasheet
$48.00
$56.64 inclGST -
IKA232-20-R-230VAC, Iskra Two Pole 2 x SPST NO Modular Contactor 240VAC 32 Amp, 230VAC Control Voltage, with Manual Overide
Iskra IKA232-20-R-230VAC, Iskra Two Pole 2 x SPST NO Modular Contactor 240VAC 32 Amp, 230VAC Control Voltage, with Manual Overide Features 32 Amp (rms) @ 240VAC DIN Rail Mount Changeover Contact Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number IKA232-20-R-230VAC Switching Type 2 x SPST NO Approvals CE Coil Voltage 230/240VAC Load Rating 32 Amp Special Feature Manual Overide Mounting Style DIN Rail Mount Load Voltage Range 240VAC Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Â Datasheet Contactor Datasheet
$42.00
$49.56 inclGST -
SCT-F36-100, 0.333V, 100Amp Measurement, Class 1 Split Core CT's, 35mm Aperture
Fastron Electronics SCT-F36-100, 0.333V, 100Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-100 Technology Split Core AC Current Transformer Ratio 100/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
D2440, Solid State Relay, Single Phase 3-32VDC Control, 40A, 24-280VAC Load
Crydom D2440, Solid State Relay, Single Phase 3-32VDC Control, 40A, 24-280VAC Load Features Ratings from 25A to 125 Amp @ 24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D2440 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 3-32VDC Load Current 40 Amp (rms) Surge Capability 597 Amp (peak) Special Feature None Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Â Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent D2450 HD4850 CY9008 CWD2450P HD6050 App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$93.00
$109.74 inclGST -
HS212, Heatsink 110mm, Milled, Drilled and Tapped for Single & 3 Phase SSR, 1°C/W
HS212, Heatsink 110mm, Milled, Drilled and Tapped for Single & 3 Phase SSR, 1°C/W Specifications 3 x 20 Amp @ 40 Deg C Panel Mount Datasheet Product Datasheet Heatsink products are mostly made to order and require 2-3 days more to produce.Â
$49.00
$57.82 inclGST -
GV200PA-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 12/24VDC External Economiser Coil, 38cm Flying leads, WITHOUT Auxiliary Contact, IP67
Gigavac GV200PA-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 12/24VDC External Economiser Coil, 38cm Flying leads, WITHOUT Auxiliary Contact, IP67 Features External Economiser Coil (Requires External Economser) Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV200PA-1 Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 12/24VDC Economiser Load Current 500+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature External Economiser Coil (No Internal Economiser) Mounting Style Panel Mount (M5) Load Voltage Range 12 - 800VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
$232.99
$274.93 inclGST -
FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation
Fastron FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 24VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 5 B420L Technology AC Current Transformer Protection Class IP50 Supply Voltage 24VDC Loop Powered (10mA) Load Current (RMS) 5 Amp Maximum Measurement Current (RMS) 6 Amp Output 4-20mA (Average RMS) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50 - 400Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 0.5% Aperture 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 140g Factory Pack Qty 6  Datasheet Product Datasheet Â
$82.00
$96.76 inclGST -
PSD35T/18, 3 Phase Diode rectifier Bridge, 35 Amp, 1800V
Powersem PSD35T/18 Single Phase Half Controlled Rectifier Bridge, Replaces Semikron SKD30/18 Features Package with DCB ceramic base plate Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL registered, E 148688 Applications Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Powersem Part Number PSD35T/18 AC Line voltage 600V Device Configuration Three Phase Diode Rectifier Bridge DC Output @ 85 Deg C 38 Amp Package Size W:55mm L:45mm D:24mm Itsm 400 A VF(to) 0.85V Tj(max) 150°C rF 12mΩ Terminals M4 (1.5Nm) Hole Centres 45mm (M4) Gate Terminals N/A R th(j-c) 2.8°C/W R th(c-h) 0.6°C/W Weight 110g Isolation 3kV Factory Pack Qty 10 Certification UL Listed Powersem Headquarters Germany  Datasheet Product Datasheet Alternatives See PSD55T/16 or PSD51/18 for higher rated equivalent Â
$47.60
$56.17 inclGST -
PV10-30A1000VDCgPV, AEO 10.3x38 GpV Solar Fuse 30Amp, 1000VDC @ 10kA, UL2579, IEC 60269, GB13539
PV10-30A1000VDCgPV, GpV Solar Fuse 30Amp, 1000VDC @ 10kA, UL2579, IEC 60269, GB13539 Features Meets the new UL and IEC photovoltaic standards UL Recognized for 1000 VDC High breaking capacity of 10 kA @ 1000 VDC Low min. interrupting rating of 1.35 x In Meets the requirements of IEC 61730-2 for PV module safety Applications All photovoltaic applications Inverters Battery charge controllers In-line protection String fuses  Specification Vicfuse Part Number 8020.2053 Fuse Type I²t GpV Class Fast Blow Nominal Voltage 1000VDC, 275VAC I²t Rating (Pre-Arcing) 3150 A²/s Nominal Current (DC) 30 Amp Tested Breaking Capacity 10kA @1000VDC Dimensions 10.3 x 38mm Fuse Holder FSO Fuse Holders, VCB10-30 Mounting Style Requires fuse holder Operating Temperature Range -40°C / 125°C Watt Loss 1.8W DC Breaking Capacity 10kA Unit Weight 8g Factory Pack Qty 10  Datasheet Product Datasheet Compatible Fuse Holder FSO Fuse Holders VCB10-30 Â
$9.50
$11.21 inclGST -
SCT-F16-100-40mA, 40mA, 100Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100-40mA, 40mA, 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 40 mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F16-100-40mA Technology Split Core AC Current Transformer Ratio 100/40mA Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 0.5 Output 40 mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$48.00
$56.64 inclGST -
SCT-F50-600, 0.333V, 600Amp measurement Split Core CT's
Fastron Electronics SCT-F50-600, 0.333V, 600Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F50-600 Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 600g Factory Pack Qty 9  Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
LA25F1 90-264VAC, Hours Run Meter 90-264VAC, 48x48mm Panel Mount
GIC Controls, LA25F1 90-264VAC, Hours Run Meter 90-264VAC, 48x48mm Panel Mount  Features IP40 (IP66 with Gasket) 90-264VAC 6 Digit Display 99999.9 Hours 48x48mm Panel Mount Rectangular Cutout UL Approved Datasheet Product Datasheet
$35.00
$41.30 inclGST