Fastron Electronics HF121-12/0.4-40-7%K, 40kVar 400VAC(0.95mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.95mH(400VAC) 1.526mH(525VAC)
Specification
Technical Features
HF121-12/0.4-40-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
0.95mH
Inductance (mH @ 525VAC)
1.526mH
Nominal Power
40kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
25kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
HF121-12/0.4-16.7-7%K, 16.7kVar 400VAC 7% Detuned Reactor for Power Factor Correction Capacitor Banks
Specification
Technical Features
HF121-12/0.4-16.7-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
3.678mH
Inductance (mH @ 525VAC)
Nominal Power
16.7kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
21kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Trent FRS7-B+C 37.5/440 (3+0)R, Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD), 3 Pole 37.5kA (12.5kA per pole), 440VAC, DIN Rail Mount, With Remote Contacts, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Specifications
Â
Trent part number
FRS7-B+C 37.5/440 (3+0)R
Nominal Voltage (Un) L-L
400VAC
Maximum Voltage (Uc) L-L
440VAC
No of Poles
3
Voltage Protection Level (Up)
< 2.2kV
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Additional Remote Contacts
YES
Protective element
MOV + GDT
Surge discharge rating
Imax up to 50 kA, or 12.5kA per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Â
Datasheet
Product Datasheet
TRI-22-W240, 22mm LED Indicator WHITE 240VAC, Plastic, IP65, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
240VAC or 24VAC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Long Life
Replacement Beads Available
Standards :
IP65
IEC60947-5-1
CE
Specification
TRENT Part Number
TRI-22-W240
Functions
LED Indicator Only
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
White/Clear LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TRI-22-W24, 22mm LED Indicator WHITE 24VAC/DC, Plastic, IP65, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
24VAC/DC or 24VAC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Long Life
Replacement Beads Available
Standards :
IP65
IEC60947-5-1
CE
Specification
TRENT Part Number
TRI-22-W24
Functions
LED Indicator Only
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
White/Clear LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TGD-22SM-R-230, 22mm RED LED Flasher/Indicator and Audible Alarm Buzzer, 240VAC, Plastic
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
240VAC Supply
LED Illumination
Ø 22.5mm Cutout
Long Life
LED Replacement Beads Available
RED, GREEN, AMBER, BLUE, or Clear\White Colour
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TGD-22SM-R-230
Functions
LED Indicator and Audible Alarm
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
RED LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Â
Datasheet
Product Datasheet
Trent UV-FGM6S-160-230V 100A, Undervoltage Release, Right Side Mount for Moulded Case Circuit Breaker (MCCB) Frame Size 160Â
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Undervoltage Release, Right Side Mount
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
UV-FGM6S-160-230V 100A
Functions
MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent UV-FGM6S-250-230V, Undervoltage Release, Right Side Mount for Moulded Case Circuit Breaker (MCCB) Frame Size 250
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Undervoltage Release, Right Side Mount
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
UV-FGM6S-250-230V
Functions
MCCB
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent ROT-FGM6-800, Extended Rotary Handle for 3 POLE MCCB FGM6-800 Frame Size
Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Rotary handle mounts directly on MCCB with screws (included) without removal of midcover
Clear ON/OFF/TRIP
SuDirect access to push to trip button with rotary handle mounted
Datasheet
Product Datasheet
Trent ROT-FGM6-630, Extended Rotary Handle for 3 POLE MCCB FGM6-630 Frame Size
Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Rotary handle mounts directly on MCCB with screws (included) without removal of midcover
Clear ON/OFF/TRIP
Direct access to push to trip button with rotary handle mounted
Datasheet
Product Datasheet
Trent ROT-FGM6-400, Extended Rotary Handle for 3 POLE MCCB FGM6-400 Frame Size
Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Rotary handle mounts directly on MCCB with screws (included) without removal of midcover
Clear ON/OFF/TRIP
Direct access to push to trip button with rotary handle mounted
Datasheet
Product Datasheet
Trent ROT-FGM6-160, Extended Rotary Handle for 3 POLE MCCB FGM6-160 Frame Size
Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Rotary handle mounts directly on MCCB with screws (included) without removal of midcover
Clear ON/OFF/TRIP
Direct access to push to trip button with rotary handle mounted
Datasheet
Product Datasheet