Schurter FMAC-0934-3610, 1 Stage EMC (RFI) Line Filter for 3-Phase 3 Wire Solar or Industrial Systems, 36 Amp, 480VAC
Features
3 phase line filter with standard attenuation
Available as high voltage filter (up to 520 VAC)
Applications
Voltage rating 480 and 520 VAC for world wide acceptance
Protection against interference voltage from the mains
For photovoltaic systems and industrial applications
Suitable for use in equipment according to IEC/UL 60950
Specification
Schurter Part Number
FMAC-0934-3610
Rated Voltage
480V
Rated Current
25A
Filter Stages
1 Stage (3 Phase)
Operating Temperature
-25°C to 85°C
Connection
3 Wire + Earth
Filter Type
Excellent Attenuation
Leakage Current
5mA
Mounting
Panel Mount - Case 32-7
Material
Metal
Termination Style
Screw
Weight
4kg
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
2.2kV
VDE/UL/CSA/ROHS
Yes
Â
Datasheet
Product Datasheet
Â
H31/110M-FCR, Heatsink 110mm, Milled, Drilled and Tapped for FCR Series 3 Phase Phase Control Module, 0.5°C/Watt
Product Datasheet
Heatsink products are mostly made to order and require 2-3 days more to produce.
H31/110M-F, Fan Cooled Heatsink 110mm, Milled, with 95 Deg C NC Thermal Switch, 0.15°C/Watt
Product Datasheet
Heatsink products are mostly made to order and require 2-3 days more to produce.
Rincon Power RECNC46B1Q, DC Contactor SPST-NC, 400 Amp Continuous, 1000VDC, 24VDC Coil (Dual Economised), SPST-NO Auxiliary Contact, Exceeds IP69
Features
Hermetically Sealed (Patented) rated to 175 Deg C
Gas Filled
Normally Closed
Exceeds IP69
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
Built in dual Coil suppression for all DC Coils
Flexible package for installation
Specification
Rincon Power Part Number
RECNC46B1QA
Main Contact Type
SPST-NC
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC (Economised)
Load Current
400 Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
1000VDC
Standards
IEC60947-4-1 compliant, Meets RoHS 2011/65/EU
Termination Style
M12
Unit Weight
430g
Factory Pack Qty
24
Â
Datasheet
Product Datasheet
Fastron FC5-S-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-1U-2-G-4
Control Output
0-10V
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 x Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Â
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Fastron Electronics SCT-Y24-10A/100mA, 10A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter
Features
Quick Release Split Core System
Cable Mount
100mA Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads with HY-2.0 Connector
Applications
Eastron Modular Metering Equipment
Energy Monitoring
Load Balancing
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-Y24-10A/100mA
Technology
Split Core AC Current Transformer
Ratio
10/100mA
Aperture Size
ø 24 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
100mA (+20%)
Isolation
3kV (AC, 10Hz, 1 min)
Bandwidth
10-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
10Amp x 1.2
Termination Style
0.9M Flying leads with HY-2.0 Connector
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
CRJ-31 Connector User Guide
Fastron FPC1-63-04C-230VAC, 4 Pole 4 x SPST NC, Modular Contactor 440VAC 63 Amp 50/60Hz, 230VAC Coil Voltage, Hum Free
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
FPC1-63-04C-230VAC/DC
Switching Type
4 x SPST NC
Approvals
CE
Coil Voltage
230VAC/DC, 50/60HzÂ
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC, 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Â
Datasheet
Relay Datasheet
Auxiliary Contacts Selection Guide
FFRS3-C40-1500R-T2, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
Â
Specifications
Trent part number
FRS3-C40-1500R
Nominal Voltage
1500VDC
No of Poles
3
Category IEC / EN / VDE
Type 2 (Class II)
Location of use
String Box, Inverter, Sub Board Only
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES NO/NC/COM
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA)Â Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC614643-31:2018 (TUV, CE Approved)
Â
Datasheet
Product Datasheet
GDT/MOV/TVSÂ Tester
SPD Tester
BLR-CM12R3PHASE (3ACM06R-BEL-O 3PHASE), Power Factor Regulator, 12 Step, 3 Phase Measurement, 3 Phase or Single Phase Control of 3 phase Circuit, 50-530V 50/60HZ (OBSOLETE 2025)
Three CT Sensing
32nd Harmonic Measurement
Load balancing
Isolated Switching of Power Factor Correction Contactors
Cos Ï• Setting 0.9 to 0.9 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 12 steps
Measurement System - Automatic/Manual
50-530VAC Measurement
100-132V / 207-253VAC (L-N) Aux Supply
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
Â
Specification
Beluk Part Number
BLR-CM12R / 3ACM06R-BEL-O 3PHASE
Function
Reactive Power Correction / Load Balancing
Nominal Voltage (Un)
50-530VAC Line to Line
Supply Voltage
100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A
Relay Rating
250VAC/5Amp
Static Output Rating (T Models)
8-48VDC / 100mA
Internal 2MB LoggerÂ
Optional
3 x CT MeasurementÂ
Included
Switch Delay Time
1s - 1200s User Adjustable
Alarm
1 x Relay as above
Temperature/Fan/THD Alarm
1 x Relay as above
Re-connection Delay Time
50 - 1200s User Adjustable
Desired Power Factor
0.90 IND - 0.90 CAP
Number of Output Relays
12
Smallest Capacitor Current
10mA
CT Input Range
15mA - 6 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
Optional
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
User Manual
Modbus user Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)
ACXP06R-MB (BLR-CX Plus 12R-MB), CX-Plus Power Factor Regulator, 12/13 Step, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Modbus RTU Comms, Step Time Recording, Alarm Recording, RS485 Modbus
Single CT Sensing
Isolated Switching of Power Factor Correction Contactors
Cos Ï• Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 13 steps
Measurement System - Automatic/Manual
90-550VAC Aux/Measurement Supply
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
Â
Specification
Beluk Part Number
ACXP12R-MB (BLR-CX Plus 12R-MB) / Â 3ACXP12R-BEL-G-MB
Function
Reactive Power Correction
Nominal Voltage (Un)
110-480VAC Line to Line
Supply Voltage
90-300VAC (L-N), 15VA 45-65Hz
Relay Rating
250VAC/10Amp
Switch Delay Time
1s - 1200s User Adjustable
Alarm
1 x Relay as above
Temperature/Fan Alarm
1 x Relay as above (Can be used as 13th Step)
Re-connection Delay Time
50 - 1200s User Adjustable
Desired Power Factor
0.80 IND - 0.80 CAP
Number of Output Relays
6
Smallest Capacitor Current
10mA
CT Input Range
5mA - 6 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485 Modbus
Termination Style
Screw
Weight
700g
Certification
IEC 654-1
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
User Manual
Modbus user Manual
Comparison of CX and CX Plus Controllers
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)