Recommended products

4100 products

  • Last stock! ACMKP525.3.20.00, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 12.5KVAR @ 415VAC, 3 x 77uF ACMKP525.3.20.00, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 12.5KVAR @ 415VAC, 3 x 77uF

    ACMKP525.3.20.00, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 12.5KVAR @ 415VAC, 3 x 77uF

    1 pcs in stock

    Vishay ACMKP525.3.20.00, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 12.5KVAR @ 415VAC, 3 x 77uF Characteristics and utility 20kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Vishay Part Number ACMKP525.3.20.00 Technology Gas Filled, Low Loss, Self Healing Dimensions 85 x 265mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 25 Kvar Size 85 x 265mm Capacitance 3 x 77uF (12.5KVAR @ 415VAC) Tolerance On Capacitance -5% + 10% (others on request) Current (In) 22 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 1.7kg Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog

    1 pcs in stock

    $174.00
    $205.32 inclGST

  • Last stock! ACXP12T-MB-D (BLR-CX Plus 12T-MB-D), CX-Plus Power Factor Regulator, 12/13 Step SOLID SATE OUTPUTS, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Modbus RTU Comms, Step Time Recording, Alarm Recording, RS485 Modbus, with Internal Data Logger

    ACXP12T-MB-D (BLR-CX Plus 12T-MB-D), CX-Plus Power Factor Regulator, 12/13 Step SOLID SATE OUTPUTS, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Modbus RTU Comms, Step Time Recording, Alarm Recording, RS485 Modbus, with Internal Data Logger

    1 pcs in stock

    ACXP12T-MB-D (BLR-CX Plus 12T-MB-D), CX-Plus Power Factor Regulator, 12/13 Step SOLID SATE OUTPUTS, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Modbus RTU Comms, Step Time Recording, Alarm Recording, RS485 Modbus, with Internal Data Logger Single CT Sensing Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 13 steps Measurement System - Automatic/Manual 90-550VAC Aux/Measurement Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number ACXP12T-MB-D (BLR-CX Plus 12T-MB-D) / 3ACXP12T-BEL-G-MB-D Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 90-300VAC (L-N), 15VA 45-65Hz Relay Rating SOLID STATE TRANSISTOR OUTPUT Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan Alarm 1 x Relay as above (Can be used as 13th Step) Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 6 Smallest Capacitor Current 10mA CT Input Range 5mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 Modbus Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Comparison of CX and CX Plus Controllers Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    1 pcs in stock

    $959.00
    $1,131.62 inclGST

  • Last stock! ACXP12R-MB-D (BLR-CX Plus 12R-MB-D), CX-Plus Power Factor Regulator, 12/13 Step, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Modbus RTU Comms, Step Time Recording, Alarm Recording, RS485 Modbus, with Internal Data Logger

    ACXP12R-MB-D (BLR-CX Plus 12R-MB-D), CX-Plus Power Factor Regulator, 12/13 Step, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Modbus RTU Comms, Step Time Recording, Alarm Recording, RS485 Modbus, with Internal Data Logger

    1 pcs in stock

    ACXP12R-MB-D (BLR-CX Plus 12R-MB-D), CX-Plus Power Factor Regulator, 12/13 Step, 1 Phase Measurement, 3 Phase Control, 110-480V 50/60HZ, Modbus RTU Comms, Step Time Recording, Alarm Recording, RS485 Modbus, with Internal Data Logger Single CT Sensing Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 13 steps Measurement System - Automatic/Manual 90-550VAC Aux/Measurement Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number ACXP12R-MB-D (BLR-CX Plus 12R-MB-D) / 3ACXP12R-BEL-G-MB-D Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 90-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/10Amp Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan Alarm 1 x Relay as above (Can be used as 13th Step) Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 6 Smallest Capacitor Current 10mA CT Input Range 5mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 Modbus Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Comparison of CX and CX Plus Controllers Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    1 pcs in stock

    $959.00
    $1,131.62 inclGST

  • Last stock! BLR-Q(U)12R (3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ BLR-Q(U)12R (3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ

    BLR-Q(U)12R (3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ

    1 pcs in stock

    BLR-Q(U)12R (3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-Q(U)12R / 3ACM12R-BEL-O-QMB Function Reactive Power Correction & Power Quality Analyser Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    1 pcs in stock

    $1,989.00
    $2,347.02 inclGST

  • Last stock! BLR-Q(U)06R (3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ BLR-Q(U)06R (3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ

    BLR-Q(U)06R (3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ

    1 pcs in stock

    BLR-Q(U)06R (3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 6 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-Q(U)06R / 3ACM06R-BEL-O-QMB Function Reactive Power Correction & Power Quality Analyser Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 6 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    1 pcs in stock

    $1,789.00
    $2,111.02 inclGST

  • Last stock! UT927A, 92mmx25mm Coooling Fan, 230VAC, 13/11W, 50/60Hz Impedance Protected Ball Bearing Fan with terminals

    UT927A, 92mmx25mm Coooling Fan, 230VAC, 13/11W, 50/60Hz Impedance Protected Ball Bearing Fan with terminals

    1 pcs in stock

    UT927A, 92mmx25mm Coooling Fan, 230VAC, 13/11W, 50/60Hz Impedance Protected Ball Bearing Fan with terminals Not somemarks on propduct due to sittign in excess stock. Otherwise unused as new 

    1 pcs in stock

    $15.00
    $17.70 inclGST

  • Last stock! FA-119B-T6L, 119mmx25mm Cooling Fan, 230VAC, 12/10W, Impedance Protected Ball Bearing Fan

    FA-119B-T6L, 119mmx25mm Cooling Fan, 230VAC, 12/10W, Impedance Protected Ball Bearing Fan

    2 pcs in stock

    FA-119B-T6L, 119mmx25mm Cooling Fan, 230VAC, 12/10W, Impedance Protected Ball Bearing Fan Datasheet

    2 pcs in stock

    $25.00
    $29.50 inclGST

  • FGM6DC-630 320A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 320 Amp, 1500VDC FGM6DC-630 320A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 320 Amp, 1500VDC

    FGM6DC-630 320A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 320 Amp, 1500VDC

    8 pcs in stock

    Trent FGM6DC-630 320A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 320 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 2 Pole Disconnect 20kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-630 320A Functions 2 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 320 Amps @ 40 Deg C Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 1,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 20kA Approvals TUV, CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Dimensions W98xH310xD130mm Weight 6.6kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    8 pcs in stock

    $429.00
    $506.22 inclGST

  • TC-FGM6S-4P-160, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 160, 1 PC ONLY

    TC-FGM6S-4P-160, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 160, 1 PC ONLY

    12 pcs in stock

    Trent TC-FGM6S-4P-160, Terminal Cover for 4 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 160, 1 PC ONLY  Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-4P-160 Functions 4 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    12 pcs in stock

    $12.00
    $14.16 inclGST

  • TC-FGM6S-3P-250, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLY

    TC-FGM6S-3P-250, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLY

    16 pcs in stock

    Trent TC-FGM6S-3P-250, Terminal Cover for 3 Pole Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLY  Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : IP40 Terminal Cover UL94V0 Material Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number TC-FGM6S-3P-250 Functions 3 Pole MCCB Operating Temperature -25 to 50 Deg C Insulation Voltage 800V Weight 50g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    16 pcs in stock

    $12.00
    $14.16 inclGST

  • Last stock! FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    5 pcs in stock

    LEM FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SUI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    5 pcs in stock

    $429.00
    $506.22 inclGST

  • Last stock! FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    5 pcs in stock

    LEM FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 3000-SUI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 3000 Amp Measurement Range +/-9000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    5 pcs in stock

    $429.00
    $506.22 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account