Power Factor Correction Controllers

41 products

  • Last stock! BLR-Q(U)12R (3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ BLR-Q(U)12R (3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ

    BLR-Q(U)12R (3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ

    1 pcs in stock

    BLR-Q(U)12R (3ACM12R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 12 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-Q(U)12R / 3ACM12R-BEL-O-QMB Function Reactive Power Correction & Power Quality Analyser Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    1 pcs in stock

    $1,989.00
    $2,347.02 inclGST

  • Last stock! BLR-Q(U)06R DM (3ACM06R-BEL-O-DM), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, WITH BATTERY BACKUP, 3 Phase Control, 50-530V 50/60HZ BLR-Q(U)06R DM (3ACM06R-BEL-O-DM), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, WITH BATTERY BACKUP, 3 Phase Control, 50-530V 50/60HZ

    BLR-Q(U)06R DM (3ACM06R-BEL-O-DM), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, WITH BATTERY BACKUP, 3 Phase Control, 50-530V 50/60HZ

    1 pcs in stock

    BLR-Q(U)06R DM (3ACM06R-BEL-O-DM), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, WITH BATTERY BACKUP, 3 Phase Control, 50-530V 50/60HZ Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 6 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-Q(U)06R DM / 3ACM06R-BEL-O-DM Function Reactive Power Correction & Power Quality Analyser with battery backup Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional Battery Backup YES 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 6 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    1 pcs in stock

    $1,789.00
    $2,111.02 inclGST

  • Last stock! BLR-Q(U)06R (3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ BLR-Q(U)06R (3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ

    BLR-Q(U)06R (3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ

    1 pcs in stock

    BLR-Q(U)06R (3ACM06R-BEL-O-QMB), Power Factor Regulator & Power Quality Analyser, 6 Step, 1 Phase Measurement, Power Quality Alarms, 3 Phase Control, 50-530V 50/60HZ Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 6 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-Q(U)06R / 3ACM06R-BEL-O-QMB Function Reactive Power Correction & Power Quality Analyser Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 6 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    1 pcs in stock

    $1,789.00
    $2,111.02 inclGST

  • Last stock! BLR-CM12R3PHASE (3ACM06R-BEL-O 3PHASE), Power Factor Regulator, 12 Step, 3 Phase Measurement, 3 Phase or Single Phase Control of 3 phase Circuit, 50-530V 50/60HZ (OBSOLETE 2025) BLR-CM12R3PHASE (3ACM06R-BEL-O 3PHASE), Power Factor Regulator, 12 Step, 3 Phase Measurement, 3 Phase or Single Phase Control of 3 phase Circuit, 50-530V 50/60HZ (OBSOLETE 2025)

    BLR-CM12R3PHASE (3ACM06R-BEL-O 3PHASE), Power Factor Regulator, 12 Step, 3 Phase Measurement, 3 Phase or Single Phase Control of 3 phase Circuit, 50-530V 50/60HZ (OBSOLETE 2025)

    1 pcs in stock

    BLR-CM12R3PHASE (3ACM06R-BEL-O 3PHASE), Power Factor Regulator, 12 Step, 3 Phase Measurement, 3 Phase or Single Phase Control of 3 phase Circuit, 50-530V 50/60HZ (OBSOLETE 2025) Three CT Sensing 32nd Harmonic Measurement Load balancing Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-CM12R / 3ACM06R-BEL-O 3PHASE Function Reactive Power Correction / Load Balancing Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Included Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    1 pcs in stock

    $1,445.00
    $1,705.10 inclGST

  • BLR-CM12R-MB-D, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms & Datalogger (OBSOLETE 2025) BLR-CM12R-MB-D, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms & Datalogger (OBSOLETE 2025)

    BLR-CM12R-MB-D, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms & Datalogger (OBSOLETE 2025)

    Out of stock

    BLR-CM12R-MB-D, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms & Datalogger (OBSOLETE 2025) Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-CM12R-MB-D Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Included 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 Modbus RTU Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    Out of stock

    $1,775.00
    $2,094.50 inclGST

  • BLR-CM12R-MB, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025) BLR-CM12R-MB, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025)

    BLR-CM12R-MB, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025)

    Out of stock

    BLR-CM12R-MB, Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025) Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-CM12R-MB Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 Modbus RTU Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    Out of stock

    $1,549.75
    $1,828.71 inclGST

  • BLR-CM06R-MB (3ACM06R-BEL-O-MB), Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025) BLR-CM06R-MB (3ACM06R-BEL-O-MB), Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025)

    BLR-CM06R-MB (3ACM06R-BEL-O-MB), Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025)

    Out of stock

    BLR-CM06R-MB (3ACM06R-BEL-O-MB), Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, RS485 Modbus RTU Comms (OBSOLETE 2025) Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 6 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-CM06R-MB / 3ACM06R-BEL-O-MB Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 Modbus RTU Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    Out of stock

    $1,391.00
    $1,641.38 inclGST

  • BLR-CM06R (3ACM06R-BEL-O), Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ (OBSOLETE 2025) BLR-CM06R (3ACM06R-BEL-O), Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ (OBSOLETE 2025)

    BLR-CM06R (3ACM06R-BEL-O), Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ (OBSOLETE 2025)

    Out of stock

    BLR-CM06R (3ACM06R-BEL-O), Power Factor Regulator, 6 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ (OBSOLETE 2025) Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 6 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-CM06R / 3ACM06R-BEL-O Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    Out of stock

    $1,269.75
    $1,498.31 inclGST

  • Last stock! BLR-CM12R (3ACM12R-BEL-O), Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, (OBSOLETE 2025) BLR-CM12R (3ACM12R-BEL-O), Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, (OBSOLETE 2025)

    BLR-CM12R (3ACM12R-BEL-O), Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, (OBSOLETE 2025)

    4 pcs in stock

    BLR-CM12R (3ACM12R-BEL-O), Power Factor Regulator, 12 Step, 1 Phase Measurement, 3 Phase Control, 50-530V 50/60HZ, (OBSOLETE 2025) Single CT Sensing 32nd Harmonic Measurement Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.9 to 0.9 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 50-530VAC Measurement 100-132V / 207-253VAC (L-N) Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-CM12R / 3ACM12R-BEL-O Function Reactive Power Correction Nominal Voltage (Un) 50-530VAC Line to Line Supply Voltage 100-132V / 207-253VAC (L-N), 45-65Hz, max fuse 6A Relay Rating 250VAC/5Amp Static Output Rating (T Models) 8-48VDC / 100mA Internal 2MB Logger  Optional 3 x CT Measurement  Optional Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature/Fan/THD Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.90 IND - 0.90 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 15mA - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms Optional Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus user Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    4 pcs in stock

    $1,378.50
    $1,626.63 inclGST

  • Last stock! MBD, Communication Converter RS485 Modbus RTU to USB, USB Powered, For Beluk CX Plus Series Power Factor Controller to use Free software

    MBD, Communication Converter RS485 Modbus RTU to USB, USB Powered, For Beluk CX Plus Series Power Factor Controller to use Free software

    4 pcs in stock

    MBD, Communication Converter RS485 Modbus RTU to USB, USB Powered, For Beluk CX Plus Series Power Factor Controller to use Free software USB/RS485/Ethernet Comms as standard Modbus TCP/RTU Protocols 5-36VDC Supply Features : 1 RS485 Ports or 1 x Ethernet Port, 1 x USB service Port Free user config software  Specification Beluk Part Number MBD Functions RS485 Modbus RTU to USB Communication Converter Supply Voltage 5V USB Powered Protocols TCP/RTU/USB Communication Ports USB, RS485 RS485/RS232 Baud Rate 1200,2400,4800,9600,19200,38400,57600,115200 bit/s USB Baud Rate 115200 bit/s Isolation 3.5kV Weight 250g Factory Pack Qty 1 EU Directives EN61000, EN61010 Safety Protection Class II Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -20 →+70 °C   Datasheet User Manual

    4 pcs in stock

    $278.50
    $328.63 inclGST

  • Beluk BLR-CX14R, Power Factor Regulator, 14 Step, 110-480V 50/60HZ Beluk BLR-CX14R, Power Factor Regulator, 14 Step, 110-480V 50/60HZ

    Beluk BLR-CX14R, Power Factor Regulator, 14 Step, 110-480V 50/60HZ

    Out of stock

    Beluk BLR-CX14R, Power Factor Regulator, 14 Step, 110-480V 50/60HZ Single CT Sensing Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 14 steps Measurement System - Automatic/Manual 230VAC Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number Beluk BLR-CX14R Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 90-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/10Amp Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 14 Smallest Capacitor Current 10mA CT Input Range 0 - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms N/A Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Iskra Quick Setup Guide Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    Out of stock

    $825.00
    $973.50 inclGST

  • Beluk BLR-CX06R, Power Factor Regulator, 6 Step, 110-480V 50/60HZ Beluk BLR-CX06R, Power Factor Regulator, 6 Step, 110-480V 50/60HZ

    Beluk BLR-CX06R, Power Factor Regulator, 6 Step, 110-480V 50/60HZ

    7 pcs in stock

    Beluk Beluk BLR-CX06R, Power Factor Regulator, 6 Step, 110-480V 50/60HZ or Vishay Estamat PFC-6N), Electronicon PFR-X+ 06R, 6 Step, 110-480V 50/60HZ Single CT Sensing Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 6 steps Measurement System - Automatic/Manual 230VAC Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio   Specification Beluk Part Number BLR-CX06R Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 90-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/10Amp Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 6 Smallest Capacitor Current 10mA CT Input Range 0 - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms N/A Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus RS485 User Manual Iskra Quick Setup Guide Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)

    7 pcs in stock

    $569.00
    $671.42 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account