Motor Protection Breakers & Motor Start Relays

55 products

  • FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release

    59 pcs in stock

    Trent FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M08 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 2.3 - 4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    59 pcs in stock

    $62.00
    $73.16 inclGST

  • FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release

    59 pcs in stock

    Trent FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M10 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 4 - 6.3 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives  

    59 pcs in stock

    $62.00
    $73.16 inclGST

  • MST-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range FE-MS-25-10

    MST-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal Release Only

    10 pcs in stock

    Iskra Doo MST-25-10, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers anre a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-10 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 6 - 10 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    10 pcs in stock

    $89.75
    $105.91 inclGST

  • Last stock! MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage

    MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage

    5 pcs in stock

    Iskra Doo MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-A220-240 Functions Shunt Trip release for 3 Phase Motor Protection Switch Nominal Voltage 230VAC @ 50/60Hz Nominal Current Range 6 Amp RMS @400VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity N/A Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    5 pcs in stock

    $39.80
    $46.96 inclGST

  • 4CR-1-645, AC Motor Start Relay (Klixon), 4.55 Amp Max Pickup Current, 3.8 Amp Minimum Drop Out Current 4CR-1-645, AC Motor Start Relay (Klixon), 4.55 Amp Max Pickup Current, 3.8 Amp Minimum Drop Out Current

    4CR-1-645, AC Motor Start Relay (Klixon), 4.55 Amp Max Pickup Current, 3.8 Amp Minimum Drop Out Current

    74 pcs in stock

    Sensata 4CR-1-645, AC Motor Start Relay (Klixon), 4.55 Amp Max Pickup Current, 3.8 Amp Minimum Drop Out Current Klixon 4CR Current Type Motor starting relay is a compact, high capacity relay, designed for universal application to split phase and capacitor start, single phase motors with start-winding currents up to 25 Amperes. Features : Reliable Operation and long life Wide Range of Pickup and drop out ratings Start-winding current rating - 25 Amps Small size for installation in compact equipment Economical Specification Iskra Doo Part Number 4CR-1-645 Functions Splitphase Motor Start Relay Nominal Current Range 3.8 - 4.55 Amp RMS Weight 70g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes How to Test 4CR Relays - Blog

    74 pcs in stock

    $65.00
    $76.70 inclGST

  • 4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current 4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current

    4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current

    12 pcs in stock

    Sensata 4CR-1-770, AC Motor Start Relay, 25 Amp Max Pickup Current, 20.6 Amp Minimum Drop Out Current Klixon 4CR Current Type Motor starting relay is a compact, high capacity relay, designed for universal application to split phase and capacitor start, single phase motors with start-winding currents up to 25 Amperes. Features : Reliable Operation and long life Wide Range of Pickup and drop out ratings Start-winding current rating - 25 Amps Small size for installation in compact equipment Economical Specification Iskra Doo Part Number 4CR-1-770 Functions Splitphase Motor Start Relay Nominal Current Range 20.6 - 25 Amp RMS Weight 70g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Application Notes How to Test 4CR Relays - Blog

    12 pcs in stock

    $85.00
    $100.30 inclGST

  • FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release

    120 pcs in stock

    Trent FGV2-M21, Motor Protection Switch, 3 Phase, 690VAC, 17 - 23 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M21 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 17 - 23 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    120 pcs in stock

    $68.00
    $80.24 inclGST

  • FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp

    FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp

    Out of stock

    Trent FGV2-MAN20, Auxiliary Contact for FGV2 series Motor Protection Switch, 2x NO, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-MAN20 Functions Auxiliary Contact Nominal Voltage 230/400VAC @ 50/60Hz Configuration 1 x NO 1 x NC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $12.00
    $14.16 inclGST

  • FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp

    FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp

    233 pcs in stock

    Trent FGV2-MAN11, Auxiliary Contact for FGV2 series Motor Protection Switch, 1x NO, 1 x NC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-MAN11 Functions Auxiliary Contact Nominal Voltage 230/400VAC @ 50/60Hz Configuration 1 x NO 1 x NC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    233 pcs in stock

    $12.00
    $14.16 inclGST

  • FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp

    FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp

    200 pcs in stock

    Trent FGV2-M AU400, Shunt Trip Release for FGV2 series Motor Protection Switch, 385-415VAC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M AU400 Functions Shunt Trip/Voltage Release Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0-6 Amp (Ith) Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Release Voltage 385-415VAC Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    200 pcs in stock

    $12.00
    $14.16 inclGST

  • FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp

    FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp

    Out of stock

    Trent FGV2-M AU225, Shunt Trip Release for FGV2 series Motor Protection Switch, 220-240VAC, Ith = 6 Amp Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M AU225 Functions Shunt Trip/Voltage Release Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0-6 Amp (Ith) Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Release Voltage 220-240VAC Approvals CE Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    Out of stock

    $12.00
    $14.16 inclGST

  • FGV3-M80, Motor Protection Switch, 3 Phase, 690VAC, 56 - 80 Amp Setting Range, Thermal and Magnetic Release FGV3-M80, Motor Protection Switch, 3 Phase, 690VAC, 56 - 80 Amp Setting Range, Thermal and Magnetic Release

    FGV3-M80, Motor Protection Switch, 3 Phase, 690VAC, 56 - 80 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Trent FGV3-M80, Motor Protection Switch, 3 Phase, 690VAC, 56 - 80 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV3-M80 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 56 - 80 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $76.00
    $89.68 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account