LEM Price Group #19

15 products

  • FKPC-200-400 Rev 2 (FKPC-240-CE Rev 2), Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240 FKPC-200-400 Rev 2 (FKPC-240-CE Rev 2), Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240

    FKPC-200-400 Rev 2 (FKPC-240-CE Rev 2), Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240

    20 pcs in stock

    FastronFKPC-200-400 Rev 2, Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240, CE Approved, Previously FKPC-240-CE Rev 2 Rev 2: Supports Inputs: 4-20mA,0-10V, 0-5V or 10K POT Proportional Phase Control Input Suitable for SCR Blocks up to 3000 Amp Instantaneous turn-on output CE Approval (Pending) Can Replace Semikron Semi-PCM 2 SKPC200 for most applications. Please take care to connect 240VAC Aux Supply Seperately and connect the gate leads to cathode rather than anode  Specification Fastron part Number FKPC200-400 Rev 2 (Previously FKPC-240-CE Rev 2) (Possible Replacement to SKPC200-240) Switching Type Phase Angle (Random Crossing) Control Voltage 4-20mA,0-10V,0-5V,10K POT Proportional Input (Note the zero value is 0.20.3V to avoid noise to cause gate firing Load Current Based on SCR Stack Special Feature Single Phase Proportional Controller/Trigger Mounting Style Panel Mount Load Voltage Range 200-450VAC +10% Auxiliary Power Supply 200-450VAC +10% Termination Style Barrier Strip Screw Dimensions 105 x 90 x 40mm Certifications EMC EN 61000-6-3:2007+A1:2011, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A1:2019, EN IEC 61000-6-1:2019 Certifications LVD Low Voltage Directive 2014/35/EU, EN IEC 60947-1:2021 Unit Weight 400g Factory Pack Qty 20   Datasheet and User Manual User Manual FKPC wiring Half Controlled M505012F Crydom Bridge for up to 240VAC - 400VAC Load FKPC wiring Half Controlled SKCH28/16 Bridge for up to 240VAC - 400VAC Load FKPC AC Switch Wiring

    20 pcs in stock

    $325.00
    $383.50 inclGST

  • PCM 10-P/SP1, Pointsenz Railway Bipolar DC Current Sensor, 10 Amp, With 2M cable, Bipolar 4-20mA Output

    PCM 10-P/SP1, Pointsenz Railway Bipolar DC Current Sensor, 10 Amp, With 2M cable, Bipolar 4-20mA Output

    20 pcs in stock

    LEM PCM 10-P/SP1 Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected 2M flying leads Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 10-P/SP1 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 10 Amp Measuring Range +/- 20 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style Switchcraft EN3L4M connector with 2M Flying Leads Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    20 pcs in stock

    $696.00
    $821.28 inclGST

  • 50.34.02.549.0 (HTRS DIN Adaptor) 50.34.02.549.0 (HTRS DIN Adaptor)

    50.34.02.549.0 (HTRS DIN Adaptor)

    28 pcs in stock

    LEM 50.34.02.549.0 (HTRS DIN Adaptor)   Datasheet Product Datasheet Application Notes FAQ

    28 pcs in stock

    $4.90
    $5.78 inclGST

  • HTRS 10-SBI, Railway Split Core DC Current Sensor, 10 Amp, 4-20mA Output

    HTRS 10-SBI, Railway Split Core DC Current Sensor, 10 Amp, 4-20mA Output

    32 pcs in stock

    LEM HTRS 10-SBI, Railway Split Core DC Current Sensor, 10 Amp, 4-20mA Output Features Closed loop sensor using Hall Effect Din Rail or Panel Mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number HTRS 10-SBI Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø10mm Load Current (RMS + DC) 10 Amp Measuring Range +/- 20 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-30kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style Molex 436500300 Unit Weight 35g Factory Pack Qty 4 Datasheet Product Datasheet Application Notes FAQ

    32 pcs in stock

    $245.56
    $289.76 inclGST

  • PCM 10-P, Pointsenz Railway DC Current Sensor, 10 Amp, Bipolar 4-20mA Output

    PCM 10-P, Pointsenz Railway DC Current Sensor, 10 Amp, Bipolar 4-20mA Output

    10 pcs in stock

    LEM PCM 10-P Series Closed Loop DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 10-P Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 10 Amp Measuring Range +/- 20 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C (50°C Continuous) Accuracy 0.5% Termination Style Switchcraft EN3L4M connector Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    10 pcs in stock

    $775.00
    $914.50 inclGST

  • FKPC-200-400 Rev 3 (FKPC-240-CE Rev 3), Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240 FKPC-200-400 Rev 3 (FKPC-240-CE Rev 3), Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240

    FKPC-200-400 Rev 3 (FKPC-240-CE Rev 3), Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240

    Out of stock

    Fastron FKPC-200-400 Rev 3 (FKPC-240-CE Rev 3), Single Phase Voltage Control SCR Trigger Module, 4-20mA,0-10V,0-5V,5K POT Input, 200-450VAC, 240VAC Aux Supply, Can Replace Semikron Semi-PCM 2 SKPC200-240 Rev 2: Supports Inputs: 4-20mA,0-10V, 0-5V or 10K POT Proportional Phase Control Input Rev 3: As above and with added internal circuit protection to imporve reliability in noisy environments.  Suitable for SCR Blocks up to 3000 Amp Instantaneous turn-on output CE Approval (Pending) Can Replace Semikron Semi-PCM 2 SKPC200 for most applications. Please take care to connect 240VAC Aux Supply Seperately and connect the gate leads to cathode rather than anode . see full wirign detail in the datasheet Tab in this page Specification Fastron part Number FKPC200-400 Rev 3 (Previously FKPC-240-CE Rev 3) (Possible Replacement to SKPC200-240) Switching Type Phase Angle (Random Crossing) Control Voltage 4-20mA,0-10V,0-5V,10K POT Proportional Input (Note the zero value is 0.20.3V to avoid noise to cause gate firing Load Current Based on SCR Stack Special Feature Single Phase Proportional Controller/Trigger Mounting Style Panel Mount Load Voltage Range 200-450VAC +10% Auxiliary Power Supply 200-450VAC +10% Termination Style Barrier Strip Screw Dimensions 105 x 90 x 40mm Certifications EMC EN 61000-6-3:2007+A1:2011, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A1:2019, EN IEC 61000-6-1:2019 Certifications LVD Low Voltage Directive 2014/35/EU, EN IEC 60947-1:2021 Unit Weight 400g Factory Pack Qty 20   Datasheet and User Manual User Manual FKPC wiring Half Controlled M505012F Crydom Bridge for up to 240VAC - 400VAC Load FKPC wiring Half Controlled SKCH28/16 Bridge for up to 240VAC - 400VAC Load FKPC AC Switch Wiring

    Out of stock

    $325.00
    $383.50 inclGST

  • PCM 20-P/SP2, Pointsenz Railway Unipolar DC Current Sensor, 20 Amp, 4-20mA Unipolar Output

    PCM 20-P/SP2, Pointsenz Railway Unipolar DC Current Sensor, 20 Amp, 4-20mA Unipolar Output

    Out of stock

    LEM PCM 20-P/SP2, Pointsenz Railway Bipolar DC Current Sensor, 20 Amp, 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 20-P/SP2 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 20 Amp Measuring Range 0...20 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style TBC Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    Out of stock

    $753.30
    $888.89 inclGST

  • PCM 10-PR/SP1, Pointsenz Railway Bipolar DC Current Sensor, 10 Amp, Bipolar 4-20mA Output, With 0.25M cable

    PCM 10-PR/SP1, Pointsenz Railway Bipolar DC Current Sensor, 10 Amp, Bipolar 4-20mA Output, With 0.25M cable

    Out of stock

    LEM PCM 10-PR/SP1, Pointsenz Railway Bipolar DC Current Sensor, 10 Amp, With 0.25M cable, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected 2M flying leads Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 10-PR/SP1 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 10 Amp Measuring Range +/- 30 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 2% Termination Style Via a 4 core screened Unitronic Etherline H-Flex CAT 5, Lapp number 2170283 length of 0.25 m. Terminated by a male, miniature circular 4 pin connector with a shielding ring series 423. Binder number 99-5109-15-04 Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    Out of stock

    $757.55
    $893.91 inclGST

  • PCM 5-PR/SP2, Pointsenz Railway Bipolar DC Current Sensor, 5 Amp Input, Bipolar 4-20mA Output, With 2M cable

    PCM 5-PR/SP2, Pointsenz Railway Bipolar DC Current Sensor, 5 Amp Input, Bipolar 4-20mA Output, With 2M cable

    Out of stock

    LEM PCM 5-PR/SP2, Pointsenz Railway Bipolar DC Current Sensor, 5 Amp Input, Bipolar 4-20mA Output, With 2M cable Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected 2M flying leads Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 5-PR/SP2 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 5 Amp Measuring Range +/- 10 Amp Overload Capacity (Ampere Turns) 15000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style Switchcraft EN3L4M connector with 2M Flying Leads Unit Weight 120g Factory Pack Qty 4 Datasheet Product Datasheet Application Notes FAQ

    Out of stock

    $868.30
    $1,024.59 inclGST

  • Last stock! HTRS 50-SBI, Railway Split Core DC Current Sensor, 50 Amp, 4-20mA Output

    HTRS 50-SBI, Railway Split Core DC Current Sensor, 50 Amp, 4-20mA Output

    3 pcs in stock

    LEM HTRS 50-SBI, Railway Split Core DC Current Sensor, 50 Amp, 4-20mA Output Features Closed loop sensor using Hall Effect Din Rail or Panel Mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number HTRS 50-SBI Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø10mm Load Current (RMS + DC) 50 Amp Measuring Range +/- 100 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-30kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style Molex 436500300 Unit Weight 35g Factory Pack Qty 4 Datasheet Product Datasheet Application Notes FAQ

    3 pcs in stock

    $251.56
    $296.84 inclGST

  • HTRS 30-SBI, Railway Split Core DC Current Sensor, 30 Amp, 4-20mA Output

    HTRS 30-SBI, Railway Split Core DC Current Sensor, 30 Amp, 4-20mA Output

    33 pcs in stock

    LEM HTRS 30-SBI, Railway Split Core DC Current Sensor, 30 Amp, 4-20mA Output Features Closed loop sensor using Hall Effect Din Rail or Panel Mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number HTRS 30-SBI Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø10mm Load Current (RMS + DC) 30 Amp Measuring Range +/- 60 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-30kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style Molex 436500300 Unit Weight 35g Factory Pack Qty 4 Datasheet Product Datasheet Application Notes FAQ

    33 pcs in stock

    $245.56
    $289.76 inclGST

  • LEM International SA AC/DC Current Hall Effect Sensor PCM 30-P, Pointsenz Railway DC Current Sensor, 30 Amp, 4-20mA Output FE-PCM30-P

    PCM 30-P/SP2, Pointsenz Railway Bipolar DC Current Sensor, 30 Amp, Bipolar 4-20mA Output

    Out of stock

    LEM PCM 30-P/SP2 Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output Features Closed loop sensor using Hall Effect Panel mounting Split core design for easy installation Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67 Reverse polarity protected 3M screened cable connection Advantages Very good linearity Excellent accuracy Current overload capability No insertion losses. Non - contact measurement (does not need a safety case) Applications Railway equipment Points condition monitoring Signal light indication Battery supplied applications Uninterruptable Power Supplies (UPS). Specification LEM Part Number PCM 30-P/SP2 Technology Closed Loop Hall Effect ROHS Yes Supply Voltage 24V Aperture ø15.6mm Load Current (RMS + DC) 30 Amp Measuring Range +/- 60 Amp Overload Capacity (Ampere Turns) 30000 Amp Output 4-20mA Standards EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety) Bandwidth DC-1000Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C (55°C Continuous) Accuracy 0.5% Termination Style 4 Core Screened Cable 3M Unit Weight 120g Factory Pack Qty 4   Datasheet Product Datasheet Application Notes FAQ

    Out of stock

    $868.30
    $1,024.59 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account