LEM Price Group #18

22 products

  • HOP 300-SB O/L Split Core Hall Effect Current Sensor, 300 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    HOP 300-SB O/L Split Core Hall Effect Current Sensor, 300 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    10 pcs in stock

    LEM HOP 300-SB O/L Split Core Hall Effect Current Sensor, 300 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% AC/DC Hall Effect Sensor Features Bandwidth DC to 8kHz Open loop transducer using Hall effect Compact and versatile Busbar Mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 200 to 600 A in one package. Up to 900 A measurement range Applications Power supplies for TELECOM (monitoring and measurement) Electrical chemistry Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Chopper Battery supplied applications Specification LEM Part Number HOP 600-SB Technology Open Loop Hall Effect Aperture 12.5 x 41mm ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/-450 Amp Overload Rating Contact Us for Possible Replacement Output +/-4 V Isolation 3 kV Bandwidth DC-8 kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 70°C Accuracy 2% Termination Style Molex 5045-04A Unit Weight 110g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    10 pcs in stock

    $285.00
    $336.30 inclGST

  • Last stock! HOP 2000-SB O/L Split Core Hall Effect Current Sensor, 2000 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    HOP 2000-SB O/L Split Core Hall Effect Current Sensor, 2000 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    5 pcs in stock

    LEM HOP 2000-SB O/L Split Core Hall Effect Current Sensor, 2000 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 10kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical or Busbar Mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 500 to 2500 A in one package. Up to 3000 A measurement range Applications Power supplies for TELECOM (monitoring and measurement) Electrical chemistry Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Chopper Battery supplied applications Specification LEM Part Number HOP 2000-SB Technology Open Loop Hall Effect Aperture 104 x 40mm Square ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/-3000 Amp Overload Rating Contact Us for Possible Replacement Output +/-4 V Isolation 3 kV Bandwidth DC-10 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 70°C Accuracy 2% Termination Style Molex 5045-04A Unit Weight 590g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    5 pcs in stock

    $799.00
    $942.82 inclGST

  • HOP 200-SB O/L Split Core Hall Effect Current Sensor, 200 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    HOP 200-SB O/L Split Core Hall Effect Current Sensor, 200 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    Out of stock

    LEM HOP 200-SB O/L Split Core Hall Effect Current Sensor, 200 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% AC/DC Hall Effect Sensor Features Bandwidth DC to 8kHz Open loop transducer using Hall effect Compact and versatile Busbar Mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 200 to 600 A in one package. Up to 900 A measurement range Applications Power supplies for TELECOM (monitoring and measurement) Electrical chemistry Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Chopper Battery supplied applications Specification LEM Part Number HOP 200-SB Technology Open Loop Hall Effect Aperture 12.5 x 41mm ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/-300 Amp Overload Rating Contact Us for Possible Replacement Output +/-4 V Isolation 3 kV Bandwidth DC-8 kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 70°C Accuracy 2% Termination Style Molex 5045-04A Unit Weight 110g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $285.00
    $336.30 inclGST

  • HOP 1500-SB O/L Split Core Hall Effect Current Sensor, 1500 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    HOP 1500-SB O/L Split Core Hall Effect Current Sensor, 1500 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    22 pcs in stock

    LEM HOP 1500-SB O/L Split Core Hall Effect Current Sensor, 1500 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 10kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical or Busbar Mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 500 to 2000 A in one package. Up to 3000 A measurement range Applications Power supplies for TELECOM (monitoring and measurement) Electrical chemistry Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Chopper Battery supplied applications Specification LEM Part Number HOP 1500-SB Technology Open Loop Hall Effect Aperture 104 x 40mm Square ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 1500 Amp Measurement Range +/-3000 Amp Overload Rating Contact Us for Possible Replacement Output +/-4 V Isolation 3 kV Bandwidth DC-10 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 70°C Accuracy 2% Termination Style Molex 5045-04A Unit Weight 590g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    22 pcs in stock

    $699.00
    $824.82 inclGST

  • Last stock! HOP 1000-SB O/L Split Core Hall Effect Current Sensor, 500 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    HOP 1000-SB O/L Split Core Hall Effect Current Sensor, 500 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2%

    5 pcs in stock

    LEM HOP 1000-SB O/L Split Core Hall Effect Current Sensor, 500 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 10kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical or Busbar Mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 500 to 2000 A in one package. Up to 3000 A measurement range Applications Power supplies for TELECOM (monitoring and measurement) Electrical chemistry Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Chopper Battery supplied applications Specification LEM Part Number HOP 1000-SB Technology Open Loop Hall Effect Aperture 104 x 40mm Square ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-2000 Amp Overload Rating Contact Us for Possible Replacement Output +/-4 V Isolation 3 kV Bandwidth DC-10 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 70°C Accuracy 2% Termination Style Molex 5045-04A Unit Weight 590g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    5 pcs in stock

    $659.70
    $778.45 inclGST

  • LF 205-S/SP6 C/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 15.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%

    LF 205-S/SP6 C/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 15.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%

    Out of stock

    LEM LF 205-S/SP6 C/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 15.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5% Features Bipolar and insulated current measurement up tp 420 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 205-S/SP6 Technology Closed Loop Hall Effect Aperture ø15.5mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 420 Amp Output 100 mA Isolation 3.5 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Molex 6410 Unit Weight 78g Factory Pack Quantity 60   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $217.40
    $256.53 inclGST

  • LF 306-S C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 25.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.4%

    LF 306-S C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 25.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.4%

    Out of stock

    LEM LF 306-S Series Closed Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 306-S Technology Closed Loop Hall Effect Aperture ø25.5mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 15 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/- 500 Amp Output 150 mA Isolation 3.8 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style Molex 5054-03/AG Unit Weight 60g Factory Pack Quantity 60 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $177.10
    $208.98 inclGST

  • LF 305-S C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 20.1mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%

    LF 305-S C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 20.1mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%

    Out of stock

    LEM LF 305-S Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 305-S Technology Closed Loop Hall Effect Aperture ø20.1mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 20 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/- 500 Amp Output 150 mA Isolation 3.8 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Molex 5054-03/AG Unit Weight 95g Factory Pack Quantity 60 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $121.90
    $143.84 inclGST

  • LF 210-S C/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 15.59mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.2%

    LF 210-S C/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 15.59mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.2%

    11 pcs in stock

    LEM LF 210-S Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 420 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 1000 A in one package. Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 210-S Technology Closed Loop Hall Effect Aperture ø15.59mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 420 Amp Output 100 mA Isolation 3.5 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.2% Termination Style Molex 6410 Unit Weight 75g Factory Pack Quantity 60 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    11 pcs in stock

    $95.26
    $112.41 inclGST

  • LF 205-S C/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 15.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%

    LF 205-S C/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 15.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%

    Out of stock

    LEM LF 205-S C/L Hall Effect Current Sensor, 200 Amp, 100mA Output, 15.5mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5% Features Bipolar and insulated current measurement up tp 420 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 205-S Technology Closed Loop Hall Effect Aperture ø15.5mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 420 Amp Output 100 mA Isolation 3.5 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Molex 6410 Unit Weight 78g Factory Pack Quantity 60   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $129.00
    $152.22 inclGST

Login

Forgot your password?

Don't have an account yet?