LEM Hall Effect Voltage Sensors Panel Mount

87 products

  • DVL 2000/SP5 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables

    DVL 2000/SP5 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 2000/SP5 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Input and output cables Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000/SP5 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Input and output cables Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $689.00
    $813.02 inclGST

  • DVL 2000/SP1 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000333181

    DVL 2000/SP1 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000333181

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 2000/SP1 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000333181 Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 SMS6GE6 Burndy connector output, DTR0000333181 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000/SP1 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style SMS6GE6 Burndy connector output, DTR0000333181 Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $644.00
    $759.92 inclGST

  • DVL 1500/SP7 Digital Voltage Transducer, Vpn = 1500V, 10V output, +/-15...24VDC powered, 8.5kV Isolation, Output Connections M5 Inserts

    DVL 1500/SP7 Digital Voltage Transducer, Vpn = 1500V, 10V output, +/-15...24VDC powered, 8.5kV Isolation, Output Connections M5 Inserts

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 1500/SP7 Digital Voltage Transducer, Vpn = 1500V, 10V output, +/-15...24VDC powered, 8.5kV Isolation, Output Connections M5 Inserts Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Output Connections M5 Inserts Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1500/SP7 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1500V Measurement Range +/- 2250V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Output Connections M5 Inserts Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $669.00
    $789.42 inclGST

  • DVL 150 Digital Voltage Transducer, Vpn = 150V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    DVL 150 Digital Voltage Transducer, Vpn = 150V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    12 pcs in stock

    LEM DVL 150 Digital Voltage Transducer, Vpn = 150V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 150 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 150V Measurement Range +/- 225V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    12 pcs in stock

    $551.00
    $650.18 inclGST

  • DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 125 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 125V Measurement Range +/- 187.5V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $551.00
    $650.18 inclGST

  • DVL 1000/SP8 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Output cables

    DVL 1000/SP8 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Output cables

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 1000/SP8 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Output cables Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1000/SP8 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Output cables Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $689.00
    $813.02 inclGST

  • DVL 1000/SP7 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables

    DVL 1000/SP7 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 1000/SP7 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Input and output cables Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Input and output cables Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1000/SP7 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Input and output cables Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $649.00
    $765.82 inclGST

  • DVL 1000/SP5 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Threaded inserts output, Short input studs

    DVL 1000/SP5 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Threaded inserts output, Short input studs

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 1000/SP5 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, Threaded inserts output, Short input studs Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Threaded inserts output, Short input studs Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1000/SP5 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Threaded inserts output, Short input studs Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $565.00
    $666.70 inclGST

  • DVL 1000/SP1 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000306545

    DVL 1000/SP1 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000306545

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM DVL 1000/SP1 Digital Voltage Transducer, Vpn = 1000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000306545 Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 SMS6GE6 Burndy connector output, DTR0000306545 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1000/SP1 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style SMS6GE6 Burndy connector output, DTR0000306545 Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $596.20
    $703.52 inclGST

  • LV100, C/L Voltage Transducer, 10mA Primary, +/-15VDC Aux, 50mA Output

    LV100, C/L Voltage Transducer, 10mA Primary, +/-15VDC Aux, 50mA Output

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    LV100, C/L Voltage Transducer, 10mA Primary, +/-15VDC Aux, 50mA Output Features Used for Voltage Transducer Design Current input and output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0   Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption   Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications   Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010   Specification LEM Part Number LV 100 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary Nominal Current 10mA Measurement Range +/- 20 mAmp Output 50 mA Isolation 6 kV Response time 20 - 100uS Mounting Style Panel Mount Operating Temperature Range 0°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 460g Factory Pack Quantity 6   Datasheet Product Datasheet

    Out of stock , More available in 10-12 Weeks

    Free Aus Post Shipping for $300 Spend

    $549.60
    $648.53 inclGST

  • LV 100-500, C/L Voltage Transducer, 500V, +/-15VDC Aux, 50mA Output

    LV 100-500, C/L Voltage Transducer, 500V, +/-15VDC Aux, 50mA Output

    Out of stock , More available in 6-8 Weeks

    Free Aus Post Shipping for $300 Spend

    LEM LV 100-500 C/L Voltage Transducer, 500V, +/-15VDC Aux, 50mA Output Features Bipolar and insulated voltage measurement up tp 750VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100-500 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary RMS Voltage 500V Measurement Range +/- 750 V Output 50 mA Isolation 9 kV Response 190uS Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet

    Out of stock , More available in 6-8 Weeks

    Free Aus Post Shipping for $300 Spend

    $879.30
    $1,037.57 inclGST

  • DVL 1500, Digital Voltage Transducer, 1500V, +/-15...24VDC, 50mA output, 8.5kV Isolation

    DVL 1500, Digital Voltage Transducer, 1500V, +/-15...24VDC, 50mA output, 8.5kV Isolation

    12 pcs in stock

    LEM DVL 1500, Digital Voltage Transducer, 1500V, +/-15...24VDC, 50mA output, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1500 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1500V Measurement Range +/- 2250V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    12 pcs in stock

    $551.00
    $650.18 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account