LEM DK 300 B420, Split Core Hall Effect DC Current Transducer, Multirange 150, 225, 300A DC, 4-20mA unipolar output, 20-50VDC supply
Compact and versatile Split Core DC current sensor, selectable 150, 225, 300 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V
Features
Split Core
DC Unipolar Measurement
0-10V Voltage output
Busbar or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 21.7mm sqr
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
DK 300 B420
Technology
DC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
20-20VDC
Nominal Current (RMS + DC)
150,225,300 Amp Selectable
Response Time
< 100ms
Output
4-20mA Analogue
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
2%
Termination Style
2 x UNC8 Cylindric Head
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
BH-300-2-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-300 Amp DC, 4-20mA Bipolar Output
Features
⌀31mm Aperture
Split Core
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-300-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-300 Amp DC
Response Time
< 200mS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-200-2-24, Split Core Hall Effect DC Current Transducer, +/-200 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-200 Amp DC, 4-20mA Bipolar Output
Features
⌀31mm Aperture
Split Core
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-200-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-200 Amp DC
Response Time
< 200mS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-100-2-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/100 Amp DC, 4-20mA Bipolar Output
Features
⌀31mm Aperture
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-300-1-24, Split Core Hall Effect DC Current Transducer, +/-300 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-300 Amp DC, Bipolar 0-10V, or Bipolar +/-10VDC Analogue
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-300-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-300 Amp DC
Response Time
< 200mS
Output
Bipolar 0-10V, or Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-200-1-24, Split Core Hall Effect DC Current Transducer, +/-200 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-200 Amp DC, Bipolar 0-10V, or Bipolar +/-10VDC Analogue
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-200-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/- 200 Amp DC
Response Time
< 200mS
Output
Bipolar 0-10V, or Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-100-1-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-100 Amp DC, +/-10VDC Bipolar or 0-10V Bipolar Analogue Output
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 0-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-50-2-24, Split Core Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-50 Amp DC, 4-20mA Bipolar Output
Features
⌀31mm Aperture
Split Core
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-50-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-50 Amp DC
Response Time
< 200mS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-50-1-24, Split Core Hall Effect DC Current Transducer, +/-50 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-50 Amp DC, +/-10VDC Bipolar or 0-10V Bipolar Analogue Output
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-50-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-50 Amp DC
Response Time
< 200mS
Output
Bipolar 0-10V, or Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
DC-0-300-420-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA Unipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20 mA Unipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-300-420-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-300 Amp
Response Time
< 1uS
Output
Unipolar 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
DC-0-50-420-1.0, Hall Effect DC Current Transducer, 0-50 Amp DC, 4-20mA Unipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-50 Amp DC, 4-20 mA Unipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-50-420-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-50 Amp
Response Time
< 1uS
Output
Unipolar 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
DC-0-100-420-1.0, Hall Effect DC Current Transducer, 0-100 Amp DC, 4-20mA Unipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-100 Amp DC, 4-20 mA Unipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-100-420-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-100 Amp
Response Time
< 1uS
Output
Unipolar 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet