Wi LEM EMN - W2 Single Phase 20 Amp Wireless CT
Features
Wide range of electrical parameters measurement
Wireless communication on license free 2.4 GHz
Class 1 accuracy active energy.
Advantages
Fast & easy mounting:
Wireless communication
Split core CT
Self powered from voltage line.
Compact
Gateway interface : RS 232/485 Modbus RTU
Applications
Energy sub-metering
Network condition monitoring
Energy audit & diagnostic Building energy management.
Ideal for retrofit applications.
Datasheet
Product Datasheet
Specification
This module is working with the mesh gate MG-5424.
Electrical data
IPN
Primary nominal current (A) Types
5 EMN 5 W2
20 EMN 20 W2
50 EMN 50 W2
100 EMN 100 W2
IP
Primary current measuring range (of IPN)
120
%
VP
Primary voltage measuring range (neutral/phase)1)
90 .. 265
Vrms
Permanent overload voltage (neutral/phase)
276
Vrms
f
Frequency
50/60
Hz
S
Output signal : radio frequency communication2) see MG-5424 datasheet
Power supply Line powered between N-L1 inputs
Power consumption Max 2 W
Measurement Values
Configurable reading interval : 5 .. 30 mn
Internal base values
Cummulated values
Av
Min
Max
Current (A)
X
Voltage (V)
X
Active Energy (kWh)
X
X
Reactive Energy (kVARh)
X
X
Apparent Energy (kVA)
X
X
Frequency
Wi LEM EMN - W2 Single Phase 100 Amp Wireless CT
Features
Wide range of electrical parameters measurement
Wireless communication on license free 2.4 GHz
Class 1 accuracy active energy.
Advantages
Fast & easy mounting:
Wireless communication
Split core CT
Self powered from voltage line.
Compact
Gateway interface : RS 232/485 Modbus RTU
Applications
Energy sub-metering
Network condition monitoring
Energy audit & diagnostic Building energy management.
Ideal for retrofit applications.
Datasheet
Product Datasheet
Specification
This module is working with the mesh gate MG-5424.
Electrical data
IPN
Primary nominal current (A) Types
5 EMN 5 W2
20 EMN 20 W2
50 EMN 50 W2
100 EMN 100 W2
IP
Primary current measuring range (of IPN)
120
%
VP
Primary voltage measuring range (neutral/phase)1)
90 .. 265
Vrms
Permanent overload voltage (neutral/phase)
276
Vrms
f
Frequency
50/60
Hz
S
Output signal : radio frequency communication2) see MG-5424 datasheet
Power supply Line powered between N-L1 inputs
Power consumption Max 2 W
Measurement Values
Configurable reading interval : 5 .. 30 mn
Internal base values
Cummulated values
Av
Min
Max
Current (A)
X
Voltage (V)
X
Active Energy (kWh)
X
X
Reactive Energy (kVARh)
X
X
Apparent Energy (kVA)
X
X
Frequency
LEM DVL 1500, Digital Voltage Transducer, 1500V, +/-15...24VDC, 50mA output, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Digital Transducer (ASIC based)
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 1500
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 1500V
Measurement Range
+/- 2250V
Output
50 mA @Vpn
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM DVL Series Closed Loop AC/DC Digital Voltage Transducer 1000V Input, 50mA output, +/- 15V…24VDC, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Digital Transducer (ASIC based)
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 1000
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 1000V
Measurement Range
+/- 1500V
Output
50 mA @Vpn
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM DHR 400 C420, Hall Effect Current Sensor, 400Amp , True RMS 4-20mA output
Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz
Features
VFD and SCR waveforms current measurement
True RMS output
4-20mA current output
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ?32mm
High isolation between primary and secondary circuits
Easy installation
Applications
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement
-Application Domain
Energy and Automation
Specification
LEM Part Number
DHR 400 C420
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
20 - 50V
Load Current (RMS + DC)
400 Amp
Output
4-20mA
Isolation
4kV (AC, 50Hz, 1 min)
Bandwidth
20-6000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
Level 3
Termination Style
SFKC 2.5/4-ST-5.08-RF(Phoenix Contact)
Unit Weight
260g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM DHR 100 C420, Hall Effect Current Sensor, 100Amp RMS, 4-20mA output
Compact and versatile transducer, 100Amp AC and DC, True RMS with signal conditioning. 4-20 mA output, Bandwidth: DC 20..6000 Hz
Features
VFD and SCR waveforms current measurement
True RMS output
4-20mA current output
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ?32mm
High isolation between primary and secondary circuits
Easy installation
Applications
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement
-Application Domain
Energy and Automation
Specification
LEM Part Number
DHR 100 C420
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
20 - 50V
Load Current (RMS + DC)
100 Amp
Output
4-20mA
Isolation
4kV (AC, 50Hz, 1 min)
Bandwidth
20-6000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
Level 3
Termination Style
SFKC 2.5/4-ST-5.08-RF(Phoenix Contact)
Unit Weight
260g
Factory Pack Qty
6
Datasheet
Product Datasheet
DH 800 B420L B Current Transducer, 800Amp Bipolar, 4-20mA output, 24V loop powered
Product Datasheet
, Obsolete - No replacement in single package. Contact us for a solution
CV 3-200/SP5 Voltage Transducer Flux Gate, Vpn = 140V RMS, 10V output, +/- 15/24VDC supply, 2.5kV Isolation
Features
Bandwidth DC to 700kHz
Closed loop transducer using Flux Gate
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
High Frequency Drives
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
CV 3-200/SP5
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 140V
Measurement Range
+/- 200V
Output
10V @Vp(max)
Isolation
2.5 kV
Bandwidth
DC-700 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 75°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
650g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
CTSR 0.6-P, C/L Hall Effect Earth Leakage Current Sensor, 600mA
Features
DC & AC earth leakage current transducer using a flux-gate principle
PCB mounting
±15V power supply
±5V output @ IPN
Isolated plastic case recognized
according to UL94-V0.
Advantages
Small size
Wide Aperture
Bandwidth : DC and 3.5 kHz
Response time better than 50 ms
Cost effective, compact alternative to classical RCDs (Residual Current Device)
Applications
Earth leakage detection in transformerless solar inverters
1st human contact protection of PV arrays
Failure detection in power sources Symmetrical fault detection (e.g. after motor inverter)
Current leakage detection in stacked DC sources
Single phase or three phase differential current measurement up to ±30A per wire (DC or AC)
Application Domains
Industrial
Specification
LEM Part Number
CTSR 0.6-P
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
+/-15VDC
Load Current (RMS + DC)
600mA
Output
5V Analogue
Isolation
5.4kV
Bandwidth
DC-3.5kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Aperture
ø 20.1mm
Unit Weight
28g
Factory Pack Qty
10
Datasheet
Product Datasheet
CT 0.4-P, C/L Hall Effect Earth Leakage Current Sensor, 400mA
Features
DC & AC earth leakage current transducer using a flux-gate principle
PCB mounting
±15V power supply
±5V output @ IPN
Isolated plastic case recognized
according to UL94-V0.
Advantages
Small size
Bandwidth : DC and 40 up to 7..18 kHz
Response time better than 60 ms
Cost effective, compact alternative to classical RCDs (Residual Current Device)
Applications
Earth leakage detection in transformerless solar inverters
1st human contact protection of PV arrays
Failure detection in power sources Symmetrical fault detection (e.g. after motor inverter)
Current leakage detection in stacked DC sources
Single phase or three phase differential current measurement up to ±30A per wire (DC or AC)
Application Domains
Industrial
Specification
LEM Part Number
CT 0.4-P
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
+/-15VDC
Load Current (RMS + DC)
400 mAmp
Output
5V Analogue
Isolation
2.5kV
Bandwidth
DC-7kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 125°C
Accuracy
1%
Aperture
ø 11mm
Unit Weight
10g
Factory Pack Qty
10
Datasheet
Product Datasheet
Phasing out - See CTSR Series for new 5VDC supply design
LEM CKSR 6-NP KIT 3P Series Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
4.3kV Isolation
Frequency bandwidth 300kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for PCB mounting
Advantages
CKSR footprint compatible
Very good dv/dt immunity
Low foot-print
Low offset drift
Reference pin with two modes REF IN and REF OUT
Extended measuring range for unipolar measurement.
High creepage / clearance distances
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Solar Inverter
Standards
EN 50178: 1997
UL 508: 2004
IEC 61010-1: 2010 (safety)
Application Domain
Industrial
Specification
LEM Part Number
CKSR 6-NP Sample Kit 3 P
Technology
Closed Loop Hall Effect
Aperture
None
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
6 Amp
Measurement Range
+/-20 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.8%
Termination Style
PCB
Unit Weight
9g
Factory Packaging
3
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Alternatives
LKSR 6-NP