LEM LV 100-1500 C/L Voltage Transducer, 1500V, +/-15VDC Aux, 50mA Output
Features
Bipolar and insulated voltage measurement up tp 2250VAC/DC
Current output
Closed loop (compensated) voltage transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Low power consumption
Applications
Railway Equipment
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Traction
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LV 100-1500
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/- 15 VDC Bipolar, Isolated
Primary RMS Voltage
1500V
Measurement Range
+/- 2250 V
Output
50 mA
Isolation
9 kV
Response Time
120uS
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 70°C
Accuracy
0.7%
Termination Style
Faston 45° 6.3 x 0.8mm and M5 threaded studs
Unit Weight
750g
Factory Pack Quantity
6
Datasheet
Product Datasheet
LEM LTSR 25-NP Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
4.3kV Isolation
Frequency bandwidth 200kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for PCB mounting
Vref IN Vref OUT
Multirange through PCB rounting
Advantages
LXSR footprint compatible
Excellent accuracy
Zero insertion losses
Very good linearity
Very good dv/dt immunity
High immunity to external intereference
Current overload capability
Optimised response time
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Standards
EN 50178: 1997
UL 508: 2013
IEC 61010-1(safety)
Application Domain
Industrial
Specification
LEM Part Number
LTSR 25-NP
Technology
Closed Loop Multirange Hall Effect
Aperture
ø3.2mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
25 Amp
Measurement Range
+/-80 Amp
Output
2.5 Vref
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.2%
Termination Style
PCB
Unit Weight
9g
Factory Packaging
3
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Alternatives
LXSR 25-NPS
LEM LTS 6-NP Closed Loop AC/DC Hall Effect Sensor
Features
Closed loop current transducer
Voltage output
3kV Isolation
Frequency bandwidth 200kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for PCB mounting
Vref IN Vref OUT
Advantages
LXSR footprint compatible
Excellent accuracy
Zero insertion losses
Very good linearity
Very good dv/dt immunity
High immunity to external intereference
Current overload capability
Optimised response time
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Standards
EN 50178: 1997
UL 508: 2013
IEC 61010-1(safety)
Application Domain
Industrial
Specification
LEM Part Number
LTS 6-NP
Technology
Closed Loop Hall Effect
Aperture
ø3.2mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
6 Amp
Measurement Range
+/-19.2 Amp
Output
2.5 Vref
Isolation
3 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.2%
Termination Style
PCB
Unit Weight
10g
Factory Packaging
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Alternatives
LXS 6-NP
LEM LT 4000-S, C/L Hall Effect current transducer, Ipn = 4000 Amp, Isn = 800mA, +/-15VDC Supply
Features
Bipolar and insulated current measurement up tp 6000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 4000-S
Technology
Closed Loop Hall Effect
Aperture
102mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
4000 Amp
Measurement Range
+/- 6000 Amp
Output
800 mA
Isolation
6 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.5%
Termination Style
M5 threaded studs
Unit Weight
12.1kg
Factory Pack Quantity
1
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LT 1005-S Open Loop AC/DC Hall Effect Sensor
Features
Bipolar and insulated current measurement up tp 2000 Amp
Current output
Bandwidth DC to 150kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 1005-S
Technology
Closed Loop Hall Effect
Aperture
ø40.5mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/- 2000 Amp
Output
200 mA
Isolation
6 kV
Bandwidth
DC-150 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.4%
Termination Style
M4 theaded studs
Unit Weight
850g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LF 2005-S, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply
Features
Bipolar and insulated current measurement up tp 3000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LF 2005-S
Technology
Closed Loop Hall Effect
Aperture
ø60.5mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
2000 Amp
Measurement Range
+/- 3000 Amp
Output
400 mA
Isolation
6 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.3%
Termination Style
Molex 6410
Unit Weight
1.5kg
Factory Pack Quantity
9
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LAH 25-NP, Multi Range C/L Current Sensor, Multi Range 25 Amp, 25mA Out, PCB Mount, +/-12..15V, X = 0.25% PCB Mount
Features
Bandwidth DC to 200kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
PCB Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LAH 25-NP
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
8,12,25 Amp Multirange through pin selection
Measurement Range
+/-55 Amp
Output
25 mA
Isolation
5 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.3%
Termination Style
Through Hole PCB
Unit Weight
20g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LA 55-P Series Closed Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 200kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LA55-P
Technology
Closed Loop Hall Effect
Aperture
13.5 x 10mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
50 Amp
Measurement Range
+/-70 Amp
Output
50 mA
Isolation
2.5 kV
Bandwidth
DC-200 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.65%
Termination Style
Through Hole PCB
Unit Weight
18g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LA 305-S Closed Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 100kHz
Closed loop transducer using Hall effect
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LA305-S
Technology
Closed Loop Hall Effect
Aperture
25.5 x 25.5mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
300 Amp
Measurement Range
+/-500 Amp
Output
150mA
Isolation
6 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.65%
Termination Style
Molex series 70543-0003
Unit Weight
95g
Factory Pack Quantity
60
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LA 25-NP/SP13, C/L Hall Effect Current Sensor, Multi Range 0.5 Amp, 25mA Output, PCB Mount, No Aperture
Features
Bandwidth DC to 150kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LA25-NP/SP13
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
0.5 Amp
Measurement Range
+/-0.72 Amp
Output
25 mA
Isolation
2.5 kV
Bandwidth
DC-150 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.5%
Termination Style
Through Hole PCB
Unit Weight
22g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LA 25-NP, C/L Hall Effect Current Sensor, Multi Range 25,12,8,6,5 Amp, 25mA Output, PCB Mount, No Aperture
Features
Bandwidth DC to 150kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
PCB Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LA25-NP
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
5,6,8,12,25 Amp Multirange through pin selection
Measurement Range
+/-36 Amp
Output
25 mA
Isolation
2.5 kV
Bandwidth
DC-150 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
0.5%
Termination Style
Through Hole PCB
Unit Weight
22g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LA 205-S Closed Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 100kHz
Closed loop transducer using Hall effect
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LA205-S
Technology
Closed Loop Hall Effect
Aperture
18 x 23mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-300 Amp
Output
100mA
Isolation
3.25 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.8%
Termination Style
Molex series 5046 4 pins
Unit Weight
110g
Factory Pack Quantity
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition