LEM Products

823 products

  • Last stock! ITN 900-S ULTRASTAB, C/L Hall Effect Sensor, High Precision, +/- 900 Amp DC, or 636 Amp AC RMS

    ITN 900-S ULTRASTAB, C/L Hall Effect Sensor, High Precision, +/- 900 Amp DC, or 636 Amp AC RMS

    2 pcs in stock

    ITN 900-S ULTRASTAB, C/L Hall Effect Sensor, Extremely High Precision, +/- 900 Amp DC, or 636 Amp AC RMS Measurement. 9-Pin D-Sub Interface. 30mm Round Aperture, +/-15VDC Supply Datasheet Product Datasheet

    2 pcs in stock

    $3,194.00
    $3,768.92 inclGST

  • DHR 1000 C420, Hall Effect Current Sensor, 1000Amp , True RMS 4-20mA output

    DHR 1000 C420, Hall Effect Current Sensor, 1000Amp , True RMS 4-20mA output

    7 pcs in stock

    LEM DHR 1000 C420, Hall Effect Current Sensor, 1000Amp , True RMS 4-20mA output Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 1000 C420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 1000 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6   Datasheet Product Datasheet

    7 pcs in stock

    $394.00
    $464.92 inclGST

  • ITZ 16000-SB, Laboratory Hall Effect Current Sensor, High Precision X = 0.0065%, 100-240VAC Power Supply

    ITZ 16000-SB, Laboratory Hall Effect Current Sensor, High Precision X = 0.0065%, 100-240VAC Power Supply

    Out of stock

    ITZ 16000-SB, Laboratory Hall Effect Current Sensor, High Precision X = 0.0065%, 100-240VAC Power Supply Datasheet Product Datasheet

    Out of stock

    $59,345.10
    $70,027.22 inclGST

  • HAZ 20000-SB, Hall Effect Current Transducer, 20000A, +/-10V Instant Output, +/-15V supply-AC/DC Current Hall Effect Sensor-LEM International SA-Fastron Electronics Store HAZ 20000-SB, Hall Effect Current Transducer, 20000A, +/-10V Instant Output, +/-15V supply

    HAZ 20000-SB, Hall Effect Current Transducer, 20000A, +/-10V Instant Output, +/-15V supply

    Out of stock

    LEM HAZ 20000-SB, Hall Effect Current Transducer, 20000A, +/-10V Instant Output, +/-15V supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide current ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 20000-SB Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 20000 Amp Overload Rating 30000 At Output +/-10 V Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $4,481.00
    $5,287.58 inclGST

  • Last stock! LV 25P/SP5, C/L Hall Effect Voltage Sensor 10mA@10-500V, 25mA Output

    LV 25P/SP5, C/L Hall Effect Voltage Sensor 10mA@10-500V, 25mA Output

    4 pcs in stock

    LEM LV 25P/SP5, C/L Hall Effect Voltage Sensor 10mA@10-500V, 25mA Output Features Bandwidth DC to 25kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LV 25-P/SP5 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Primary Nominal Current (RMS + DC) 10 mA Measurement Range 10 - 700V (0 -14mA) Output 25 mA Isolation 2.5 kV Bandwidth DC-25 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 90°C Accuracy 0.9% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    4 pcs in stock

    $162.00
    $191.16 inclGST

  • LTC 600/SP02A(LA600-T), C/L Hall Effect Current Sensor, 600 Amp, 100mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.7%

    LTC 600/SP02A(LA600-T), C/L Hall Effect Current Sensor, 600 Amp, 100mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.7%

    Out of stock

    LEM LTC 600/SP02A(LA600-T) Open Loop AC/DC Hall Effect Sensor Features To replace LA 600-T Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 with Busbar and Feet Kit(not shown) Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600/SP02A(LA600-T) Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details

    Out of stock

    $770.50
    $909.19 inclGST

  • LTC 600-S, C/L Hall Effect Current Sensor, 400 Amp, 100mA Output, +/-15..24V, Panel Mount, ø42mm, X = 0.7%

    LTC 600-S, C/L Hall Effect Current Sensor, 400 Amp, 100mA Output, +/-15..24V, Panel Mount, ø42mm, X = 0.7%

    Out of stock

    LEM LTC 600-S Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600-S Technology Closed Loop Hall Effect Aperture ø42mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details

    Out of stock

    $741.80
    $875.32 inclGST

  • HASS 100-S, O/L Hall Effect Current Sensor, Panel Mount, 100 Amp, 5 VDC Supply, 2.5 Vref Output, Panel Mount 10.4 x 20.4mm sqr

    HASS 100-S, O/L Hall Effect Current Sensor, Panel Mount, 100 Amp, 5 VDC Supply, 2.5 Vref Output, Panel Mount 10.4 x 20.4mm sqr

    20 pcs in stock

    LEM HASS 100-S Series Open Loop AC/DC Hall Effect Sensor Features 5VDC Unipolar Supply Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HASS 100-S Technology Open Loop Hall Effect Aperture 20.4 x 10.4mm Square ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 100 Amp Measurement Range +/-300 Amp Output 2.5 Vref Isolation 3.3 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    20 pcs in stock

    $39.90
    $47.08 inclGST

  • LV 100-500, C/L Voltage Transducer, 500V, +/-15VDC Aux, 50mA Output

    LV 100-500, C/L Voltage Transducer, 500V, +/-15VDC Aux, 50mA Output

    Out of stock

    LEM LV 100-500 C/L Voltage Transducer, 500V, +/-15VDC Aux, 50mA Output Features Bipolar and insulated voltage measurement up tp 750VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100-500 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary RMS Voltage 500V Measurement Range +/- 750 V Output 50 mA Isolation 9 kV Response 190uS Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet

    Out of stock

    $879.30
    $1,037.57 inclGST

  • Last stock! HLSR 10-SM/SP33, O/L Hall Effect Current Sensor, 10 Amp, 0-3.3V Out, Surface Mount

    HLSR 10-SM/SP33, O/L Hall Effect Current Sensor, 10 Amp, 0-3.3V Out, Surface Mount

    2 pcs in stock

    LEM HLSR 10-SM/SP33 Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output 4.3kV Isolation Frequency bandwidth 400kHz Single supply + 3.3 V Galvanic isolation between primary and secondary Low power consumption Compact design for Surface mount PCB mounting Factory calibrated. High bandwidth, very low loss magnetic core Advantages Extremely low profile: h = 12mm Low foot-print Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box MPPT Standards EN 50178: 1997 UL 508: 2010 IEC 61326-1: 2012 IEC 61010-1: 2010 (safety) Application Domain Industrial Specification LEM Part Number HLSR 10-SM/SP33 Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 10 Amp Measurement Range +/-25 Amp Output 1.65 Vref Isolation 4.3 kV Bandwidth DC-450 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 5g Factory Packaging 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    2 pcs in stock

    $17.08
    $20.15 inclGST

  • HLSR 10-SM, O/L Hall Effect Current Sensor, 10 Amp, 5VDC Supply, Surface Mount

    HLSR 10-SM, O/L Hall Effect Current Sensor, 10 Amp, 5VDC Supply, Surface Mount

    Out of stock

    LEM HLSR 10-SM Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output 4.3kV Isolation Frequency bandwidth 400kHz Single supply + 5 V Galvanic isolation between primary and secondary Low power consumption Compact design for Surface mount PCB mounting Factory calibrated. High bandwidth, very low loss magnetic core Advantages Extremely low profile: h = 12mm Low foot-print Low offset drift Over-drivable VREF Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box MPPT Standards EN 50178: 1997 UL 508: 2010 IEC 61326-1: 2012 IEC 61010-1: 2010 (safety) Application Domain Industrial Specification LEM Part Number HLSR 10-SM Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 10 Amp Measurement Range +/-25 Amp Output 2.5 Vref Isolation 4.3 kV Bandwidth DC-450 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Unit Weight 5g Factory Packaging 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $27.60
    $32.57 inclGST

  • 93.34.43.100.0, Feet fixing kit for use with LEM LTC 200/350/400/500-S

    93.34.43.100.0, Feet fixing kit for use with LEM LTC 200/350/400/500-S

    46 pcs in stock

    Feet fixing kit for use with LEM LTC 200/350/400/500-S Product Datasheet

    46 pcs in stock

    $27.60
    $32.57 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account