  • HAS 100-S, O/L Hall Effect Current Sensor, Panel Mount, 100 Amp, +/- 4V Output,10.4 x 20.4mm sqr

    HAS 100-S, O/L Hall Effect Current Sensor, Panel Mount, 100 Amp, +/- 4V Output,10.4 x 20.4mm sqr

    77 pcs in stock

    LEM HAS 100-S Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAS 100-S Technology Open Loop Hall Effect Aperture 20.4 x 10.4mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 100 Amp Measurement Range +/-300 Amp Output +/-4 V Isolation 3.6 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    77 pcs in stock

    $62.59
    $73.86 inclGST

  • Last stock! DHR 300 C420, Hall Effect Current Sensor, 300Amp , True RMS 4-20mA output

    DHR 300 C420, Hall Effect Current Sensor, 300Amp , True RMS 4-20mA output

    4 pcs in stock

    LEM DHR 300 C420, Hall Effect Current Sensor, 300Amp , True RMS 4-20mA output Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ?32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 300 C420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 300 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6   Datasheet Product Datasheet

    4 pcs in stock

    $394.00
    $464.92 inclGST

  • DHAB S/106, O/L Automotive AC/DC Current Transducer, Multirange +/-20A +/-500A, 5VDC Supply, 22.5mm Round Aperture

    DHAB S/106, O/L Automotive AC/DC Current Transducer, Multirange +/-20A +/-500A, 5VDC Supply, 22.5mm Round Aperture

    124 pcs in stock

    LEM DHAB S/106, O/L Automotive AC/DC Current Transducer, Multirange +/-20A +/-500A, 5VDC Supply, 22.5mm Round Aperture Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range up to +/-20A, and +/-500A for Channel 2 Maximum RMS primary admissable current: defined by busbar to have T° < +150°C Operating Temperature Range: -40°C < T° < +125°C Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles   Specification LEM Part Number DHAB S/106 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-20 Amp Load Current Channel 2 (RMS) +/-500 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth(-3dB) DC - 70Hz Mounting Style Panel Mount/Cable Mount Aperture ⌀22.5mm Operating Temperature Range -40°C - 70°C CH1 Accuracy @ 25 Deg C 0.15%(0A),0.30%(10A),0.4%(20A) CH2 Accuracy @ 25 Deg C 1.5%(0A),6%(250A),9%(500A) Termination Style TYCO 1-1456426-5 Unit Weight 100g Factory Pack Qty 6   Datasheet Product Datasheet

    124 pcs in stock

    $75.00
    $88.50 inclGST

  • Last stock! ART-B22-D175-SP3 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter ART-B22-D175-SP3 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter

    ART-B22-D175-SP3 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 17.5cm Diameter

    4 pcs in stock

    LEM ART-B22-D175-SP3 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coils & Universal Multi Range Integrator with Signal Conditioner The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D175-SP3 + AI-PMUL - 3 Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    4 pcs in stock

    $1,285.00
    $1,516.30 inclGST

  • LEM International SA Rogowski Coil AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input and Output, up to 5000Amp Measurement, Din Rail Mount FE-Integrator AI-PMUL

    AI-PMUL Universal Integrator for Rogowski Coils, Input (100 to 5000 Amp) and Output (0.333V,0.225V), and True RMS outputs (4-20mA,0-20mA,0-5V,0-10V), Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount

    53 pcs in stock

    LEM AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input (100 to 5000 Amp) and Output (0.333V,0.225), and True RMS outputs (4-20mA,0-20mA,0-5V,0-10V), Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both True RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. optional Input signal Accuracy Class 0.5 (IEC 61869-2) [1]. Linearity error ? 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature ?25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 0.5 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross power plugin connector: side contacts to stack up to 3 Integrator modules and use only one power supply. 24VDC Power Supply Meanwell HDR-15-24 Specification LEM Part Number AI-PMUL Function Integrator and True RMS Conditioner for Rogowski Coils Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 0.5% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm Mounting Din Rail Mount Integrator to Meter cable User Supplied Shielded cable 6mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet Product Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    53 pcs in stock

    $389.20
    $459.26 inclGST

  • LT 2005-S, C/L Current Transducer, Ipn = 2000A, +/-15/24VDC, 400mA Output, X = 0.3%

    LT 2005-S, C/L Current Transducer, Ipn = 2000A, +/-15/24VDC, 400mA Output, X = 0.3%

    13 pcs in stock

    LEM LT 2005-S, C/L Current Transducer, Ipn = 2000A, +/-15/24VDC, 400mA Output, X = 0.3% Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 2005-S Technology Closed Loop Hall Effect Aperture ø60.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/- 3000 Amp Output 400 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.3% Termination Style M5 theaded studs Unit Weight 0.55kg Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    13 pcs in stock

    $1,029.00
    $1,214.22 inclGST

  • LA 25-NP/SP11, C/L Hall Effect Current Sensor, 1 Amp, 25mA Output, PCB Mount, No Aperture

    LA 25-NP/SP11, C/L Hall Effect Current Sensor, 1 Amp, 25mA Output, PCB Mount, No Aperture

    Out of stock

    LEM LA 25-NP/SP11, C/L Hall Effect Current Sensor, Multi Range 1 Amp, 25mA Output, PCB Mount, No Aperture Features Bandwidth DC to 150kHz Closed loop transducer using Hall effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LA25-NP/SP11 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 mA Measurement Range +/-1.5 Amp Output 25 mA Isolation 2.5 kV Bandwidth DC-150 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 0.5% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $74.20
    $87.56 inclGST

  • HTA 200-S, O/L Hall Effect Current Sensor, 200 Amp, +/-4V Output

    HTA 200-S, O/L Hall Effect Current Sensor, 200 Amp, +/-4V Output

    55 pcs in stock

    LEM HTA 200-S Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 1000 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTA 200-S Technology Open Loop Hall Effect Aperture ø32mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/-600 Amp Output +/-4 V Isolation 4 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 230g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    55 pcs in stock

    $147.35
    $173.87 inclGST

  • HAZ 4000-SB, O/L Hall Effect Current Transducer, 4000A, +/-10V Instant Output, +/-15V supply-AC/DC Current Hall Effect Sensor-LEM International SA-Fastron Electronics Store HAZ 4000-SB, O/L Hall Effect Current Transducer, 4000A, +/-10V Instant Output, +/-15V supply

    HAZ 4000-SB, O/L Hall Effect Current Transducer, 4000A, +/-10V Instant Output, +/-15V supply

    13 pcs in stock

    LEM HAZ 4000-SB, O/L Hall Effect Current Transducer, 4000A, +/-10V Instant Output, +/-15V supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide current ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 4000-SB Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 4000 Amp Overload Rating 30000 At Output +/-10 V Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    13 pcs in stock

    $1,289.00
    $1,521.02 inclGST

  • DVL 2000, Digital Voltage Transducer 2000V, +/-15...24VDC Supply, 50mA Output, 8.5kV Isolation

    DVL 2000, Digital Voltage Transducer 2000V, +/-15...24VDC Supply, 50mA Output, 8.5kV Isolation

    16 pcs in stock

    LEM DVL 2000 Series Closed Loop AC/DC Digital Voltage Transducer 2000V Input, 50mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    16 pcs in stock

    $565.00
    $666.70 inclGST

  • AT 20  B10, AC Current Transformer, Self Powered, 20 Amp Average RMS 0-10V output

    AT 20 B10, AC Current Transformer, Self Powered, 20 Amp Average RMS 0-10V output

    Out of stock

    LEM AT 20 B10, AC Current Transformer, Self Powered, 20 Amp Average RMS 0-10V output Features Split Core 0-10V Average RMS Output Cable Mounting Self Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ? 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 20 B10 Technology AC Current Transformer Protection Class IP50 Supply Voltage Self Powered Load Current (RMS) 20 Amp Maximum Measurement Current (RMS) 24 Amp Output 0-10V (Average RMS) Isolation 3.5kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 1.5% Aperture ? 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 90g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    $125.01
    $147.51 inclGST

  • 93.30.R2.000.0, Din Rail Clip for DVC 1000, DVC 1000-B, DVC 1000-UI, DVC 50

    93.30.R2.000.0, Din Rail Clip for DVC 1000, DVC 1000-B, DVC 1000-UI, DVC 50

    105 pcs in stock

    LEM 93.30.R2.000.0, Din Rail Clip for DVC 1000, DVC 1000-B, DVC 1000-UI, DVC 50      

    105 pcs in stock

    $7.00
    $8.26 inclGST