  • Last stock! FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    5 pcs in stock

    LEM FRS 3000-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 3000-SUI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 3000 Amp Measurement Range +/-9000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    5 pcs in stock

    $495.00
    $584.10 inclGST

  • Last stock! FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    5 pcs in stock

    LEM FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SUI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    5 pcs in stock

    $495.00
    $584.10 inclGST

  • Last stock! FRS 2000-SUI, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output FRS 2000-SUI, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    FRS 2000-SUI, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    5 pcs in stock

    LEM FRS 2000-SUI, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2000-SU Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/-6000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    5 pcs in stock

    $495.00
    $584.10 inclGST

  • Last stock! FRS 1500-SUI, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output FRS 1500-SUI, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    FRS 1500-SUI, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    5 pcs in stock

    LEM FRS 1500-SUI, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1500-SUI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1500 Amp Measurement Range +/-4500 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    5 pcs in stock

    $495.00
    $584.10 inclGST

  • Last stock! FRS 1000-SUI, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output FRS 1000-SUI, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    FRS 1000-SUI, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output

    3 pcs in stock

    LEM FRS 1000-SUI, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coresless Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1000-SUI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-3000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    3 pcs in stock

    $495.00
    $584.10 inclGST

  • HAH1BV S/24, Automotive Open Loop Current Sensor, -200/+400Amp Measurement, Vref = 2.5V output

    HAH1BV S/24, Automotive Open Loop Current Sensor, -200/+400Amp Measurement, Vref = 2.5V output

    Out of stock

    HAH1BV S/08, Automotive Open Loop HAH1BV S/24, Automotive Open Loop Current Sensor, -200/+400Amp Measurement, Vref = 2.5V output Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Ranges up to +/-900Amp Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles   Specification LEM Part Number HAH1BV S/24 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current  -200/+400 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2kV (AC, 50Hz, 1 min) Mounting Style Panel Mount/Cable Mount Termination Style Fuse Mounting Style Unit Weight 25g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    $39.00
    $46.02 inclGST

  • EM4TII + RS Data Interface, Class 0.5R, 4 Channel On Boad Rail Meter, RS Data Port, GPS Receiver, AC or DC Measurement via Transducers or CT's, 24-110VDC Aux supply

    EM4TII + RS Data Interface, Class 0.5R, 4 Channel On Boad Rail Meter, RS Data Port, GPS Receiver, AC or DC Measurement via Transducers or CT's, 24-110VDC Aux supply

    Out of stock

    EM4TII + RS Data Interface, Class 0.5R, 4 Channel On Boad Rail Meter, RS Data Port, GPS Receiver, AC or DC Measurement via Transducers or CT's, 24-110VDC Aux supply Dte and Time stamped Events Train Identification Numbers Absolute energy values for consumption and regeneration of active and reactive energy Backlit LCD 24-110VDC Aux Supply Voltage measurement of 16.7Hz, 50Hz, 60Hz, or DC energy User load profile and location stored  Voltage detect feature Meter Operating Temperature -40°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Dot Matrix LCD with illumination Specification Eastron Part Number DCM650-H Functions DC Energy Meter Supply Voltage 9-40VDC Nominal Measurement Range AC:70-300V or 17.9 - 100mA  DC:17.9 - 100mA Maximum Measurement Range 6400V via DV 6400 Hall Sensor Nominal Current Input Via external Current Transformer 1-5 Amp rms  or 25-1000mA, DC: 25-2000mA via external Hall Sensor Comms RS232/RS485(RS422) according to EN 50463-3 and IEC 62056-21 Accuracy Class 0.5R Mounting Panel Mount Real Time Clock Yes / time stamped data Sampling interval 4800Hz Dimensions 165 x 289 x 70 mm (W x H x D) GPS / GSM GPS receiver as standard / GSM via external 3rd party Modem Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms 3 x RS485 Modbus RTU 4800-115200bps (192000bps default) Weight 1.5kg Standards Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -40 →+70°C (Meter), -40 →+85 °C   Datasheet Product Datasheet User Manual TEMA 4G User Guide

    Out of stock

    $11,800.00
    $13,924.00 inclGST

  • HTA 1000-S/SP16, O/L Hall Effect Current Sensor, 1000 Amp, +/-10V Output

    HTA 1000-S/SP16, O/L Hall Effect Current Sensor, 1000 Amp, +/-10V Output

    Out of stock

    LEM HTA 1000-S/SP16, O/L Hall Effect Current Sensor, 1000 Amp, +/-10V Output Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 1000 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTA 1000-S/SP16 Technology Open Loop Hall Effect Aperture ø32mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-1000 Amp Output +/-10 V Isolation 4 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 230g Factory Pack Quantity 10   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $221.30
    $261.13 inclGST

  • HAT 1000-S/SP1, O/L Hall Effect Current Transducer, 1000 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output

    HAT 1000-S/SP1, O/L Hall Effect Current Transducer, 1000 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output

    18 pcs in stock

    LEM HAT 1000-S/SP1, O/L Hall Effect Current Transducer, 1000 Amp, +/-15V Supply, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 1000-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-2500 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    18 pcs in stock

    $179.00
    $211.22 inclGST

  • HAZ 4000-SBI, O/L Hall Effect Current Transducer, 4000A, +/-20mA Instant Output, +/-15VDC supply-AC/DC Current Hall Effect Sensor-LEM International SA-Fastron Electronics Store HAZ 4000-SBI/SP1, O/L Hall Effect Current Transducer, 4000A, 4-20mA Bipolar Instant Output, +/-15VDC supply

    HAZ 4000-SBI/SP1, O/L Hall Effect Current Transducer, 4000A, 4-20mA Bipolar Instant Output, +/-15VDC supply

    8 pcs in stock

    LEM HAZ 4000-SBI/SP1, O/L Hall Effect Current Transducer, 4000A, 4-20mA Bipolar Instant Output, +/-15VDC supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version 4-20mA 4mA(-Ipn), 12mA (Ipn = 0), 20mA (+Ipn) Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide current ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 4000-SBI/SP1 Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 4000 Amp Overload Rating 30000 At Output 4-20 mA Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    8 pcs in stock

    $1,289.00
    $1,521.02 inclGST

  • FCT-D16-5-010, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 0-10V LOOP POWERED Average RMS output, Class 0.5, 50-400 Hz Operation FCT-D16-5-010, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 0-10V LOOP POWERED Average RMS output, Class 0.5, 50-400 Hz Operation

    FCT-D16-5-010, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 0-10V LOOP POWERED Average RMS output, Class 0.5, 50-400 Hz Operation

    Out of stock

    Fastron FCT-D16-5-010, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 0-10V LOOP POWERED Average RMS output, Class 0.5, 50-400 Hz Operation Features Average RMS Output Split Core 0-10V Current Output Cable Mounting 24VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number FCT-D16-5-010 Technology AC Current Transformer Protection Class IP50 Supply Voltage 24VDC Loop Powered (10mA) Load Current (RMS) 5 Amp Maximum Measurement Current (RMS) 6 Amp Output 0-10V (Average RMS) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50 - 400Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 0.5% Aperture 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 140g Factory Pack Qty 6   Datasheet Product Datasheet  

    Out of stock

    $82.00
    $96.76 inclGST

  • HAH1DRW 700-S/SP5, Automotive Open Loop Current Sensor, +/-700Amp Measurement, Vref = 2.5V output

    HAH1DRW 700-S/SP5, Automotive Open Loop Current Sensor, +/-700Amp Measurement, Vref = 2.5V output

    Out of stock

    HAH1DRW 700-S/SP5, Automotive Open Loop Current Sensor, +/-700Amp Measurement, Vref = 2.5V output Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Ranges up to +/-900Amp Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles   Specification LEM Part Number HAH1DRW 700-S/SP5 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current  +/-700 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2kV (AC, 50Hz, 1 min) Mounting Style Panel Mount/Cable Mount Termination Style Fuse Mounting Style Unit Weight 25g Factory Pack Qty 6   Datasheet Product Datasheet

    Out of stock

    $59.00
    $69.62 inclGST