3 Phase Power Meter

15 products

  • Last stock! MC350H S ARNG SJUNNAT, Panel Mount Network Recorder with Harmonics (31st), Class 1, 50..500VAC 50/60Hz 61 Parameter Measurement, Universal 20..300V DC, 48..276VAC Aux, 8MB Logging Memory-kWh Meter-Iskra Doo-Fastron Electronics Store

    MC350H S ARNG SUNNAT, Panel Mount Network Recorder with Harmonics (31st), Class 1, 50..500VAC 50/60Hz 61 Parameter Measurement, Universal 20..300V DC, 48..276VAC Aux, 8MB Logging Memory

    2 pcs in stock

    MC350H S ARNG SUNNAT, Panel Mount Network Recorder with Harmonics (31st), Class 1, 50..500VAC 50/60Hz 61 Parameter Measurement, Universal 20..300V DC, 48..276VAC  Aux, 8MB Logging Memory Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Includes Harmonics Accuracy class 0.5 Measurement of 20 minimal and maximal values in different time periods Optional dual tariff inputs and pulse or relay outputs Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 600 V Multilingual support User-friendly PC MiQen software Specification Iskra Doo Part Number MC350H S ARNG SUNNAT Functions Power Quality Meter, Energy Meter Supply Voltage Universal 20..300V DC, 48..276VAC Nominal Measurement Range 500V L-N, 5 Amp  50/60Hz Maximum Measurement Range 600V L-N, 12.5 Amp   50/60Hz Alarm Optional 2 Relay/Pulse Outputs Tariff/Digital Inputs Optional 2 x Digital or Tarrif Inputs Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional 2 x Programmable Analogue Outputs Internal Memory 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Through Hole CT Weight 500g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet User Manual  

    2 pcs in stock

    $675.00
    $796.50 inclGST

  • Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Out of stock

    Secure Elite E500C-5402, Panel Mount Network Recorder with Harmonics (31st) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Dual Loggers, configurable for Instant or accumulated energy Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500C-5202 Functions Power Quality Meter (31st Hamonic), Energy Meter, Network Recorder Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 1/5 Amp, 415V L-L 1/5 Amp Maximum Measurement Range 300V L-N, 1/5 Amp, 500V L-L 1/5 Amp Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300   ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650   ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760   ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330   ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60   PM 5560   ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60   DM6200H   ACCUVIM-EL (+ IEC 61850)     PM2220   ACCUVIM-II R +Ethernet     PM2230 / DM2120 (LED)         PM 5350        

    Out of stock

    $725.00
    $855.50 inclGST

  • NP40-000M0, Portable Power Quality Analyser with built in Logger and Comms

    NP40-000M0, Portable Power Quality Analyser with built in Logger and Comms

    Out of stock

    Portable Power Quality Analyser with built in Logger Enjoy the convenience of portability and all the usual functionality you expect from a power quality analyser. The NP40 portable power quality analyser can assess your system’s power quality, supply power quality data, provide harmonics analysis, and much more. This portable power quality analyser comes with a built in logger and comms, and that’s just the start of the features you can expect. Among other things, this power quality analyser includes waveform real-time display, intuitive operation, transient capture functionality, 128MB of Flash Memory, and an 8GB built-in memory card slot. You will never be left without convenience or functionality with this power quality analyser. It is also available with a range of accessories, including a power adapter, a carry bag, crocodile clips, and software for your PC. View the full range of features, accessories, specifications, brochures, and user manuals now.   Lumel NP40-000M0, Portable Power Quality Analyser with built in Logger and Ethernet/USB Comms Main Features Waveform real-time display(4 voltages/4 currents) Half cycle RMS measurement (voltage and current) intuitive operation variety of optional current clamps Measure DC component Measurement, calculation and display of harmonics and interharmonics can be up to 50 times Transient capture Vector, Trend, Bar Graph and events table display Active power, reactive power, apparent power and energy, shift power factor and true power factor Three-phase unbalance (voltage and current) Flicker Inrush current Detection and record of Dips& Swells, Voltage Rapid Change, Interruption Detect according to EN50160 or grid with user-defined limit. Data storage and screenshots (can be replayed or output to a PC) Through the Ethernet interface, PC can keep real-time remote communication with the Analyzer, operate the Analyzer and read back measurement data. Built-in 8GB memory card Slot. 128MB Flash Memory Comes with the following Accessories 1 x NP40 Power Quality Analyzer 1 x Program software for PC (CD) 5 x 2-meter-long voltage cable (with 4mm caliber banana plug) 5 x Crocodile clip 1 x Power adapter 1 x Power cord 1 x Bag Hang strap Specification Lumel Part Number NP40-000M0 Voltage Measurement Range 0.01 - 1000 VAC/DC True RMS Impedance Measurement Range 1Ω - 9999Ω Current Measurement Range 0.1 - 3000 Amp AC/DC True RMS Flicker Measurement Range 0.1 - 20.0 Bandwidth DC to 3.5kHz Battery Voltage 7.4VDC Lithium Rechargable (6 Hours) Power Measurement Range 0.0001 - 20MW/GWh Flash Memory (Internal) 128MB TF Card 8GB Harmonics Measurement Range 50th Harmonic Weight 1.6kg Factory Pack Qty 1 EMC EN61326: 2002 Class B CE Yes   Datasheet Product Brochure User Manual

    Out of stock

    $4,677.00
    $5,518.86 inclGST

  • NP45-000M0, Portable Power Quality Analyser with TFT Touch Screen, built in Logger and Comms

    NP45-000M0, Portable Power Quality Analyser with TFT Touch Screen, built in Logger and Comms

    Out of stock

    NP45-000M0, Portable Power Quality Analyser with TFT Touch Screen, built in Logger and Comms Enjoy the convenience of portability and all the usual functionality you expect from a power quality analyser. The NP45 portable power quality analyser with TFT Touch Screen can assess your system’s power quality, supply power quality data, provide harmonics analysis, and much more. This portable power quality analyser comes with a built in logger and comms, and that’s just the start of the features you can expect. Among other things, this power quality analyser includes waveform real-time display, intuitive operation, transient capture functionality, 128MB of Flash Memory, and an 8GB built-in memory card slot. You will never be left without convenience or functionality with this power quality analyser. It is also available with a range of accessories, including a power adapter, a carry bag, crocodile clips, and software for your PC. View the full range of features, accessories, specifications, brochures, and user manuals now.   Lumel NP40-000M0, Portable Power Quality Analyser with built in Logger and Ethernet/USB Comms Main Features Waveform real-time display(4 voltages/4 currents) Half cycle RMS measurement (voltage and current) intuitive operation variety of optional current clamps Measure DC component Measurement, calculation and display of harmonics and interharmonics can be up to 50 times Transient capture Vector, Trend, Bar Graph and events table display Active power, reactive power, apparent power and energy, shift power factor and true power factor Three-phase unbalance (voltage and current) Flicker Inrush current Detection and record of Dips& Swells, Voltage Rapid Change, Interruption Detect according to EN50160 or grid with user-defined limit. Data storage and screenshots (can be replayed or output to a PC) Through the Ethernet interface, PC can keep real-time remote communication with the Analyzer, operate the Analyzer and read back measurement data. Built-in 8GB memory card Slot. 128MB Flash Memory Comes with the following Accessories 1 x NP40 Power Quality Analyzer 1 x Program software for PC (CD) 5 x 2-meter-long voltage cable (with 4mm caliber banana plug) 5 x Crocodile clip 1 x Power adapter 1 x Power cord 1 x Bag Hang strap Specification Lumel Part Number NP45-000M0 Voltage Measurement Range 0.01 - 1000 VAC/DC True RMS Impedance Measurement Range 1Ω - 9999Ω Current Measurement Range 0.1 - 3000 Amp AC/DC True RMS Flicker Measurement Range 0.1 - 20.0 Bandwidth DC to 3.5kHz Battery Voltage 7.4VDC Lithium Rechargable (6 Hours) Power Measurement Range 0.0001 - 20MW/GWh Flash Memory (Internal) 128MB TF Card 8GB Harmonics Measurement Range 50th Harmonic Weight 1.6kg Factory Pack Qty 1 EMC EN61326: 2002 Class B CE Yes   Datasheet Product Brochure User Manual

    Out of stock

    $7,990.00
    $9,428.20 inclGST

  • Last stock! E500C-5202, Panel Mount Network Recorder with Harmonics (15th) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty E500C-5202, Panel Mount Network Recorder with Harmonics (15th) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    E500C-5202, Panel Mount Network Recorder with Harmonics (15th) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    4 pcs in stock

    Secure Elite E500C-5202, Panel Mount Network Recorder with Harmonics (15th) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Dual Loggers, configurable for Instant or accumulated energy Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500C-5202 Functions Power Quality Meter(15th Hamonic), Energy Meter, Network Recorder Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 1/5 Amp, 415V L-L 1/5 Amp Maximum Measurement Range 300V L-N, 1/5 Amp, 500V L-L 1/5 Amp Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300   ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650   ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760   ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330   ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60   PM 5560   ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60   DM6200H   ACCUVIM-EL (+ IEC 61850)     PM2220   ACCUVIM-II R +Ethernet     PM2230 / DM2120 (LED)         PM 5350        

    4 pcs in stock

    $695.00
    $820.10 inclGST

  • Elite E500R-54D2, Panel Mount Power Quality Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (31st), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Elite E500R-54D2, Panel Mount Power Quality Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (31st), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Elite E500R-54D2, Panel Mount Power Quality Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (31st), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Out of stock

    Secure Elite E500R-54D2, Panel Mount Power Quality Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (31st), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-51D2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 1000A/140mm  Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L  Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L  Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300   ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650   ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760   ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330   ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60   PM 5560   ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60   DM6200H   ACCUVIM-EL (+ IEC 61850)     PM2220   ACCUVIM-II R +Ethernet     PM2230 / DM2120 (LED)         PM 5350        

    Out of stock

    $1,580.00
    $1,864.40 inclGST

  • Elite E500R-53C2, Panel Mount Network Recorder & 1000A/70mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Elite E500R-53C2, Panel Mount Network Recorder & 1000A/70mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Elite E500R-53C2, Panel Mount Network Recorder & 1000A/70mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Out of stock

    Secure Elite E500R-53C2, Panel Mount Network Recorder & 1000A/70mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz , RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-53C2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 1000A/70mm  Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L  Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L  Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300   ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650   ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760   ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330   ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60   PM 5560   ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60   DM6200H   ACCUVIM-EL (+ IEC 61850)     PM2220   ACCUVIM-II R +Ethernet     PM2230 / DM2120 (LED)         PM 5350        

    Out of stock

    $1,437.00
    $1,695.66 inclGST

  • Elite E500R-51E2, Panel Mount Network Recorder & 4000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Elite E500R-51E2, Panel Mount Network Recorder & 4000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Elite E500R-51E2, Panel Mount Network Recorder & 4000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Out of stock

    Secure Elite E500R-51E2, Panel Mount Network Recorder & 4000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-51E2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 4000A/140mm  Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L  Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L  Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300   ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650   ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760   ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330   ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60   PM 5560   ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60   DM6200H   ACCUVIM-EL (+ IEC 61850)     PM2220   ACCUVIM-II R +Ethernet     PM2230 / DM2120 (LED)         PM 5350        

    Out of stock

    $1,437.00
    $1,695.66 inclGST

  • E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Out of stock

    Secure E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, TFT Touch Screen Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-51D2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 1000A/140mm  Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L  Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L  Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300   ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650   ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760   ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330   ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60   PM 5560   ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60   DM6200H   ACCUVIM-EL (+ IEC 61850)     PM2220   ACCUVIM-II R +Ethernet     PM2230 / DM2120 (LED)         PM 5350        

    Out of stock

    $1,437.00
    $1,695.66 inclGST

  • Elite E500C-5102, Panel Mount Network Recorder with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Elite E500C-5102, Panel Mount Network Recorder with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Elite E500C-5102, Panel Mount Network Recorder with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty

    Out of stock

    Secure Elite E500C-5102, Panel Mount Network Recorder with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz  RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Dual Loggers, configurable for Instant or accumulated energy Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500C-5102 Functions Network Recorder, Energy Meter Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 1/5 Amp, 415V L-L 1/5 Amp Maximum Measurement Range 300V L-N, 1/5 Amp, 500V L-L 1/5 Amp Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300   ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650   ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760   ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330   ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60   PM 5560   ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60   DM6200H   ACCUVIM-EL (+ IEC 61850)     PM2220   ACCUVIM-II R +Ethernet     PM2230 / DM2120 (LED)         PM 5350        

    Out of stock

    $695.00
    $820.10 inclGST

  • MC770 S UENNCT, Power Quality AnalyserClass A, 3 Phase 4 Wire, 12.5Amp AC 50/60Hz  20-300VDC, 48-276VAC Power Supply  AC 16-400Hz, 140 Parameter, 8 Register, Ethernet Comms

    MC770 S UENNCT, Power Quality AnalyserClass A, 3 Phase 4 Wire, 12.5Amp AC 50/60Hz 20-300VDC, 48-276VAC Power Supply AC 16-400Hz, 140 Parameter, 8 Register, Ethernet Comms

    Out of stock

    Iskra Doo MC770 S UENNCT, Power Quality AnalyserClass A, 3 Phase 4 Wire, 12.5Amp AC 50/60Hz 20-300VDC, 48-276VAC Power Supply AC 16-400Hz, 140 Parameter, 8 Register, Ethernet Comms Smart Meter Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 750 V L-N 50/60Hz Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication   The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.   Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods Optional 32 adjustable alarms Optional wide frequency range from 16 Hz to 400 Hz Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Optional MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Specification Iskra Doo Part Number MC750 S SERNNT Functions Power Quality Meter, Energy Meter, Power Transducer, Network Recorder/Analyser Supply Voltage 240VAC < 5VA Nominal Measurement Range 500V L-N, 5 Amp 50/60Hz Maximum Measurement Range 750V L-N, 12.5 Amp 50/60Hz Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 512MB Isolation 3.7kV Ethernet Optional (RJ45 10/100Mbit/s) USB Yes (2400-115200 b/s) RS232/RS485 2400-115200 b/s Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997   Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22   Datasheet Product Datasheet User Manual  

    Out of stock

    $1,680.00
    $1,982.40 inclGST

  • MC350 S ARNG SJUNNAT, Panel Mount Network Recorder with Harmonics (31st), Class 1, Autroraning 50-500VAC 50/60Hz 61 Parameter Measurement, Universal 20..300V DC, 48..276VAC Aux, 8MB Logging Memory-kWh Meter-Iskra Doo-Fastron Electronics Store

    MC350 S ARNG SJUNNAT, Panel Mount Network Recorder with Harmonics (31st), Class 1, 50-500VAC 50/60Hz 61 Parameter Measurement, Universal 20..300V DC, 48..276VAC Aux, 8MB Logging Memory

    Out of stock

    Iskra Doo MC350 Series 3 Phase Network Recorder, with Harmonics Analysis to the 31st Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy class 1 Measurement of 20 minimal and maximal values in different time periods Optional dual tariff inputs and pulse or relay outputs Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 600 V Multilingual support User-friendly PC MiQen software Specification Iskra Doo Part Number MC350 S ARNG SJUNNAT Functions Power Quality Meter, Energy Meter Supply Voltage Universal 20..300V DC, 48..276VAC Nominal Measurement Range 500V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm Optional 2 Relay/Pulse Outputs Tariff/Digital Inputs N/A (Optional 2 x Digital or Tarrif Inputs) Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Outputs Optional 2 x Programmable Analogue Outputs Internal Memory 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Terminations Through Hole CT Weight 500g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual

    Out of stock

    $589.00
    $695.02 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account