IELHK1111-1REC4-64-4.00-AE-01-V, Air Pax DC Breaker 35 Amp DC, 50kA, 4 Pole, with Aux Contact, 2.8mm Quick Connect. Black with white markings
Features :
3 Pole
Auxiliary Contact
Applications :
On Board Vessel Earth Leakage Detection (Marine)
Hydraulic/Magnetic Circuit Protection
Specification
Sensata - Klixon Part Number
IELHK1111-1REC4-64-4.00-AE-01-V
Supply Voltage
240VAC
Dimensions
38.5mm x 80mm x 65mm
Application
Earth Leakage Detection 27mA - 50 Amp
Trip Level
27mA (30mA Nominal)
Relay
Requires Air Pax LEL Series Breaker 4 Pole
Protection
IP20
Approvals
E-11 GFP - UL 943 Category FTTJ2 when used in tandem with FPGM Marine Earth leakage Sensor
Trip Time of Assembly
100mS or Less (60mS nominal)
Sensing Coil Voltage Limit
600VAC max
Operating Temnperature
-35 to 66 Deg C
Weight
200g
Mounting Style
Din Rail
Datasheet
Product Datasheet
Air Pax CELHPK111-1REC4-52-300.-A-01-T, Hydraulic Magnetic Circuit Breaker 3 Pole 300 Amp 80VDC
Features :
Suitable for PGFM Series Earth Leakage Sensor
Applications :
On Board Vessel Earth Leakage Detection (Marine)
Hydraulic/Magnetic Circuit Protection
Specification
Sensata - Klixon - Air Pax Part Number
CELHPK111-1REC4-52-300.-A-01-T
Working Voltage
80VDC
Dimensions
58mm x 53mm
Application
Hydraulics or Magnetics
Trip Level
300 Amp
Relay
N/A
Protection
IP20
Approvals
TUV
Trip Time of Assembly
DC Long Delay
Sensing Coil Voltage Limit
80VDC
Operating Temnperature
-35 to 65 Deg C
Weight
300g
Mounting Style
Panel Mount
Datasheet
Product Datasheet
LEL12-1REC5-37583-30-G2-V, Magenetic Circuit Breaker 30mA to 50 Amp Range, 240VAC Supply, Panel Mount, Suitable for PGFM Series Earth Leakage System
Features :
Suitable for PGFM Series Earth Leakage Sensor
Applications :
On Board Vessel Earth Leakage Detection (Marine)
Hydraulic/Magnetic Circuit Protection
Specification
Sensata - Klixon Part Number
LEL12-1REC5-37583-30-G2-V
Supply Voltage
240VAC
Dimensions
38.5mm x 80mm x 65mm
Application
Earth Leakage Detection 27mA - 50 Amp
Trip Level
27mA (30mA Nominal)
Relay
Requires Air Pax LEL Series Breaker
Protection
IP20
Approvals
E-11 GFP - UL 943 Category FTTJ2 when used in tandem with FPGM Marine Earth leakage Sensor
Trip Time of Assembly
100mS or Less (60mS nominal)
Sensing Coil Voltage Limit
600VAC max
Operating Temnperature
-35 to 66 Deg C
Weight
200g
Mounting Style
Din Rail
Datasheet
Product Datasheet