Hall Effect Current Sensors

543 products

  • HAT 200-S, O/L Hall Efffect Current Transducer, 200 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    HAT 200-S, O/L Hall Efffect Current Transducer, 200 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    36 pcs in stock

    LEM HAT 200-S, O/L Hall Efffect Current Transducer, 200 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 200-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/-600 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    36 pcs in stock

    $128.00
    $151.04 inclGST

  • HAT 600-S, O/L Hall Effect Current Transducer, 600 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    HAT 600-S, O/L Hall Effect Current Transducer, 600 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    Out of stock

    LEM HAT 600-S, O/L Hall Effect Current Transducer, 600 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 600-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/-1800 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    $125.40
    $147.97 inclGST

  • HAT 400-S, O/L Hall Effect Current Transducer, 400 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    HAT 400-S, O/L Hall Effect Current Transducer, 400 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output

    8 pcs in stock

    LEM HAT 400-S, O/L Hall Effect Current Transducer, 400 Amp, +/-15VDC, 40.5 x 30.5 Square Aperture, +/-4V Output Features Bandwidth DC to 5kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 1500 A in one package. Up to 2500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAT 400-S Technology Open Loop Hall Effect Aperture 40.5 x 30.5mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 400 Amp Measurement Range +/-1200 Amp Output +/-4 V Isolation 4.9 kV Bandwidth DC-25 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 300g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    8 pcs in stock

    $95.00
    $112.10 inclGST

  • HASS 200-S, O/L Hall Effect Current Sensor, Panel Mount, 200 Amp, 5 VDC Supply, 2.5 Vref Output, Panel Mount 10.4 x 20.4mm sqr

    HASS 200-S, O/L Hall Effect Current Sensor, Panel Mount, 200 Amp, 5 VDC Supply, 2.5 Vref Output, Panel Mount 10.4 x 20.4mm sqr

    1291 pcs in stock

    LEM HASS 200-S Series Open Loop AC/DC Hall Effect Sensor Features 5VDC Unipolar Supply Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HASS 200-S Technology Open Loop Hall Effect Aperture 20.4 x 10.4mm Square ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 200 Amp Measurement Range +/-900 Amp Output 2.5 Vref Isolation 3.3 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    1291 pcs in stock

    $31.67
    $37.37 inclGST

  • HAS 200-S, O/L Hall Effect Current Sensor, Panel Mount, 200 Amp, +/-15 VDC Supply, +/- 4V Output

    HAS 200-S, O/L Hall Effect Current Sensor, Panel Mount, 200 Amp, +/-15 VDC Supply, +/- 4V Output

    102 pcs in stock

    LEM HAS Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAS 200-S Technology Open Loop Hall Effect Aperture 20.4 x 10.4mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/-600 Amp Output +/-4 V Isolation 3.6 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 60g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    102 pcs in stock

    $62.59
    $73.86 inclGST

  • HAL 50-S, O/L Hall Effect Current Sensor, 50 Amp, +/-4V Output, 15 x 20mm Aperture

    HAL 50-S, O/L Hall Effect Current Sensor, 50 Amp, +/-4V Output, 15 x 20mm Aperture

    27 pcs in stock

    HAL 50-S O/L Hall Effect Current Sensor, 50 Amp, +/-4V Output, 15x20mm sqr, X = 1% Features Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Advantages Wide dynamic range, 50 to 600 A in one package. Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAL 50-S Technology Open Loop Hall Effect Aperture 20 x 15mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 50 Amp Overload Capability 30,000 Amp Output +/-4 V Isolation 3 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-040A Unit Weight 75g Factory Pack Quantity 10 Datasheet Product Datasheet

    27 pcs in stock

    $110.64
    $130.56 inclGST

  • HAL 500-S, O/L Current Sensor, 500 Amp, +/-12/15VDC, +/-4V Output, 15 x 20mm Aperture

    HAL 500-S, O/L Current Sensor, 500 Amp, +/-12/15VDC, +/-4V Output, 15 x 20mm Aperture

    28 pcs in stock

    HAL 500-S O/L Current Sensor, 400Amp, +/-12/15VDC, 15 x 20mm Aperture, +/-4V Output Features Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Advantages Wide dynamic range, 50 to 600 A in one package. Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAL 500-S Technology Open Loop Hall Effect Aperture 20 x 15mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 500 Amp Overload Capability 30,000 Amp Output +/-4 V Isolation 3 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-040A Unit Weight 75g Factory Pack Quantity 10 Datasheet Product Datasheet

    28 pcs in stock

    $123.65
    $145.91 inclGST

  • Last stock! DHR 100 C10, Hall Effect Current Sensor 100Amp, True RMS 0-10V output

    DHR 100 C10, Hall Effect Current Sensor 100Amp, True RMS 0-10V output

    5 pcs in stock

    LEM DHR 100 C10, Hall Effect Current Sensor 100Amp, True RMS 0-10V output Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ?32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 100 C10 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 100 Amp Output 0-10V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6   Datasheet Product Datasheet

    5 pcs in stock

    $394.00
    $464.92 inclGST

  • HAX 1200-S O/L Current Transducer, 1000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    HAX 1200-S O/L Current Transducer, 1000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output

    10 pcs in stock

    LEM HAX 1200-S O/L Current Transducer, 1000 Amp, +/-15V Supply, 64 x 21 Square Aperture, +/-4V Output Features Bandwidth DC to 25kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, nominal 100 to 2500 A in one package. Up to 5500 A measurement range Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HAX 1200-S Technology Open Loop Hall Effect Aperture 64 x 21mm Square ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 1200 Amp Measurement Range +/-3600 Amp Overload Rating +/-30000 At Output +/-4 V Isolation 4.4 kV Bandwidth DC-25 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 450g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    10 pcs in stock

    $232.90
    $274.82 inclGST

  • Last stock! LF 2005-S/SP28, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply, SP28 = 12kV Isolation LF 2005-S/SP28, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply, SP28 = 12kV Isolation

    LF 2005-S/SP28, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply, SP28 = 12kV Isolation

    4 pcs in stock

    LEM LF 2005-S/SP28, C/L Hall Effect Current Sensor, 2000 Amp Input, 400mA Output, +/-15/24VDC Power Supply, SP28 = 12kV Isolation Features Bipolar and insulated current measurement up tp 3000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 SP28 = 12kV Isolation, M5 threaded inserts on secondary Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 2005-S/SP28 Technology Closed Loop Hall Effect Aperture ø60.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/- 3000 Amp Output 400 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style M5 Threaded Studs Unit Weight 1.5kg Factory Pack Quantity 9   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    4 pcs in stock

    $1,154.00
    $1,361.72 inclGST

  • ATO-CUS-DC20000-4000-420U, O/L Hall Effect Current Transducer, 0-4000A, 4-20mA Instant Output, +24VDC Supply

    ATO-CUS-DC20000-4000-420U, O/L Hall Effect Current Transducer, 0-4000A, 4-20mA Instant Output, +24VDC Supply

    Out of stock

    ATO-CUS-DC20000-4000-420U, O/L Hall Effect Current Transducer, 0-4000A, 4-20mA Instant Output, +24VDC Supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Insant output versions 4-20mA, 0-20mA, 0-10V, 0-5V output Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 2.5kV Rms /50 Hz /1min Low power consumption Package in ABS  Instantaneous voltage or current output options Advantages Easy installation Small size and space savings Only one design for wide current ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number ATO-CUS-DC20000-4000-420U Technology Open Loop Hall Effect ROHS Yes Supply Voltage +24VDC Load Current (RMS + DC) 4000 Amp Overload Rating N/A Output 4-20 mA Instantaneous Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Only Mounting Style Busbar or Panel Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2   Datasheet Product Datasheet

    Out of stock

    $1,489.00
    $1,757.02 inclGST

  • FRS 3000-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version FRS 3000-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version

    FRS 3000-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version

    Out of stock

    LEM FRS 3000-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 3000-SBIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 3000 Amp Measurement Range +/-9000 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    Out of stock

    $995.00
    $1,174.10 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account