Fastron SCT-F36 F50 FESCT-3000 FESCT-6000 Pricing

100 products

  • SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's

    26 pcs in stock

    Fastron Electronics SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F36-630-5A Technology Split Core AC Current Transformer Ratio 630/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 630Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    26 pcs in stock

    $66.50
    $78.47 inclGST

  • SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's SCT-F36-400-5A, 5 Amp, 400Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's

    84 pcs in stock

    Fastron Electronics SCT-F36-400-40mA, 40mA, 400Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F36-400-40mA Technology Split Core AC Current Transformer Ratio 400/040 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output .40 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    84 pcs in stock

    $66.50
    $78.47 inclGST

  • Last stock! SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's

    SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's

    2 pcs in stock

    Fastron Electronics SCT-F50-250-5A, 5 Amp, 250Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-250-5A Technology Split Core AC Current Transformer Ratio 250/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    2 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F36-500-5A, 5 Amp, 500Amp Measurement, Class 1 Split Core CT's SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-500-5A, 5 Amp, 500Amp Measurement, Class 1 Split Core CT's

    37 pcs in stock

    Fastron Electronics SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F36-500-5A Technology Split Core AC Current Transformer Ratio 500/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    37 pcs in stock

    $66.50
    $78.47 inclGST

  • SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's

    SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's

    35 pcs in stock

    Fastron Electronics SCT-F50-500-5A, 5 Amp, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-500-5A Technology Split Core AC Current Transformer Ratio 500/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    35 pcs in stock

    $110.55
    $130.45 inclGST

  • Last stock! SCT-F50-300-5A, 5 Amp, 300Amp measurement Split Core CT's SCT-F50-300-5A, 5 Amp, 300Amp measurement Split Core CT's

    SCT-F50-300-5A, 5 Amp, 300Amp measurement Split Core CT's

    2 pcs in stock

    Fastron Electronics SCT-F50-300-5A, 5 Amp, 300Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-300-5A Technology Split Core AC Current Transformer Ratio 300/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    2 pcs in stock

    $110.55
    $130.45 inclGST

  • Last stock! SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's

    SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's

    2 pcs in stock

    Fastron Electronics SCT-F50-200-5A, 5 Amp, 200Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-200-5A Technology Split Core AC Current Transformer Ratio 200/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    2 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F36-100-5A, 5 Amp, 100Amp Measurement, Class 1 Split Core CT's SCT-F36-300-5A, 5 Amp, 300Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-100-5A, 5 Amp, 100Amp Measurement, Class 1 Split Core CT's

    80 pcs in stock

    Fastron Electronics SCT-F36-100-5A, 5 Amp, 150Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-100-5A Technology Split Core AC Current Transformer Ratio 100/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    80 pcs in stock

    $66.50
    $78.47 inclGST

  • FESCT-51-800-0.333V, 800Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store FESCT-51-800-0.333V, 800Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    FESCT-51-1000-0.333V, 1000Amp measurement Split Core CT's, Class 1, w/1M Flying leads, 51x51mm Aperture

    17 pcs in stock

    Fastron Electronics FESCT-51-1000-0.333V, 1000Amp measurement Split Core CT's, w/1M Flying leads, 51x51mm Aperture, Class 1 Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Electronics Part Number FESCT-51-1000-0.333V Technology Split Core AC Current Transformer Ratio 1000/0.333V Aperture Size 51 x 51mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1000Amp x 1.2 Termination Style 1M Twisted Pair 0.34mm^2 Unit Weight 950g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    17 pcs in stock

    $105.00
    $123.90 inclGST

  • SCT-F50-250, 0.333V, 250Amp measurement Split Core CT's SCT-F50-250, 0.333V, 250Amp measurement Split Core CT's

    SCT-F50-250, 0.333V, 250Amp measurement Split Core CT's

    39 pcs in stock

    Fastron Electronics SCT-F50-250, 0.333V, 250Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-250 Technology Split Core AC Current Transformer Ratio 250/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    39 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F36-200-5A, 5 Amp, 200Amp Measurement, Class 1 Split Core CT's SCT-F36-300-5A, 5 Amp, 300Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-200-5A, 5 Amp, 200Amp Measurement, Class 1 Split Core CT's

    53 pcs in stock

    Fastron Electronics SCT-F36-200-5A, 5 Amp, 200Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F36-200-5A Technology Split Core AC Current Transformer Ratio 200/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    53 pcs in stock

    $66.50
    $78.47 inclGST

  • FESCT-3000-2000, 2000Amp 0.333V Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture

    FESCT-3000-2000, 2000Amp 0.333V Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture

    18 pcs in stock

    Fastron Electronics FESCT-3000-2000, 2000Amp 0.333V Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCT-3000-2000 Technology Split Core AC Current Transformer Ratio 2000/0.333V Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 0.333VAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 2000Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide

    18 pcs in stock

    $179.00
    $211.22 inclGST

Login

Forgot your password?

Don't have an account yet?