1/2" BSP/NPT x 6mm, Compression Fitting for use with RTD or Thermocouple, 304 SS Body with Brass Compression Ring Insert
1/2" BSP or NPT x 6mm
Stainless Steel
BSPT vs NPT Sizes
BSPT vs NPT Fittings
1/4" BSPT x 6mm Compression Fitting for use with RTD or Thermocouple, 304 SS Body with Brass Compression Ring Insert
Tapered 1/4" BSP x 6mm
Stainless Steel
BSPT vs NPT Sizes
BSPT vs NPT Fittings
Fastron Electronics GT-D-C-SP02, 0-150VDC Voltage Transducer, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-D-C-SP02
Control Output
4-20mA
Input
0 - 150VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
SSP-BLUE-4mm (2pcs), Blue 4mm Fully Sheathed Safety/Banana Plugs, 32 Amp, 1000V Rated. For Test Equipment/Leads (Current Clamps)
4mm
Fully Sheathed
Suitable for M1/M2 or other 4mm Current Clamps
32 Amp / 1000V AC (rms) or DC Maximum Rating
Fastron FDV-50-420-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-420-24
Analogue Output
4-20mA
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Â
HS211B, HS211B, Panel Mount Heat Sink, 2.7 Deg C per Watt (Heatsink Only), Suitable for FASTRON OR TRENT standard 44x57mm SSR Only EXCLUDES T(RENT FDH5048ZD3-2H
Features
Panel Mount heat sink
Suitable for SSR Mounting
Pre drilled for single or Dual SSR
Spec
Fastron Part Number
HS211B
Mounting Type
Panel Mount Only
Suitable SSR Rating
25 Amp
Dimensions (without SSR)
L:80mm x W:50mm x D:50mm
Thermal Impedance
2.7°C/W
Load Current @ 40 Deg C
21 Amp
Load Current @ 50 Deg C
17 Amp
Unit Weight
120g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FRT8-A2/W240, Delay On Timer 12-240 V AC/DC, 0.1s - 10 Days, 2 x SPDT 16 Amp
Features :
Multi-range (0.1s - 10days)
Multi-voltage 12 →240 V AC/DC
LED status indicator
Possibility of external load connection in parallel to the control input
Delay On Energisation
Specification
Fastron Part Number
FRT8-A2/W240
Function
Delay On Timer
Nominal Voltage
12 → 240 V AC/DC
Digital Output
2 x C/O (SPDT) (Changeover -Single Pole), 250VAC/DC @ 16 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 1s - 10 Days
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
80g
Factory Pack Qty
1
Certification
CE, RoHS
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Â
Datasheet
Product Datasheet
Fastron Monitoring/Time Relays Catalogue
For items in our catalogue which are not listed online please Contact Us for Possible Replacement
Alternative
 Double Delay On Timer Substitute FRT8-2T-W240
Â
Fastron F157F-1Z-C3 Series SPDT 10/16 Amp Socket for AC/DC Relay, 6-230VAC/DC Coil
Features
Rated for 1 x SPDT 10/16 Amp @ 250VAC or 30VDC
5 Pin Socket for F157 Series
Changeover Contact
Slim package
Compatible with Omron G2R-1-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
F157F-1Z-C3
Switching Type
1 x SPDT 30VDC/250VAC C/O
No. of Pins
5
Approvals
UL, CE
Rated Coil Voltage
up tp 250VAC/DC
Rated Load Current
1 x 10/16 Amp (rms)
Special Feature
Optional LED Status Indicator
Mounting Style
PCB or Socket Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Unit Weight
50g
Factory Pack Qty
20
Â
Datasheet
Relay Datasheet
Relay Replacement
F157FT/24 1ZT
F157FT/250VAC 1ZT
Fastron FRI 8-01/1, Current Monitoring Relay AC 0.1 - 1 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/1
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.1 - 1 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Fastron Electronics F13FT-2PL 12A 24VDC + F13FT-2Z-C4 Series Din Rail Mount Dual 12 Amp Form C AC/DC Relay, 24VDC Coil, PCB or Socket Mount
Features
2 x 12 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Compatible with Omron G2R-2-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Suits F13F-2Z-C4 Socket
Specification
Fastron Part Number
F13FT-2PL 12A 24VDC + F13FT-2Z-C4
Switching Type
2 x 30VDC/250VAC C/O DPDT Form C
No. of Pins
8
Approvals
UL,CE
Control Voltage
24VDC
Load Current
2 x 12 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
38g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Replacement Relay
F13FT-2PL 12A 24VDC
Replacement Socket
F13F-2Z-C4
SSP-RED-4mm (2pcs), RED 4mm Fully Sheathed Safety/Banana Plugs, 32 Amp, 1000V Rated. For Test Equipment/Leads (Current Clamps)
4mm
Fully Sheathed
Suitable for M1/M2 or other 4mm Current Clamps
32 Amp / 1000V AC (rms) or DC Maximum Rating
Fastron Electronics GT-DV6-D-1, Signal Isolator/DC Voltage Transducer, 0-300VDC input, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-DV6-D-1
Control Output
4-20mA
Input
0 - 300VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet