Earth Leakage Relays, Core Balanced CT's, DC Earth Leakage Sensors
-
RCR-V30-230V, Earth Leakage Relay 30mA to 30 Amp Range, 115VAC/230VAC Aux Supply, Din Rail Mount, 1 x SPDT, 1 x SPNO Relay
Hobut RCR-V30-230V, Earth Leakage Relay 30mA to 30 Amp Range, 115VAC/230VAC Aux Supply, Din Rail Mount, 1 x SPDT, 1 x SPNO Relay, Suitable Replacement to Schneider VigiPacT RH10M Features : Suitable for Core Balanced CT's CTB 35, CTB 50, CTB 70, CTB 120, CTB 160, CTB 210 Suitable Replacement to Schneider VigiPacT RH10M Applications : Earth Leakage Detection Specification Hobut Part Number RCR-V30-230V Supply Voltage 115VAC/230VAC @ 6VA Dimensions L:85mm x W:44mm xD:63.5mm Application Earth Leakage Detection Trip Setting Ranges 0.03,0.1,0.2,0.3,0.5,1,10,20,30 Amp Relay 1 x SPNO, 1 x SPDT Protection IP20 Approvals IEC 60755, 60947, 62020, 62543 Operating Temperature -20 to 55 Deg C Weight 200g Mounting Style Din Rail Datasheet Product Datasheet User Manual Application Notes RCR-V30 Installation Guide
$319.00
$376.42 inclGST -
RCR-V30-60VDC, Earth Leakage Relay 30mA to 30 Amp Range 10-60VDC Supply, Din Rail Mount, 1 x SPDT ,1 x SPNO Relay, Suitable Replacement to Schneider VigiPacT RH10M
Fastron RCR-V30-60VDC, Earth Leakage Relay 30mA to 30 Amp Range 10-60VDC Supply, Din Rail Mount, 1 x SPDT ,1 x SPNO Relay, Suitable Replacement to Schneider VigiPacT RH10M Features : Suitable for Core Balanced CT's CTB 35, CTB 50, CTB 70, CTB 120, CTB 160, CTB 210 Suitable Replacement to Schneider VigiPacT RH10M Applications : AC Earth Leakage Detection Specification Hobut Part Number RCR-V30-60VDC Supply Voltage 10-60VDC @ 6VA Dimensions L:85mm x W:44mm xD:63.5mm Trip Setting Ranges 0.03,0.1,0.2,0.3,0.5,1,10,20,30 Amp Application Earth Leakage Detection Relay 1 x SPNO, 1 x SPDT Protection IP20 Approvals IEC 60755, 60947, 62020, 62543 Operating Temperature -20 to 55 Deg C Weight 200g Mounting Style Din Rail Datasheet Product Datasheet User Manual Application Notes RCR-V30 Installation Guide
$319.00
$376.42 inclGST -
RCR-V30-400V, Earth Leakage Relay 30mA to 30 Amp Range, 400VAC Supply, Din Rail Mount, 1 x SPDT, 1 x SPNO Relay
Hobut RCR-V30-400V, Earth Leakage Relay 30mA to 30 Amp Range, 400VAC Supply, Din Rail Mount, 1 x SPDT, 1 x SPNO Relay, Suitable Replacement to Schneider VigiPacT RH10M Features : Suitable for Core Balanced CT's CTB 35, CTB 50, CTB 70, CTB 120, CTB 160, CTB 210 Suitable Replacement to Schneider VigiPacT RH10M Applications : Earth Leakage Detection Specification Hobut Part Number RCR-V30-400V Supply Voltage 400VAC @ 6VA Dimensions L:85mm x W:44mm xD:63.5mm Application Earth Leakage Detection Trip Setting Ranges 0.03,0.1,0.2,0.3,0.5,1,10,20,30 Amp Relay 1 x SPNO, 1 x SPDT Protection IP20 Approvals IEC 60755, 60947, 62020, 62543 Operating Temperature -20 to 55 Deg C Weight 200g Mounting Style Din Rail Datasheet Product Datasheet User Manual Application Notes RCR-V30 Installation Guide
$319.00
$376.42 inclGST -
CTB 210, 210mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s
Hobut CTB 210, 210Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTB 210 Technology Core Balanced/Toroid (CBCT) Aperture Size 210mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$386.00
$455.48 inclGST -
CTB 35, 35mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s
Hobut CTB 35, 35Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTB 35 Technology Core Balanced/Toroid (CBCT) Aperture Size 35mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$50.50
$59.59 inclGST -
Last stock!
RCD-V10 (917-651), Earth Leakage Relay 30mA to 10 Amp Range, 115/230VAC Supply, Din Rail Mount, 1 x SPDT, 1 x SPNO Relay
Hobut RCR-V10, Earth Leakage Relay 30mA to 10 Amp Range, 115/230VAC Supply, Din Rail Mount, 1 x SPDT, 1 x SPNO Relay, Suitable Replacement to Schneider VigiPacT RH10M Features : Suitable for Core Balanced CT's CTB 35, CTB 50, CTB 70, CTB 120, CTB 160, CTB 210 Suitable Replacement to Schneider VigiPacT RH10M Applications : Earth Leakage Detection Specification Hobut Part Number RCD-V10 (917-651) Supply Voltage 115/230VAC @ 6VA Dimensions L:85mm x W:44mm xD:63.5mm Setting Range 30mA to 10Amp Application Earth Leakage Detection Relay 1 x SPNO, 1 x SPDT Protection IP20 Approvals IEC 60755, 60947, 62020, 62543 Operating Temperature -20 to 55 Deg C Weight 200g Mounting Style Din Rail Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$463.00
$546.34 inclGST -
Last stock!
CTBR280-800A, Square Style Core Balanced CT's (CBCT) 100 x 280mm Internal Diameter
Hobut CTBR280-800A, Square Style Core Balanced CT's (CBCT) 100 x 280mm Internal Diameter Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTBR280-800A Technology Core balanced (CBCT) Aperture Size CTBR280-800A->100 x 280(290)mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$1,185.50
$1,398.89 inclGST -
ELR251-30A-230VAC, Earth Leakage Relay 30mA to 30A Continuously Variable Trip Setting Range, 230VAC Supply, Din Rail Mount, 1 x SPDT 10 Amp Relay
Free Aus Post Shipping for $300 SpendELR251-30A-230VAC, Earth Leakage Relay 30mA to 30A Continuously Variable Trip Setting Range, 230VAC Supply, Din Rail Mount, 1 x SPDT 10 Amp Relay Features : Suitable for Core Balanced CT's CTB 35, CTB 50, CTB 70, CTB 120, CTB 160, CTB 210 Applications : Earth Leakage Detection Specification Northern Design Part Number ELR251-30A-230VAC Supply Voltage 230VAC @ 6VA Dimensions L:85mm x W:44mm xD:63.5mm Trip Setting Range 30mA - 30Amp (AC) Application Earth Leakage Detection Relay 1 x SPDT 10 Amp Protection IP20 Approvals IEC 60755, 60947, 62020, 62543 Operating Temperature -20 to 55 Deg C Weight 400g Mounting Style Din Rail Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
Free Aus Post Shipping for $300 Spend$352.00
$415.36 inclGST -
CTB 160, 160mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s
Hobut CTB 160, 160Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTB 160 Technology Core Balanced/Toroid (CBCT) Aperture Size 160mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$226.00
$266.68 inclGST -
CTB 120, 120mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s
Hobut CTB 35, 35Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTB 120 Technology Core Balanced/Toroid (CBCT) Aperture Size 120mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$168.00
$198.24 inclGST -
CTB 70, 70mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s
Hobut CTB 70, 70Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTB 70 Technology Core Balanced/Toroid (CBCT) Aperture Size 70mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$89.00
$105.02 inclGST -
CTB 50, 50mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s
Hobut CTB 50, 50Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTB 50 Technology Core Balanced/Toroid (CBCT) Aperture Size 50mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$72.00
$84.96 inclGST