Trent FGM6DC-3PLC-800 800A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 800 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
25kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PLC-800 800A
Functions
3 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
800 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
25kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-3PLC-800 700A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 700 Amp, 1500VDC, 3 POLE CONNECTING TYPE
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
25kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PLC-800 700A
Functions
3 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
800 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
25kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-3PL-630 630A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 630 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
25kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PLC-630 630A
Functions
3 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
630 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
25kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-3PL-500 500A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 630 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
25kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PLC-630 500A
Functions
3 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
500 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
25kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-3PL-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
25kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PL-400 350A
Functions
3 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
350 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
25kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent FGM6DC-3PL-400 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
3 Pole Disconnect
25kA Short Circuit Rating @1500VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-3PL-400 315A
Functions
3 Pole DC MCCB
Nominal Voltage
1500VDC
Nominal Current Range
315 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
25kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)Â
Weight
8.5kg
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6DC-2P-800 100A, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6DC-2P-800
Functions
Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker Frame size 800
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6DC-2P-630 100A, Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6DC-2P-630
Functions
Terminal Cover for 2 Pole DC Moulded Case Circuit Breaker Frame Size 630
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6DC-3P-800, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 800, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6DC-3P-800
Functions
Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker Frame Size 800
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6DC-630, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 630, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6DC-630
Functions
Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker Frame Size 630
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6DC-400 100A, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 400, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6DC-400
Functions
Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker Frame Size 400
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Trent TC-FGM6DC-250, Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker (MCCB) Frame Size 250, 1 PC ONLYÂ
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
IP40 Terminal Cover
UL94V0 Material
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
TC-FGM6DC-250
Functions
Terminal Cover for 3 Pole DC Moulded Case Circuit Breaker Frame Size 250 or 320Â
Operating Temperature
-25 to 50 Deg C
Insulation Voltage
800V
Weight
50g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet