DC Circuit Breakers
-
TGD-1PL C 25-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 250VDC
TRENT TGD-1PL C 25-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 250VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB,RCM (Pending) Specification TRENT Part Number TGD-1PL C 25-10kA Functions 1 Pole MCB - C Curve Nominal Voltage 250VDC @ 50/60Hz Nominal Current Range 25 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia  Datasheet Product Datasheet
$19.95
$23.54 inclGST -
TGD-2PL C 50-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 500VDC
TRENT TGD-2PL C 50-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 50 Amp, 10kA, 500VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 2 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-2PL C 50-10kA Functions 2 Pole MCB - C Curve Nominal Voltage 500VDC @ 50/60Hz Nominal Current Range 50 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia  Datasheet Product Datasheet
$34.95
$41.24 inclGST -
TGD-2PL C 32-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 32 Amp, 10kA, 500VDC
TRENT TGD-2PL C 32-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 32 Amp, 10kA, 500VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 2 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-2PL C 32-10kA Functions 2 Pole MCB - C Curve Nominal Voltage 500VDC @ 50/60Hz Nominal Current Range 32 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia  Datasheet Product Datasheet
$34.95
$41.24 inclGST -
TGD-2PL C 25-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 500VDC
TRENT TGD-2PL C 25-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 500VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 2 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-2PL C 25-10kA Functions 2 Pole MCB - C Curve Nominal Voltage 500VDC @ 50/60Hz Nominal Current Range 25 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia  Datasheet Product Datasheet
$34.95
$41.24 inclGST -
TGD-2PL C 16-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 16 Amp, 10kA, 500VDC
TRENT TGD-2PL C 16-10kA, 2 Pole Miniature Bidirectional DC Circuit Breaker C Curve 16 Amp, 10kA, 500VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 2 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-2PL C 16-10kA Functions 2 Pole MCB - C Curve Nominal Voltage 500VDC @ 50/60Hz Nominal Current Range 16 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia  Datasheet Product Datasheet
$34.95
$41.24 inclGST -
TGD-1PL C 20-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 20 Amp, 10kA, 250VDC
TRENT TGD-1PL C 20-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 20 Amp, 10kA, 250VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 1 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB,RCM (Pending) Specification TRENT Part Number TGD-1PL C 20-10kA Functions 1 Pole MCB - C Curve Nominal Voltage 250VDC @ 50/60Hz Nominal Current Range 20 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia  Datasheet Product Datasheet
$19.95
$23.54 inclGST -
TGD-4PL C 10-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 10 Amp, 10kA, 1000VDC
TRENT TGD-4PL C 10-10kA, 4 Pole Miniature Bidirectional DC Circuit Breaker C Curve 10 Amp, 10kA, 1000VDC Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 4 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type C, D Curve available Bidirectional Standards : IEC/EN 60898 IEC/EN/AS60898-1 IP20 (IP40 Installed) IEC 61008 CE,CB, RCM (Pending) Specification TRENT Part Number TGD-4PL C 10-10kA Functions 4 Pole MCB - C Curve Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 10 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 6kV Operating Temperature -25 to 40 Deg C Mechanical Operations 10,000 Ops Insulation Voltage 690V Breaking Capacity 10kA Approvals CE,CB, RCM (Pending) Standards IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ; Weight 350g Enclosure Material UL94 Factory Pack Qty 1 TRENT Headquarters Australia  Datasheet Product Datasheet
$59.50
$70.21 inclGST