Hall Effect Voltage Sensors
-
LV100-1000, C/L Voltage Transducer, 1000V, +/-15VDC Aux, 50mA Output
Free Aus Post Shipping for $300 SpendLEM LV 100-1000 C/L Voltage Transducer, 1000V, +/-15VDC Aux, 50mA Output Features Bipolar and insulated voltage measurement up tp 1500VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100-1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary RMS Voltage 1000V Measurement Range +/- 1500 V Output 50 mA Isolation 6 kV Response 40uS Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet
-
LV100-100, C/L Voltage Transducer, 100V, +/-15VDC Aux, 50mA Output
Free Aus Post Shipping for $300 SpendLEM LV 100-100 C/L Voltage Transducer, 100V, +/-15VDC Aux, 50mA Output Features Bipolar and insulated voltage measurement up tp 150VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100-100 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary RMS Voltage 100V Measurement Range +/- 150 V Output 50 mA Isolation 6 kV Response 50uS Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet
-
LV100, C/L Voltage Transducer, 10mA Primary, +/-15VDC Aux, 50mA Output
Free Aus Post Shipping for $300 SpendLV100, C/L Voltage Transducer, 10mA Primary, +/-15VDC Aux, 50mA Output Features Used for Voltage Transducer Design Current input and output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0  Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption  Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications  Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010  Specification LEM Part Number LV 100 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary Nominal Current 10mA Measurement Range +/- 20 mAmp Output 50 mA Isolation 6 kV Response time 20 - 100uS Mounting Style Panel Mount Operating Temperature Range 0°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 460g Factory Pack Quantity 6  Datasheet Product Datasheet
-
DVM 600 Digital Voltage Transducer, Vpn = 600V, +/-12...24VDC, 50mA output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 600 Digital Voltage Transducer, Vpn = 600V, +/-12...24VDC, 50mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-600 Specification LEM Part Number DVM 600 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 600V Measurement Range +/- 900V Output 50 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
-
DVM 4200 Digital Voltage Transducer, Vpn = 4200V, +/-12...24VDC, 72mA output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 4200 Digital Voltage Transducer, Vpn = 4200V, +/-12...24VDC, 50mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-4200 Specification LEM Part Number DVM 4200 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/-4200V Measurement Range +/- 6000V Output 72 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 0.8% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
-
DVM 4000-B Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 6.66V output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 4000-B Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 6.66V output, 12kV Isolation Features Bandwidth DC to 13kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVM 4000-B Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/-4000V Measurement Range +/- 6000V Output 6.66V @ +/- Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw, M5 Inserts on Input Unit Weight 375g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
-
DVM 4000 Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 75mA output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 4000 Digital Voltage Transducer, Vpn = 4000V, +/-12...24VDC, 75mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-4000 Specification LEM Part Number DVM 4000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 4000V Measurement Range +/- 6000V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
-
DVM 3600 Digital Voltage Transducer, Vpn = 3600V, +/-12...24VDC, 75mA output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 3600 Digital Voltage Transducer, Vpn = 3600V, +/-12...24VDC, 75mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-3600 Specification LEM Part Number DVM 3600 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 3600V Measurement Range +/- 5400V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
-
DVM 3000 Digital Voltage Transducer, Vpn = 3000V, +/-12...24VDC, 75mA output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 3000 Digital Voltage Transducer, Vpn = 3000V, +/-12...24VDC, 50mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-3000 Specification LEM Part Number DVM 3000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 3000V Measurement Range +/- 4500V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
-
DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 75mA output, 12kV Isolation
LEM DVM 2000 Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 75mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Drop in Replacment for LV100-2000/SP6 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DVM 2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
$1,078.00
$1,272.04 inclGST -
DVM 1000 Digital Voltage Transducer, Vpn = 1000V, +/-12...24VDC, 75mA output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 1000 Digital Voltage Transducer, Vpn = 1000V, +/-12...24VDC, 75mA output, 12kV Isolation Features Bandwidth DC to 13kHz Closed loop transducer using Hall effect Digital Transducer Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-1000 Specification LEM Part Number DVM 1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 75 mA @Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 375g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
-
DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation
LEM DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 750 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 750V Measurement Range +/- 1125V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
$551.00
$650.18 inclGST