Busbar Mounted Split Core Current Transformers 50x80mm
-
FP040080P/1a G2, 400/1 Amp Split Core CT, Class 0.5 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP040080P/1A, 400/1 Amp Split Core CT, Class 0.5 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP040080P/1A Technology Split Core AC Clip On Current Transformer Ratio 400/5 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 0.5 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FP030080P/1a G2, 300/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP030080P/1A, 300/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP030080P/1A Technology Split Core AC Clip On Current Transformer Ratio 300/1 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FP025080P/1a G2, 250/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP025080P/1A, 250/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP025080P/1A Technology Split Core AC Clip On Current Transformer Ratio 250/1 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FP063080P G2, 630/5 Amp Split Core CT, Class 0.5 3VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP063080P G2, 630/5 Amp Split Core CT, Class 1 3VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP063080P G2 Technology Split Core AC Clip On Current Transformer Ratio 630/5 Aperture Size 53 x 83.5mm VA Rating 3VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 630Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP060080P G2, 600/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP060080P G2, 600/5 Amp Split Core CT, Class 1 3VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP060080P G2 Technology Split Core AC Clip On Current Transformer Ratio 600/5 Aperture Size 53 x 83.5mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 600Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP020080P G2, 200/5 Amp Split Core CT, Class 1 2VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP020080P G2, 200/5 Amp Split Core CT, Class 1 2VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP020080P G2 Technology Split Core AC Clip On Current Transformer Ratio 200/5 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FP025080P G2, 250/5 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP025080P G2, 250/5 Amp Split Core CT, Class 1, 1.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP025080P G2 Technology Split Core AC Clip On Current Transformer Ratio 250/5 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP050080P G2, 500/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP050080P G2, 500/5 Amp Split Core CT, Class 0.5 2.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP050080P G2 Technology Split Core AC Clip On Current Transformer Ratio 500/5 Aperture Size 53 x 83.5mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP030080P G2, 300/5 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP030080P G2, 300/5 Amp Split Core CT, Class 1, 1.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP030080P G2 Technology Split Core AC Clip On Current Transformer Ratio 300/5 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP040080P G2, 400/5 Amp Split Core CT, Class 0.5 1.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP040080P G2, 400/5 Amp Split Core CT, Class 0.5 1.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP040080P G2 Technology Split Core AC Clip On Current Transformer Ratio 400/5 Aperture Size 53 x 83.5mm VA Rating 1.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 400Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP075080P G2, 750/5 Amp Split Core CT, Class 0.5 2.5VA Clip On AC Current Transformer, 53 x 83.5mm Aperture, Dimension 127 x 156 x 36mm
FP075080P G2, 750/5 Amp Split Core CT, Class 1, 2.5VA Series Clip On Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP075080P G2 Technology Split Core AC Clip On Current Transformer Ratio 750/5 Aperture Size 53 x 83.5mm VA Rating 2.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 750Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$102.00
$120.36 inclGST -
FP020080P/66.66mA, 200/66.66mAmp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
FP020080P/66.66mA, 200/66.66mAmp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP020080P/66.66mA Technology Split Core AC Clip On Current Transformer Ratio 200/1 Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 200Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST