all

203 products

  • Rishabh Instruments Split Core AC Current Transformer Xmer CT Split 125/50SC 300/5 Class 1, 50 x 80mm Aperture FE-Xmer CT Split 125/50SC 300/5 Xmer CT Split 125/50SC 300/5 Class 1 3.75VA, 55 x 85mm Aperture

    Xmer CT Split 125/50SC 300/5 Class 1 3.75VA, 55 x 85mm Aperture

    15 pcs in stock

    Xmer CT Split 125/50SC 300/5 Class 1 3.75VA, 55 x 85mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 125/50SC 300/5 Class 1 3.75VA Technology Split Core AC Current Transformer Ratio 300/5 Aperture Size 55 x 85mm VA Rating 3.75VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9 Datasheet Product Datasheet

    15 pcs in stock

    $155.00
    $182.90 inclGST

  • Rishabh Instruments Split Core AC Current Transformer Xmer CT Split 125/50SC 400/5 Class 1, 80 x 50mm Aperture FE-Xmer CT Split 125/50SC 400/5 Xmer CT Split 125/50SC 500/5 Class 1 5VA, 85 x 55mm Aperture

    Xmer CT Split 125/50SC 500/5 Class 1 5VA, 85 x 55mm Aperture

    12 pcs in stock

    Xmer CT Split 125/50SC 500/5 Class 1 5VA, 85 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 125/50SC 500/5 Class 1 5VA Technology Split Core AC Current Transformer Ratio 500/5 Aperture Size 55 x 85mm VA Rating 7.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 500Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9 Datasheet Product Datasheet

    12 pcs in stock

    $155.00
    $182.90 inclGST

  • SCT-F24-100-5A, 5 Amp, 100Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-100-5A, 5 Amp, 100Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F24-200-50mA, 50mA, 200Amp Measurement, Class 1 Split Core CT's

    17 pcs in stock

    Fastron Electronics SCT-F24-200-50mA, 50mA, 200Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F24-200-50mA Technology Split Core AC Current Transformer Ratio 200/50mA Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 50mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    17 pcs in stock

    $50.50
    $59.59 inclGST

  • SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's SCT-F36-500-5A, 5 Amp, 500Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's

    20 pcs in stock

    Fastron Electronics SCT-F36-630-5A, 5 Amp, 630Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F36-630-5A Technology Split Core AC Current Transformer Ratio 630/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 630Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    20 pcs in stock

    $66.50
    $78.47 inclGST

  • SCT-F10-75-1A, 1 Amp Output, 75Amp Measurement, Class 1 Split Core CT's Class 1 SCT-F10-75-1A, 1 Amp Output, 75Amp Measurement, Class 1 Split Core CT's Class 1

    SCT-F10-75-1A, 1 Amp Output, 75Amp Measurement, Class 1 Split Core CT's Class 1

    80 pcs in stock

    Fastron Electronics SCT-F10-75-1A, 1 Amp Output, 75Amp Measurement, Class 1 Split Core CT's Class 1 Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F10-75-1A Technology Split Core AC Current Transformer Ratio 75/1Amp Aperture Size ø 8 mm VA Rating N/A Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 50Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    80 pcs in stock

    $47.30
    $55.81 inclGST

  • SCT-F10-50-1A, 1 Amp Output, 50Amp Measurement, Class 1 Split Core CT's Class 1 SCT-F10-50-1A, 1 Amp Output, 50Amp Measurement, Class 1 Split Core CT's Class 1

    SCT-F10-50-1A, 1 Amp Output, 50Amp Measurement, Class 1 Split Core CT's Class 1

    15 pcs in stock

    Fastron Electronics SCT-F10-50-1A, 1 Amp Output, 50Amp Measurement, Class 1 Split Core CT's Class 1 Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F10-50-1A Technology Split Core AC Current Transformer Ratio 50/1Amp Aperture Size ø 8 mm VA Rating N/A Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 50Amp x 1.2 Termination Style 0.5M Flying Leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    15 pcs in stock

    $47.30
    $55.81 inclGST

  • SCT-F16-10-1A, 10/1Amp Measurement, Class 1 Split Core CT's SCT-F16-10-1A, 10/1Amp Measurement, Class 1 Split Core CT's

    SCT-F16-10-1A, 10/1Amp Measurement, Class 1 Split Core CT's

    43 pcs in stock

    Fastron Electronics SCT-F16-10-1A, 10/1Amp Measurement, Class 1 Split Core Current Transformer Features Quick Release Split Core System Cable Mount 1 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F16-10-1A Technology Split Core AC Current Transformer Ratio 10/1A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 10Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    43 pcs in stock

    $48.00
    $56.64 inclGST

  • FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm

    FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm

    29 pcs in stock

    FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number FP080080P Technology Split Core AC Clip On Current Transformer Ratio 800/5 Aperture Size 50 x 80mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1   Datasheet Product Datasheet Installation Guide  

    29 pcs in stock

    $102.00
    $120.36 inclGST

  • SCT-F50-100, 0.333V, 100Amp measurement Split Core CT's SCT-F50-100, 0.333V, 100Amp measurement Split Core CT's

    SCT-F50-100, 0.333V, 100Amp measurement Split Core CT's

    30 pcs in stock

    Fastron Electronics SCT-F50-100, 0.333V, 100Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-100 Technology Split Core AC Current Transformer Ratio 100/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    30 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's

    SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's

    24 pcs in stock

    Fastron Electronics SCT-F50-200, 0.333V, 200Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-200 Technology Split Core AC Current Transformer Ratio 200/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 200g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    24 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F50-250, 0.333V, 250Amp measurement Split Core CT's SCT-F50-250, 0.333V, 250Amp measurement Split Core CT's

    SCT-F50-250, 0.333V, 250Amp measurement Split Core CT's

    39 pcs in stock

    Fastron Electronics SCT-F50-250, 0.333V, 250Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-250 Technology Split Core AC Current Transformer Ratio 250/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    39 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F50-300, 0.333V, 300Amp measurement Split Core CT's SCT-F50-300, 0.333V, 300Amp measurement Split Core CT's

    SCT-F50-300, 0.333V, 300Amp measurement Split Core CT's

    27 pcs in stock

    Fastron Electronics SCT-F50-300, 0.333V, 300Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-300 Technology Split Core AC Current Transformer Ratio 300/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 300g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    27 pcs in stock

    $110.55
    $130.45 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account