Fastron Electronics FGC3-D323, Star-Delta Reduced Voltage starter, 240/400/500/690V, Nominal Current = 32 Amps (AC-3), 50/60Hz Operation, 230VAC Coil Voltage, 3 Pole 3 x NO + 1NO
Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
CE, CB Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Electronics Part Number
FGC3-D323
Functions
3 Pole NO + 1NO 1NC Contactor
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
32 Amp Continuous @ 55 Deg C
Main Contacts
3 x NO
Auxiliary Contacts
1 x NO
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
2.3W
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
900g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics FGC2-D32-230VAC, Interlocking AC Contactor / Motor Reverser, 240VAC Control Voltage, 3 Pole 3 x NO , 3 x NC + 1NO1NC Aux, Nominal Current = 32 Amps(AC-3) @ 240/400/500/690V
Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
CE, CB Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Fastron Electronics Part Number
FGC2-D32-230VAC
Functions
3 Pole (x2) + 1NO 1NC Contactor
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
32 Amp Continuous @ 55 Deg C
Main Contacts
3 x NO, 3 x NC
Auxiliary Contacts
1 x NO, 1 x NC
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
240VAC
Power Dissipation
2.3W
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
600g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Gigavac GXV600P, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC EXTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
12/24VDC Internal or External PWM Coils
Flexible package for installation
Specification
Gigavac Part Number
GXV600P
Main Contact Type
SPST-NO
Auxiliary Contact Type
None
Coil Voltage
12/24VDC External PWM
Load Current
600+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
JST Connector: 02CPT-B-2A JST Terminal: SCPT-A021GF-0.5
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 900VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Gigavac GXV600M, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC INTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
12/24VDC Internal or External PWM Coils
Flexible package for installation
Specification
Gigavac Part Number
GXV600M
Main Contact Type
SPST-NO
Auxiliary Contact Type
None
Coil Voltage
12/24VDC Internal PWM
Load Current
600+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
JST Connector: 02CPT-B-2A JST Terminal: SCPT-A021GF-0.5
Special Feature
N/A
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 900VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom DRC3R40E420, AC Motor Controller & Contactor, 7.6 Amp, 18-30VDC control, 48-530VAC Load, 2 Solid State NO Aux Contacts, Zero Crossing
Features
7.6 Amp AC Semiconductor Motor Controller
Load voltage range up to 600VAC
Fits standard 35mm DIN Rail
LED input status indicator
AC or DC control
Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Built-in Overvoltage Protection
Ultra-efficient thermal management design (Patented)
Spec
Crydom Part Number
DRC3R40E420
Switching Type
DC Load
Approvals
ROHS,UL,CE,IEC
Control Voltage
18-30VDC
Load Current
7.6 Amp (rms)
Surge Capability (10ms)
716 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48-440VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
197g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
DR6760DR75P, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, Random Crossing, 75 Amp per phase @ 40 Deg C, 48-600VAC Load, LED Status Indicator, Overvoltage Protection
Features
Ratings from 60A to 75 Amp @ 70-530 VAC
Motor Control
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DR6760DR75P
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 75 Amp (rms) per Phase @ 30 DeG C
Surge Capability
1290 Amp (peak)
Special Feature
LED Status Indicator, Overvoltage Protection
Mounting Style
Din Rail Mount
Load Voltage Range
48-600VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
961g
Factory Pack Qty
10
Datasheet
DR6760D75P
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Crydom DRA4D100D12, DC Motor Reversing Contactor, 12 Amp, 3-15VDC control, 100VDC Load
Features
12 Amp DC Semiconductor Motor Controller
Load voltage range up to 250VDC
Optional Start/Stop Ramp/Break
Panel Mount
LED Forward and Reverse input status indicator
15-32VDC or 4.5-15VDC control
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Spec
Crydom Part Number
DRA4D100D12
Switching Type
DC Load
Approvals
ROHS,UL,CE,IEC
Control Voltage
3-15VDC
Load Current
12 Amp DC
Surge Capability (10ms)
110 Amp DC
Special Feature
FWD and REV LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
350g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Gigavac GV200NAB-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 48VDC PWM Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67
Features
PWM Rated Coil
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV200NAB-1
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
48VDC (PWM)
Load Current
500+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
PWM Rated Coil
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Crydom DRA4D100E12, DC Motor Reversing Contactor, 12 Amp, 15-32VDC control, 100VDC Load
Features
12 Amp DC Semiconductor Motor Controller
Load voltage range up to 200VDC
Optional Start/Stop Ramp/Break
Panel Mount
LED Forward and Reverse input status indicator
15-32VDC or 4.5-15VDC control
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Spec
Crydom Part Number
DRA4D100E12
Switching Type
DC Load
Approvals
ROHS,UL,CE,IEC
Control Voltage
15-32VDC
Load Current
12 Amp DC
Surge Capability (10ms)
110 Amp DC
Special Feature
FWD and REV LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
350g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DP4RSB60E40B5, DC Motor Reversing Contactor, 40 Amp, 18-32VDC control, 48VDC Load, 0.2s Soft Start, 0.5s Dynamic Brake
Features
40 Amp DC Semiconductor Motor Controller
Load voltage range up to 48VDC
Optional Start/Stop Ramp/Break
Panel Mount
LED Forward and Reverse input status indicator
18-32VDC or 4.5-15VDC control
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Spec
Crydom Part Number
DP4RSB60E40B5
Switching Type
DC Load
Approvals
ROHS,UL,CE,IEC
Control Voltage
18-32VDC
Load Current
40 Amp DC
Surge Capability (10ms)
140 Amp DC
Special Feature
FWD and REV LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
350g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Gigavac GV200MA-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 12/24VDC PWM Coil
Features
PWM Rated Coil
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV200MA-1
Main Contact Type
SPST-NO
Auxiliary Contact Type
None
Coil Voltage
12/24VDC (PWM)
Load Current
500+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
PWM Rated Coil
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Gigavac GV141MAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 12/24VDC PWM Coil
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Giagavac Part Number
GV141MAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
12/24VAC/DC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
PWM Rated Coil
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 100VDC
Standards
CE, UL1604, IP67, SAEJ1171
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet