Motor Contactors, Interlocked Contactors, and Motor Reversers

16 products

  • FGC3-D323, Star-Delta Reduced Voltage starter, 240/400/500/690V, Nominal Current = 32 Amps (AC-3), 50/60Hz Operation, 230VAC Coil Voltage, 3 Pole 3 x NO + 1NO

    FGC3-D323, Star-Delta Reduced Voltage starter, 240/400/500/690V, Nominal Current = 32 Amps (AC-3), 50/60Hz Operation, 230VAC Coil Voltage, 3 Pole 3 x NO + 1NO

    Out of stock

    Fastron Electronics FGC3-D323, Star-Delta Reduced Voltage starter, 240/400/500/690V, Nominal Current = 32 Amps (AC-3), 50/60Hz Operation, 230VAC Coil Voltage, 3 Pole 3 x NO + 1NO Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp CE, CB Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Fastron Electronics Part Number FGC3-D323 Functions 3 Pole NO + 1NO 1NC Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 32 Amp Continuous @ 55 Deg C Main Contacts 3 x NO Auxiliary Contacts 1 x NO Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 2.3W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 900g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $398.00
    $469.64 inclGST

  • FGC2-D32-230VAC, Interlocking AC Contactor / Motor Reverser, 240VAC Control Voltage, 3 Pole 3 x NO , 3 x NC + 1NO1NC Aux, Nominal Current = 32 Amps(AC-3) @ 240/400/500/690V

    FGC2-D32-230VAC, Interlocking AC Contactor / Motor Reverser, 240VAC Control Voltage, 3 Pole 3 x NO , 3 x NC + 1NO1NC Aux, Nominal Current = 32 Amps(AC-3) @ 240/400/500/690V

    298 pcs in stock

    Fastron Electronics FGC2-D32-230VAC, Interlocking AC Contactor / Motor Reverser, 240VAC Control Voltage, 3 Pole 3 x NO , 3 x NC + 1NO1NC Aux, Nominal Current = 32 Amps(AC-3) @ 240/400/500/690V Contactors are designed to meet the requirements of heavy Duty applications. Contactors may be fitted with auxiliary contacts. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp CE, CB Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Fastron Electronics Part Number FGC2-D32-230VAC Functions 3 Pole (x2) + 1NO 1NC Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 32 Amp Continuous @ 55 Deg C Main Contacts 3 x NO, 3 x NC Auxiliary Contacts 1 x NO, 1 x NC Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 2.3W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 600g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    298 pcs in stock

    $398.00
    $469.64 inclGST

  • GXV600P, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC EXTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67

    GXV600P, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC EXTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67

    Out of stock

    Gigavac GXV600P, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC EXTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved 12/24VDC Internal or External PWM Coils Flexible package for installation Specification Gigavac Part Number GXV600P Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 12/24VDC External PWM Load Current 600+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals JST Connector: 02CPT-B-2A JST Terminal: SCPT-A021GF-0.5 Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 12 - 900VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $369.00
    $435.42 inclGST

  • GXV600M, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC INTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67

    GXV600M, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC INTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67

    Out of stock

    Gigavac GXV600M, Contactor SPST-NO, 600+ AMP, 12-900VDC, 12/24VDC INTERNAL PWM Coil, Coil Termination to SCPT-A021GF-0.5, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved 12/24VDC Internal or External PWM Coils Flexible package for installation Specification Gigavac Part Number GXV600M Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 12/24VDC Internal PWM Load Current 600+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals JST Connector: 02CPT-B-2A JST Terminal: SCPT-A021GF-0.5 Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 12 - 900VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $369.00
    $435.42 inclGST

  • DRC3R40E420, AC Motor Controller & Contactor, 7.6 Amp, 18-30VDC control, 48-440VAC Load, 2 Solid State NO Aux Contacts, Zero Crossing

    DRC3R40E420, AC Motor Controller & Contactor, 7.6 Amp, 18-30VDC control, 48-440VAC Load, 2 Solid State NO Aux Contacts, Zero Crossing

    Out of stock

    Crydom DRC3R40E420, AC Motor Controller & Contactor, 7.6 Amp, 18-30VDC control, 48-530VAC Load, 2 Solid State NO Aux Contacts, Zero Crossing Features 7.6 Amp AC Semiconductor Motor Controller Load voltage range up to 600VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Spec Crydom Part Number DRC3R40E420 Switching Type DC Load Approvals ROHS,UL,CE,IEC Control Voltage 18-30VDC Load Current 7.6 Amp (rms) Surge Capability (10ms) 716 Amp (peak) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48-440VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 197g Factory Pack Qty 20   Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies

    Out of stock

    $347.28
    $409.79 inclGST

  • DR6760DR75P, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, Random Crossing, 75 Amp per phase @ 40 Deg C, 48-600VAC Load, LED Status Indicator, Overvoltage Protection

    DR6760DR75P, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, Random Crossing, 75 Amp per phase @ 40 Deg C, 48-600VAC Load, LED Status Indicator, Overvoltage Protection

    Out of stock

    DR6760DR75P, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, Random Crossing, 75 Amp per phase @ 40 Deg C, 48-600VAC Load, LED Status Indicator, Overvoltage Protection Features Ratings from 60A to 75 Amp @ 70-530 VAC Motor Control SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number DR6760DR75P Switching Type Random Crossing ROHS/CE/UL Yes Control Voltage 4-32VDC Load Current 3 x 75 Amp (rms) per Phase @ 30 DeG C Surge Capability 1290 Amp (peak) Special Feature LED Status Indicator, Overvoltage Protection Mounting Style Din Rail Mount Load Voltage Range 48-600VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 961g Factory Pack Qty 10   Datasheet DR6760D75P 3 Phase SSR and Heatsink Mounted   App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement

    Out of stock

    $655.00
    $772.90 inclGST

  • DRA4D100D12, DC Motor Reversing Contactor, 12 Amp, 4.5-15VDC control, 100VDC Load

    DRA4D100D12, DC Motor Reversing Contactor, 12 Amp, 4.5-15VDC control, 100VDC Load

    Out of stock

    Crydom DRA4D100D12, DC Motor Reversing Contactor, 12 Amp, 3-15VDC control, 100VDC Load Features 12 Amp DC Semiconductor Motor Controller Load voltage range up to 250VDC Optional Start/Stop Ramp/Break Panel Mount LED Forward and Reverse input status indicator 15-32VDC or 4.5-15VDC control C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Spec Crydom Part Number DRA4D100D12 Switching Type DC Load Approvals ROHS,UL,CE,IEC Control Voltage 3-15VDC Load Current 12 Amp DC Surge Capability (10ms) 110 Amp DC Special Feature FWD and REV LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 350g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies

    Out of stock

    $540.39
    $637.66 inclGST

  • GV200NAB-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 48VDC PWM Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67

    GV200NAB-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 48VDC PWM Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67

    Out of stock

    Gigavac GV200NAB-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 48VDC PWM Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67 Features PWM Rated Coil Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV200NAB-1 Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 48VDC (PWM) Load Current 500+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature PWM Rated Coil Mounting Style Panel Mount (M5) Load Voltage Range 12 - 800VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet

    Out of stock

    $283.80
    $334.88 inclGST

  • DRA4D100E12, DC Motor Reversing Contactor, 12 Amp, 15-32VDC control, 100VDC Load

    DRA4D100E12, DC Motor Reversing Contactor, 12 Amp, 15-32VDC control, 100VDC Load

    Out of stock

    Crydom DRA4D100E12, DC Motor Reversing Contactor, 12 Amp, 15-32VDC control, 100VDC Load Features 12 Amp DC Semiconductor Motor Controller Load voltage range up to 200VDC Optional Start/Stop Ramp/Break Panel Mount LED Forward and Reverse input status indicator 15-32VDC or 4.5-15VDC control C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Spec Crydom Part Number DRA4D100E12 Switching Type DC Load Approvals ROHS,UL,CE,IEC Control Voltage 15-32VDC Load Current 12 Amp DC Surge Capability (10ms) 110 Amp DC Special Feature FWD and REV LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 350g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies

    Out of stock

    $507.78
    $599.18 inclGST

  • Last stock! DP4RSB60E40B5, DC Motor Reversing Contactor, 40 Amp, 18-32VDC control, 48VDC Load, 0.2s Soft Start, 0.5s Dynamic Brake

    DP4RSB60E40B5, DC Motor Reversing Contactor, 40 Amp, 18-32VDC control, 48VDC Load, 0.2s Soft Start, 0.5s Dynamic Brake

    5 pcs in stock

    Crydom DP4RSB60E40B5, DC Motor Reversing Contactor, 40 Amp, 18-32VDC control, 48VDC Load, 0.2s Soft Start, 0.5s Dynamic Brake Features 40 Amp DC Semiconductor Motor Controller Load voltage range up to 48VDC Optional Start/Stop Ramp/Break Panel Mount LED Forward and Reverse input status indicator 18-32VDC or 4.5-15VDC control C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Spec Crydom Part Number DP4RSB60E40B5 Switching Type DC Load Approvals ROHS,UL,CE,IEC Control Voltage 18-32VDC Load Current 40 Amp DC Surge Capability (10ms) 140 Amp DC Special Feature FWD and REV LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 350g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies

    5 pcs in stock

    $742.96
    $876.69 inclGST

  • Last stock! GV200MA-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 12/24VDC PWM Coil, 38cm Flying leads, WITHOUT Auxiliary Contact, IP67

    GV200MA-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 12/24VDC PWM Coil, 38cm Flying leads, WITHOUT Auxiliary Contact, IP67

    1 pcs in stock

    Gigavac GV200MA-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 12/24VDC PWM Coil Features PWM Rated Coil Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV200MA-1 Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 12/24VDC (PWM) Load Current 500+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature PWM Rated Coil Mounting Style Panel Mount (M5) Load Voltage Range 12 - 800VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet

    1 pcs in stock

    $279.86
    $330.23 inclGST

  • GV141MAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 12/24VDC PWM Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67

    GV141MAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 12/24VDC PWM Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67

    Out of stock

    Gigavac GV141MAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 12/24VDC PWM Coil Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Giagavac Part Number GV141MAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 12/24VAC/DC Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature PWM Rated Coil Mounting Style Panel Mount (M5) Load Voltage Range 12 - 100VDC Standards CE, UL1604, IP67, SAEJ1171 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet

    Out of stock

    $240.90
    $284.26 inclGST