Fastron Electronics SCT-F24-100-0.2V, 200mV, 100Amp Measurement Class 1 Split Core CT's for Power Quality Analysers 2mV/Amp
Features
Quick Release Split Core System
Cable Mount
200mV Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-100-0.2V
Technology
Split Core AC Current Transformer
Ratio
100/200mV
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
200mV (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics SCT-F10-50-0.2V, 200mV, 50Amp measurement Split Core CT's Class 1 with 0.5M flying leads
Features
Quick Release Split Core System
Cable Mount
200mV Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F10-50-0.2V
Technology
Split Core AC Current Transformer
Ratio
50/200mV
Aperture Size
ø 10 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
200mV (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
50Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics SCT-F10-20-0.2V, 200mV, 20Amp measurement Split Core CT's Class 1 with 0.5M flying leads
Features
Quick Release Split Core System
Cable Mount
200mV Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F10-20-0.2V
Technology
Split Core AC Current Transformer
Ratio
20/200mV
Aperture Size
ø 10 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
200mV (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
20Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
PR 1200 MAC1 Current Clamp 1200Amp AC, 1A = 1mA Output
Datasheet
Product Datasheet
, Obsolete. See Northern Design for possible alternative Current Clamps. Price on request
Northern Design P32 1000,2000,3000A / 1V, 1000,2000,3000 Amp AC Current Clamp 1VDC Conditioned Output, 83mm Diameter
Other Ratings available on request. See Current Clamps (AC and DC)
Specimen Datasheet (not exact spec)
Datasheet
Product Datasheet
Northern Design S.1200:5A, 1200 Amp AC Current Clamp 5 Amp AC Output, 50mm Diameter
Other Ratings available on request. See Current Clamps (AC and DC)
Specimen Datasheet (not exact Spec)
Datasheet
Product Datasheet
Northern Design P32 2000:5A, 2000 Amp AC Current Clamp 5Amp AC Output, 83mm Diameter
Other Ratings available on request. See Current Clamps (AC and DC)
Specimen Datasheet (not exact spec)
Datasheet
Product Datasheet
Northern Design H32 30,300,3000A / 1V, 30,300,3000 Amp AC Current Clamp 1VDC rms Conditioned Output, 50mm Diameter
Other Ratings available on request. See Current Clamps (AC and DC)
Datasheet
Product Datasheet
M4 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 600V for Busbar/Bare Wire
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
600V Insulation (3kv/1min)
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M4.10.2mA,M4.100.0.1V,M4.100.100mA,M4.100.1A,M4.100.1V,
M4.200.1A,M4.200.2V,M4.UM.1A.1V,M4.UM.50A.1V,M4.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
600V (rms) Non-Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
M2 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 30V Bare copper, (or 600V insulated cables)
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
600V Insulation (3kv/1min) [Bare bar/wire)
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M2.10.2mA,M2.100.0.1V,M2.100.100mA,M2.100.1A,M2.100.1V,
M2.200.1A,M2.200.2V,M2.UM.1A.1V,M2.UM.50A.1V,M2.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
30V (rms) Bare Copper, 600V (rms) Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
M3 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 600V (For Non Insulated Busbar or wire)
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
For Non Insulated or Insulated Busbar/ Bare Wire
Rated System Voltage 0.6/3kV (1 Min) NOTE: 30V only with Non Insulated cables, see M2 for 600V Insulated types.
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M3.10.2mA,M3.100.0.1V,M3.100.100mA,M3.100.1A,M3.100.1V,
M3.200.1A,M3.200.2V,M3.UM.1A.1V,M3.UM.50A.1V,M3.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
600V (rms) Non-Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz (customised on request)
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
Northern Design S.UM3 10,100,1000A / 1V, 10,100,1000 Amp AC Current Clamp 1VAC Output, 50mm Diameter
Other Ratings available on request. See Current Clamps (AC and DC)
Datasheet
Product Datasheet