Current Transformers Australia
-
SCT-F24-100-5A, 5 Amp, 100Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F24-100, 100/5 Amp Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F24-100-5A Technology Split Core AC Current Transformer Ratio 100/5 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$44.20
$52.16 inclGST -
SCT-F36-400-5A, 5 Amp, 400Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-400-5A, 5 Amp, 400Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F36-400-5A Technology Split Core AC Current Transformer Ratio 400/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9  Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F24-200-5A, 5 Amp, 200Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F24-200-5A, 200/5 Amp Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F24-200-5A Technology Split Core AC Current Transformer Ratio 200/5 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$44.20
$52.16 inclGST -
SCT-F16-100-5A, 100/5Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F16-100-5A, 5 Amp Output, 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F16-100-5A Technology Split Core AC Current Transformer Ratio 100/5A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$45.00
$53.10 inclGST -
SCT-F24-250-5A, 5 Amp, 250Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F24-250 250/5 Amp Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F24-250-5A Technology Split Core AC Current Transformer Ratio 250/5 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$44.20
$52.16 inclGST -
SCT-F50-400-5A, 5 Amp, 400Amp measurement Split Core CT's
Fastron Electronics SCT-F50-400-5A, 5 Amp, 400Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F50-400-5A Technology Split Core AC Current Transformer Ratio 400/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9  Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F24-300-5A, 5 Amp, 300Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F24-300-5A, 300/5 Amp Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F24-300-5A Technology Split Core AC Current Transformer Ratio 300/5 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$44.20
$52.16 inclGST -
SCT-F36-250-5A, 5 Amp, 250Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F36-250-5A, 5 Amp, 250Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-250-5A Technology Split Core AC Current Transformer Ratio 250/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F50-800-5A, 5 Amp, 800Amp measurement Split Core CT's
Fastron Electronics SCT-F50-800-5A, 5 Amp, 800Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F50-800-5A Technology Split Core AC Current Transformer Ratio 800/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 800Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9  Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F24-150-5A, 5 Amp, 150Amp Measurement, Class 1 Split Core CT's
Fastron Electronics SCT-F24-150 Amp, 5 Amp Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F24-150-5A Technology Split Core AC Current Transformer Ratio 150/5 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9  Datasheet Product Datasheet Application Notes Installation Guide
$44.20
$52.16 inclGST -
FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
FP080080P, 800/5 Amp Split Core CT, Class 0.5, 2.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number FP080080P Technology Split Core AC Clip On Current Transformer Ratio 800/5 Aperture Size 50 x 80mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 800Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1  Datasheet Product Datasheet Installation Guide Â
$102.00
$120.36 inclGST -
SCT-F50-600-5A, 5 Amp, 600Amp measurement Split Core CT's
Fastron Electronics SCT-F50-600-5A, 5 Amp, 600Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements  Specification Fastron Part Number SCT-F50-600-5A Technology Split Core AC Current Transformer Ratio 600/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9  Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST